Skip to search Skip to main content Skip to navigation

Singapore 1800 622 1156 | Intl +65 6415 5353 | Welcome to our new site - found a bug? Please report it here

We noticed you are in , please visit your local site by clicking the below link for regional offers and support.
Back To Top

DIN Rail Signal Conditioners

35 Products
DIN Rail Conditioners Convert Bridge Inputs to mA or Voltage

The DMD4059 Series converts wheatstone strain bridge sensors, pressure transducers, or load cell signals into process current or voltage. Offered with AC or DC Power.

DIN Rail Universal Uni/Bipolar DC Signal Conditioner

The DRST-DC measures unipolar or bipolar DC current and voltage signals. Passive/active current buffered output voltage. Additional programmer required.

Dual DIN Rail Temperature Transmitter w/ Programmable Inputs

The TXDIN70 series provide two channel transmitters or isolators with 4-20 or 0-20 mA output. Programmable input types with TXDIN70-DISPLAY accessory (sold separately)

DIN Rail Frequency Input Signal Conditioner | Configurable

The DRST-FR converts frequency/pulse inputs to a 4-20mA or 0-10V DC output. PNP/NPN output, relay output. Universal power supply. Configurable with TXUN-KIT device.

DIN Rail Thermocouple Input Signal Conditioners | Low Profile

The DRSL-TC Series are isolated or non-isolated thermocouple input signal conditioners. Accepts Type J and Type K TC's. DIP switch selectable ranges, slim housing.

DIN Rail RTD Input Signal Conditioner | Low Profile

The DRSL-RTD is either isolated or non-isolated with 2, 3, or 4-wire Pt100 RTD input. Pre-calibrated temp ranges selectable via DIP switch. Slim housing, high accuracy.

Snap In Front Panel Programmer with Modbus over RS-485

The DRST-CM is a programming display for DRST-AC, DRST-DC, DRST-UN & DRST-UR. Supports Modbus over RS-485. Monitors process value on built in display.

DIN Rail DC Current Signal Splitters w/ Dual Output

The DRSP-I Series are DC current splitters that take one 4-20mA input to two 4-20mA outputs w/ AC or DC power. Zero and span adjustments for each output, status LEDs.

DIN Rail Strain Gage/Load Cell Transmitter w/ Bipolar mA/V Output

TXDIN1600S strain gage/load cell transmitter accepts 0.2 to 7.5 mV/V inputs with 5V excitation. Universal current, bipolar voltage output. Remote tare, front panel config.

DIN Rail Universal Input Transmitter with Push Button User Trim

TXDIN1600 series has a universal thermocouple, RTD, or process input and 4-20mA output. Configuration via USB cable (sold separately). Push button user trim, relay output

DIN Rail Isolated Repeater/Splitter for Current Signals

The DRSL-SP1 is a repeater/splitter that isolates and converts 1 current input to 2 current outputs. Slim housing, high accuracy (0.05%), no setup needed.

DIN Rail Loop Powered RTD Input Signal Conditioner

The DRA-RTT-2 is a DIN Rail loop powered signal conditioner with RTD input and 4-20mA linearized output. It has ± 0.1% accuracy and is field rangeable and low cost.

DIN Rail Conditioner Series with Process Input, High accuracy

The DRSL-DC1-DC2 Conditioners have a DC current and voltage input and isolated and converted DC current and voltage output. DIP switch selectable range. 0.05% accuracy

DIN Rail Signal Conditioner for AC LVDT Transducers

The LDX-D is a DIN rail mount AC LVDT transducer that operates on 10-30Vdc power with selectable process outputs. Adjustable signal polarity, span, and offset.

DIN Rail Field Configurable Alarm Limit Modules

The DRG-AR Series Conditioners are TC, RTC, DC or AC voltage and current input with 2 SPDT Relay Outputs. Field configurable ranges with adjustable setpoints.

DIN Rail Signal Conditioner Series with Model Specific Input Type

CCT DIN rail conditioners that accept various input signals, such as voltage and current, frequency, temperature (TC and RTD), and provide 0/4 to 20 mA, or 0 to 10 Vdc.

DIN Rail 2 Wire Temperature Signal Conditioners/Transmitters

The DRA-TCI-RTI Series are 2 wire Temperature Signal Conditioners/Transmitters. There are TC and RTD input models with 4-20mA output. They are isolated and field rangeable

DIN Rail AC Current and Voltage Transmitter

The DRST-AC measures AC current or voltage signals and outputs passive or active current signals. UL and c-UL approved. Universal power. Programmer required.

DIN Rail Signal Conditioners

DIN Rail Signal Conditioners support data acquisition workflows by helping users measure, condition, record, transmit, or review field information. Products in this category span DIN rail signal conditioners for temperature, voltage, current, frequency, process transducer, bridge, strain gage, load cell, mA, voltage, and RS-485 applications.

Applications include control panel signal conversion, sensor-to-PC acquisition, PLC inputs, bridge and load-cell signal transmission, process monitoring, and retrofit work where DIN rail mounting is preferred. Products represented in the source data include Omega Engineering.

Applications include:

  • Convert raw sensor or process inputs
  • Provide mA, voltage, or RS-485 outputs
  • Mount devices in DIN rail control panels
  • Condition bridge, strain gage, and load-cell signals
  • Interface field sensors with controllers or acquisition systems
Searching for your items
en-SG
en_SG
Save Configuration
-->