Models In Stock
- Directly Connects to Thermocouple, RTD, Thermistor, Strain Gage, Load Cell, Voltage, Current, Resistance and Accelerometer Inputs
- Expandable to over 1000 Channels
- Analog and Digital Input and Outputs
- Free instruNet World Software
iNET-400-500-Series
From
SGD
3,799.61
Models In Stock
Product Overview
- Analog I/O Note Analog: No. of Channels: iNET-430: 16 single-ended (SE)/ 8 differential (DI), A/D Converter: 16-bit (iNET-430 only), Common Mode Voltage: ±10 Vdc (iNET-420 and iNET-430), Crosstalk: < -80 dB typical, Input Impedance: 100 MΩ, Digital I/O (iNET-430): No. of Channels: 4 universal digital I/O (20 mA sink, -10 to 30V), Working Voltage: -10 to 30 Vdc: “0” Input Voltage: -10 to 0.65V, “0” Input Current: Amps = (4.5V – Vin)/3900, “1” Input Voltage: 2.1 to 30 Vdc, “1” Input Current: <1.4 mA, “0” Output Voltage: <0.8V @ < 5 mA; < 2V @ <20 mA, “1” Output Voltage: 3.9 to 4.5V, “1” Output Current: See "1" input current, Pull-Up Resistor: 3.9 kΩ±10%, Schmitt Trigger Input: Yes
- Common Mode Voltage ±10 Vdc
- Current Drive ±4 mA
- Current Measurement Range ±80 uA, ±120 uA, ±500 uA, ±600 uA, ±800 uA, ±1.2 mA, ±2.5 mA, ±12 mA, ±24 mA, 0 to 24 mA
- Data Interface USB
- Data Interface Note InstruNet Software;Data Acquisition Hardware for Windows ≥ XP SP2, Vista 7 or 8 (XP/VS/7/8)
- Digital Input Digital: Low = –10 to 0.65 Vdc Low Current = (4.5 V – Vin)/3900
- Digital I/O Note Cross Talk : 80 dB
- Digital Output Digital: “0” Output Voltage: <0.8V @ < 5 mA; < 2V @ <20 mA, “1” Output Voltage: 3.9 to 4.5V, “1” Output Current: <1.4 mA
- Height 14 mm
- Impedance Input 100 MΩ
- Input Type Voltage, Thermocouple, Thermistor, RTD, Load Cell, Strain, Potentiometer, Current, Resistance, Flow, Pressure, Digital
- Length 15 mm
- Materials Aluminum
- Mounting Place on Desktop, Affix to DIN-Rail, 19" Rack, or Wall Mount
- Number of Channels, Input Analog: 8 DIFF/16 SE, Digital: 4
- Number of Channels, Output Precision Analog Voltage: 2, Analog Voltage: 2, Digital: 4
- Number of Slots 4
- Operating Temperature, Max 45 °C
- Operating Temperature, Min 1 °C
- Output Resolution Precision Analog Voltage: 14-bit, Analog Voltage: 8-bit
- Output Signal Voltage, Digital
- Pull-up Resistor 3.9 kΩ±10%
- Relative Humidity <90% RH
- Resistance Measurement Range 10 kΩ Pot, 50 kΩ Pot, 0 to 33 Ω, 0 to 100 Ω, 0 to 330 Ω, 0 to 1 kΩ, 0 to 3300 Ω, 0 to 10 kΩ
- Sampling Rate 166 kHz (166,000 updates/second)
- Sensor Type Thermocouple Type J, K, T, E, R, S, B, N, C, G, D, 100 Ω RTD, 500 Ω RTD, 1 kΩ RTD, 2252 Ω Thermistor
- Series ID iNET-400-500-Series
- Storage Temperature, Max 70 °C
- Storage Temperature, Min -20 °C
- Supply Power Type DC
- Supply Voltage ± 5 Vdc, ± 12 Vdc
- Temperature Measurement Range TEMP LABEL 2 To be Updated
- Voltage Measurement Range ±10V, ± 5V, ± 2.5V, ± 1.2V, ± 600 mV, ± 300 mV, ± 80 mV, ± 40 mV, ± 20 mV, ± 10 mV, ± 5 mV, 0 to 10V, 0 to 5V, 0 to 2.5V, 0 to 1.2V, 0 to 80 mV, 0 to 40mV
- Width 11 mm
Supported Applications
The Omega iNET-400 Series is an expandable modular data acquisition system designed for multi-channel measurement of voltage, current, resistance, thermocouple, RTD, thermistor, strain gage, load cell, potentiometer, accelerometer, and counter/timer signals. The series connects to Windows computers via the iNET-240 USB 2.0 controller, enabling digitization of any combination of channels at an aggregate rate up to 166,000 samples per second.
Applications include laboratory testing and industrial monitoring where universal-input measurement modules connect directly to sensors. The system supports software interfaces including instruNet World Plus (iNET-iWPLUS), LabVIEW drivers (iNET-380 for versions ≥4), DASYLab, Visual Basic, C/C++, and Excel.
Operating Conditions & Performance
The iNET-400 Series operates within an ambient temperature range of 1 to 45°C (34 to 113°F) with humidity below 90% RH. Storage temperatures are rated from -20 to 70°C (-4 to 158°F). The system utilizes a USB 2.0 high-speed connection (480Mbaud) between the computer and iNET-240 controller, extending via DB25 male/female cables in a daisy-chain configuration up to 300 meters with an instruNet terminator at the far end.
Performance specifications vary by card model:
- iNET-430: Features a 16-bit A/D converter. Voltage accuracy for the ±5V range is specified as ±(0.010% + 332.7µV) with 1 ms averaging.
- Thermocouple Accuracy (iNET-430): Type J ranges from 0 to 750°C at ±1°C; Type K ranges from -200 to 1250°C at ±1.2°C.
- RTD Accuracy: For a 1,000 Ω RTD in the range of -100 to 300°C, accuracy is ±0.8°C on iNET-430 (requires OMEGA 10 kΩ shunt resistor iNET-R-10K).
- Thermistor Accuracy: For a 2252 Ω thermistor in the range of 0 to 100°C, accuracy is ±0.47°C on iNET-430 (requires OMEGA 10 kΩ shunt resistor iNET-R-10K).
Each channel supports independently programmable analog filters, integration time, voltage range, and sample rate, plus programmable digital filters (LP, HP, BP, BS). The system requires +5 Vdc and ±12 Vdc power supplied by the iNET-312-8 desktop power supply.
Configuration Options
The series is built around a 4-slot card cage (iNET-400) constructed of solid aluminum, which can be expanded to 8, 12, or 16 slots by bolting cages side-by-side. The iNET-410 interface card must occupy slot #1 in each cage.
Available measurement and I/O cards include:
- iNET-420: Provides 20 single-ended/10 differential voltage inputs (±10V to ±20mV) with a multiplexer, plus 4 digital I/O channels.
- iNET-423: Offers 6 differential voltage inputs with amplifier and filter capabilities; gain is software selectable at 1 or 64. Supports up to six iNET-500 analog low pass Butterworth filter daughter boards (one per channel) with cutoff frequencies of 380 Hz, 1 kHz, 3300 Hz, or 10 kHz.
- iNET-430: Includes a 16-bit A/D converter for voltage inputs (±10V to ±10mV), two precision analog voltage outputs (±10.1V, 14-bit D/A) or two unipolar outputs (0 to 10.1V, 8-bit D/A), and 4 universal digital I/O channels.
- iNET-460: Provides 28 digital I/O channels configured as 12x universal digital I/O (20 mA sink) plus 16x digital I/O (200 mA sink).
The system supports up to four iNET-240 controllers per computer. Accessories include wiring boxes (iNET-510 with screw terminals, iNET-511 with BNC connectors, iNET-512 for strain gages), optical isolators (iNET-330), wall and DIN rail mounting kits (iNET-530), and shunt resistors ranging from 33 Ω to 33 kΩ.
Key Product Differences
The iNET-400 Series is offered in starter system configurations:
- iNET-555: Starter system with USA plug, including the iNET-240 controller, iNET-430 card, iNET-510 wiring box, iNET-400 cage, and power supply.
- iNET-555-EU: Starter system configured for European plugs with identical component contents.
Differences between measurement cards are defined by channel count, input type, and output capabilities. The iNET-420 is optimized for multiplexed voltage inputs without analog outputs, while the iNET-430 provides high-resolution A/D conversion with integrated D/A outputs. The iNET-460 serves exclusively as a digital I/O expansion module.
Thermocouple measurements require an iNET-510 Wiring Box attached to the card cage; thermistor, RTD, resistance, current, and strain gage measurements (1/4 or 1/2 bridge) require external shunt resistors. The iNET-430 A/D card is required for measuring analog voltages when using conditioned signals from iNET-420 or iNET-423 cards routed via the backplane.