TX13-Smart-Temp-Tx
Thermoelement-Eingangstemperaturtransmitter mit Druckknopfn-Konfiguration
Thermocouple Input Temperature Transmitter w/ Pushbutton Config
Modelle auf Lager
TX13-Smart-Temp-Tx
Von
SGD
241.23
Modelle auf Lager
Produktübersicht
- Genauigkeit ± 5 µA
- Genauigkeit Detail (uscita mA/2000) o 5 uA (quale dei due è maggiore)
- Zulassungen BS EN 61326 ; 1998 – Apparecchiature elettriche per misurazione e controllo ALLEGATO A ; ALLEGATO F
- Kalibrierung Pulsante
- Kaltstellenkompensation ±0,05°C/°C
- Genauigkeit der Kaltstellen-Temperatur ±0,5 °C
- Durchmesser 43 mm
- Elektrischer Anschluss Terminale a vite
- Elektrischer Ausgang da 4 a 20 mA
- Höhe 21 mm
- Feuchtigkeitsbereich Da 10 a 90% di umidità relativa senza condensa
- Eingangsgenauigkeit ± 0,5 °C
- Betriebstemperatur, max. 85 °C
- Betriebstemperatur, min. -40 °C
- Ausgangsbelastung [(Vsupply-10)/20] kΩ
- Sondenlänge 0 mm
- Reaktionszeit 1 sec
- Selbstheizungseffekt 0,2 uA/V
- Sensortyp Trasmettitori
- Serien-ID TX13-Smart-Temp-Tx
- Einrichtungssteuerungen Pulsante, il LED di programma lampeggerà a scatti
- Mantelwerkstoff N/A
- Stabilität Offset: 0,1°C/°C; Escursione: 0,05°C/°C
- Anlaufzeit I out < 4 mA durante l'avvio
- Lagertemperatur, max. 90 °C
- Lagertemperatur, min. -50 °C
- Art der Stromversorgung CC
- Versorgungsspannung Da 10 a 30 Vcc
- Temperatureingangsbereich K: -200 bis 1370 °C; J: -100 bis 1200 °C; E: -100 bis 1000 °C; N: -180 bis 1300 °C; T: -100 bis 400 °C; R -10 bis 1760 °C; S: -10 bis 1760 °C
- Thermische Auswirkungen 1 uA/ °C
- Aktualisierungsrate, max. 500 ms
- Aufwärmzeit 1 min bis zur vollen Genauigkeit
- Gewicht 31 g
Supported Applications
The Omega TX13 is a smart in-head transmitter designed to connect to standard thermocouple sensors and convert temperature measurements into a linear (4 to 20) mA signal. It accepts inputs from Type K, J, E, N, T, R, and S thermocouples as well as mV signals. The device features galvanic isolation and is intended for use in industrial locations where it converts sensor output over a configured range into a standard transmission signal.
Operating Conditions & Performance
The TX13 operates within an ambient temperature range of -40 to 85°C (-40 to 185°F) and supports humidity levels from 10 to 90% RH non-condensing. Storage temperatures are rated for -50 to 90°C (-58 to 194°F). The transmitter achieves a response time of 1 second to reach 90% of the final value, with an update time of 0.5 seconds and a typical start-up time of 5 seconds from power up.
Accuracy specifications vary by sensor type as documented in the series data sheet:
- Type K: -200 to 1370 °C (-328 to 2498 °F) with ±0.5°C (0.9°F) or ±0.1% whichever is greater
- Type J: -100 to 1200 °C (-148 to 2192 °F)
- Type E: -100 to 1000 °C (-148 to 1832 °F)
- Type N: -180 to 1300 °C (-292 to 2372 °F)
- Type T: -100 to 400 °C (-148 to 752 °F)
- Types R and S: -10 to 1760 °C (14 to 3200 °F), with accuracy specified over the range 800 to 1600°C
- mV Input: -10 to 70 mV with ±0.02% of full scale accuracy
The output signal is a two-wire (4 to 20) mA sink, capable of low limits at 3.8 mA and high limits at 21.5 mA for burnout indication.
Configuration Options
The TX13 series supports configuration via a single pushbutton menu system indicated by 'M' and 'R' LEDs, allowing users to reconfigure transmitter parameters including input type and range selection from 56 preprogrammed ranges. The device includes user trim functionality for nulling out sensor error and programmable burnout with a sensor fail indicator.
Key configurable options include:
- Housing: DIN standard probe head enclosure (43 mm diameter x 21 mm height) providing protection from moisture, dust, and corrosive atmospheres. The manual notes the device conforms to EC directive BS EN 61326:1998 when installed in a termination head providing at least IP20 protection.
- Power Supply: Operates on 10 to 30 Vdc (example load resistance calculation provided for 24V supply).
- Connections: Screw terminal electrical connection with center hole sensor wire entry. Sensor input wires must be less than 3 m (10') to comply with EMC standards.
- Options and Accessories: Available options include TX-SCALED for factory setup of range, PSR series regulated power supplies (24 Vdc), and TX2-100 shielded cables.
Key Product Differences
The primary variation within the TX13 family is defined by the selected thermocouple type or mV input, which dictates the available measurement range. If a specific range is not specified at order time, the transmitter ships with a default configuration of 0 to 1000°C (32 to 1832°F) Type K upscale burnout.
Model variations are distinguished by:
- Sensor Input: Selection between Types K, J, E, N, T, R, S, or mV determines the valid temperature span and accuracy class.
- Output Configuration: The device functions as a two-wire (4 to 20) mA sink with specific low/high limits for fault indication.