Singapore 1800 622 1156 | Intl +65 6415 5353 | Welcome to our new site - found a bug? Please report it here
DP7000-series
Temperature Meter Alarm or On/Off Control & with Audible Buzzer
Models In Stock
- Bright-Red, 3-Digit LED Display
- J or K Thermocouple Inputs
- 16 A Relay Output
- Simple On/Off Control or Alarm
DP7000-series
From
SGD
261.15
Models In Stock
Product Overview
- Accuracy ± 1 %
- Alloy Material (-) Alumel
- Alloy Material (+) Chromel
- Control Type On/Off
- Display Note Three 12.7 mm (1/2") red digits, plus sign; update rate: 1, 2, 4 or 8 sec (adjustable)
- Display Size 12.7 mm (0.50 in)
- Display Type 3 Digit LED
- Enclosure Ratings IP64, NEMA Type 4X
- Form factor 2.79 in x 1.14 in
- Horsepower Rating 1 hp
- Measurement Type Temperature
- Memory Backup Non-Volatile
- Number of Inputs 1
- Operating Temperature, Max 70 °C
- Operating Temperature, Min 0 °C
- Power Consumption 4 VA
- Relay Output 16 A SPDT
- Relay Output Note 16 A SPDT @ 240 Vac
- Resolution 1°
- Samples,Max 1 Hz
- Series ID DP7000-series
- Storage Temperature, Max 80 °C
- Storage Temperature, Min -20 °C
- Supply Power Note 115 Vac, 230 Vac, 12 Vac/Vdc or 24 Vac/Vdc (depending on model)
- Temperature Measurement Range J: 0 to 999°C, K: 0 to 999°C
- Temperature Sensor Type Thermocouple
- Thermocouple Type J, K, S
- Weight 65 g
Supported Applications
The Omega DP7000 Series Temperature Digital Controller is designed for heating and cooling applications requiring temperature monitoring with alarm or on/off control output. The series features an internal audible buzzer and a bright-red 3-digit LED display suitable for industrial chillers, environmental chambers, walk-ins, freezers, heat sealers, sterilizers, coolers, display cases, warmers, meat and produce storage, floral preservation, laboratories, food service equipment, ovens, dryers, tool rooms, and burn-in rooms.
Operating Conditions & Performance
The DP7000 Series accepts Type J or K thermocouple inputs with a measurement range of 32 to 999°F (0 to 999°C). Accuracy is specified as ±1% FS, and the display resolution is 1°. The unit operates within an ambient temperature range of 32 to 158°F (0 to 70°C) and can be stored between -4 to 176°F (-20 to 80°C). Enclosure protection meets NEMA 4X (IP64) ratings. Installation warnings specify that the unit must be mounted away from vibration, impacts, water, and corrosive gases, and probe cables should not be installed near power cables.
Control & Alarm Parameters
The controller supports programmable parameters including set point (SP), hysteresis (r0: 1 to 99 Degrees), cycle time (c0: 0 to 999 Seconds), and ambient probe adjustment. The output is an SPDT relay rated at 16A @ 240 VAC resistive, configured for simple on/off control or alarm functions.
Response Time Configuration
Probe response time (P6) is configurable via parameter settings: 0=8 sec, 1=4 sec, 2=2 sec, and 3=1 sec. The unit includes error and alarm warning capabilities with password protection for the silicone front keypad.
Configuration Options
The series is available in eight distinct models (DP7001 through DP7008) configured by power supply voltage, temperature scale display, and input type. All variants support Type J or K thermocouple inputs; the manual notes that parameter P5 allows selection of tcJ, tch, or tcS.
Power Supply & Display Options
- 115 VAC: DP7001 (°F), DP7002 (°C)
- 230 VAC: DP7003 (°F), DP7004 (°C)
- 12 VAC/VDC: DP7005 (°F), DP7006 (°C)
- 24 VAC/VDC: DP7007 (°F), DP7008 (°C)
Housing & Dimensions
The unit features a front panel with overall dimensions of 75 mm width x 34 mm height and a depth of 69 mm. The required cutout for the panel is 71 x 29 mm (2.80 x 1.14"). Electrical connections are made via terminals: Probe input at terminals 1,2; Power Supply at 7,8; and Output at 9,10,11 with NC, COM, NO configurations.
Approvals & Accessories
The series carries CE and UL (cUR) certifications. An optional noise suppression kit (CNQUENCHARC) is available for 110 to 230 Vac applications.
Key Product Differences
Variants within the DP7000 Series differ primarily by power supply voltage and display unit selection. Models ending in odd numbers (DP7001, DP7003, DP7005, DP7007) are configured for Fahrenheit (°F), while even-numbered models (DP7002, DP7004, DP7006, DP7008) display Celsius (°C). The input type is listed as Type J/K across the standard model lineup in the data sheet "To Order" table. All variants share identical physical dimensions, enclosure ratings, and relay output specifications.