Singapore 1800 622 1156 | Intl +65 6415 5353 | Welcome to our new site - found a bug? Please report it here
OM-EL-USB-2-LCD-Series
Temperature, Humidity and Dew Point Data Logger with LCD Display
Models In Stock
- 0 to 100% RH Measurement Range
- -35 to 80°C (-31 to 176°F) Temperature Measurement Range
- Dew Point Indication via Windows® Control Software
- USB Interface for Set-Up and Data Download
OM-EL-USB-2-LCD-Series
From
SGD
384.32
Models In Stock
Product Overview
- Additional Features 1 High Accuracy
- Alarm Note High/low alarm thresholds for %RH and temperature selectable in software
- Battery life up to 1 yr
- Battery Size and Type 1/2 AA Li-ion
- Data Interface USB
- Dew Point Accuracy ± 1.1°C
- Display Type LCD
- Form factor Handheld
- Height 25.3 mm
- Humidity Repeatability ± 0.1%
- Input Type Internal
- Measurement Type Humidity, Temperature
- Memory 16379
- Memory Note 16,379 temperature and 16,379 relative humidity readings
- Number of Measurements 2
- Operating Temperature, Max 80 °C
- Operating Temperature, Min -35 °C
- Relative Humidity Accuracy ± 2% RH
- Relative Humidity Accuracy Note Accuracy [20 to 80% RH] (OM-EL-USB-2-LCD-PLUS); ± 2.0% RH typical; ± 4.0% RH max
- Relative Humidity, Max 1
- Relative Humidity, Min 0%
- Relative Humidity Resolution 0.005
- Samples,Max 16379
- Sampling Rate 10 Hz (10 updates/second)
- Series ID OM-EL-USB-2-LCD-Series
- Software Compatibility Windows XP/Vista/7 and 8 (32-bit and 64-bit)
- Supply Power Type Battery
- Temperature Accuracy ± 0.3 °C (± 0.54 °F)
- Temperature Accuracy Note ± 0.3°C (± 0.6°F) typical; ± 1.5°C (± 3.0°F) max
- Temperature Measurement, Max 80 °C
- Temperature Measurement, Min -35 °C
- Temperature Repeatability ± 0.1 °C
- Temperature Resolution 0.5 °C
- Weight 40 g
- Width 126 mm
Supported Applications
The OM-EL-USB-2-LCD series provides standalone measurement and storage of relative humidity, temperature, and dew point, making it suited to any workflow that needs an unattended record of environmental conditions. With measurement ranges of 0 to 100% RH and -35 to 80°C (-31 to 176°F), the loggers cover everything from sub-zero cold storage to warm, humid processing areas.
Typical deployments include:
- Cold storage, refrigeration, and warehouse monitoring where both temperature and humidity must be documented.
- HVAC commissioning and building performance surveys.
- Museum, archive, and gallery environments where humidity stability protects sensitive collections.
- Greenhouse, horticultural, and controlled-growth spaces.
- Transport and distribution studies that require a portable, self-contained record.
Because each logger carries a high-contrast LCD, technicians can read the current relative humidity, temperature, and calculated dew point directly on the unit, while user-programmable high and low alarm thresholds flag any excursion via red and green status LEDs.
Operating Conditions & Performance
The loggers operate across a range of -35 to 80°C (-31 to 176°F). At temperatures below -20°C (-4°F) the LCD display exhibits slower response times of about 10 seconds, though logging itself continues normally.
Core measurement performance is shared across the series:
- Temperature resolution of 0.5°C (1.0°F) with repeatability of ±0.1°C (±0.2°F).
- Relative humidity resolution of 0.5% RH with short-term repeatability of ±0.1% RH.
- Calculated dew point accuracy of ±1.1°C (±2°F) for relative humidity measurements between 40 to 100% RH at 25°C.
Each logger stores up to 16,379 temperature and 16,379 relative humidity readings, with the logging interval selectable in software from 10 sec to 12 hrs. Alarm thresholds and start date/time are all configured through the supplied Windows control software.
Power comes from an included ½ AA 3.6V lithium battery delivering up to 1 year of operation depending on sample rate, ambient temperature, and use of the LCD display. Each unit weighs 40 g (1.4 oz) and measures 126.0 mm (4.96 in) in length by 25.3 mm (1 in) in diameter. The series carries CE marking, is RoHS compliant, and is manufactured under ISO 9001 certification.
Configuration Options
The two logger variants share the same 0 to 100% RH and -35 to 80°C (-31 to 176°F) ranges, LCD, USB interface, and alarm features, but differ in measurement accuracy.
OM-EL-USB-2-LCD
The standard logger provides temperature accuracy of ±0.5°C (±1.0°F) with a maximum overall error of ±2.0°C (±4.0°F), and relative humidity accuracy of ±3.0% RH with a maximum of ±5.0% RH across the 20 to 80% RH band.
OM-EL-USB-2-LCD-PLUS
The high accuracy variant tightens performance to ±0.3°C (±0.6°F) for temperature, with a maximum overall error of ±1.5°C (±3.0°F), and relative humidity accuracy of ±2.0% RH with a maximum of ±4.0% RH across the 20 to 80% RH band. It is the preferred choice where closer tolerance on both temperature and humidity is required.
Both variants deliver identical dew point accuracy of ±1.1°C (±2°F) and use the same ½ AA 3.6V lithium battery and OM-EL-BATT replacement.
Key Product Differences
The series is ordered by the following model numbers:
- OM-EL-USB-2-LCD — temperature, humidity and dew point data logger with LCD display.
- OM-EL-USB-2-LCD-PLUS — high accuracy temperature, humidity and dew point data logger with LCD display.
- OM-EL-BATT — replacement 3.6V lithium battery.
Each logger ships complete with Windows control software on CD-ROM, a protective cap, and a 3.6V lithium battery.