Skip to search Skip to main content Skip to navigation

Singapore 1800 622 1156 | Intl +65 6415 5353 | Welcome to our new site - found a bug? Please report it here

We noticed you are in , please visit your local site by clicking the below link for regional offers and support.

D1411

OMEGABUS® Digital Transmitters

SGD924.17 / each

Item# D1411

Only 16 left

Limited Stock

Product Specs

<< See all Product Models
Brand
Accuracy ±0.01 % of reading ±10 µs
Analog I/O Note RTD: Input protection to 120 Vac, Automatic linearization and lead compensation, User selectable °C or °F, Resolution: 0.1°, Accuracy: ±0.3°C, Input Connections: 2, 3,or 4 wire, Excitation Current: 0.25 mA, Lead resistance effect: 3 wire –2.5°C per Ω of unbalance; 4 wire –negligible, Max Lead Resistance: 50Ω, 1 Digital Output
Baud Rate 300 to 38,400
Current Measurement Range 4 to 20 mA
Data Interface RS232C
Data Interface Note Up to 124 multidrop modules per communications port, ASCII Format command/ response protocol, Can be used with ‘dumb’ terminal, Parity options: odd, even, none, All communications setups stored in memory, Checksum can be added to any command or response, user selectable channel address
Digital Output Open collector to 30V,100 mA max load
Electrical Connection Screw Terminal
Excitation Current: 0.25 mA
Frequency Input Range 1 Hz to 20 kHz
Frequency Measurement Range N/A
GrossWeightValue 0.44
Height 6.223 mm
Input Control Signal ±100 Vdc
Input Type RTD
Lead Resistance, Max 50 Ω
Lead resistance effect 3 Wire –2.5°C /Ω of unbalance; 4 Wire – Negligible
Length 9.144 mm
Materials ABS
Number of Channels, Input Analog: 1
Number of Channels, Output Digital: 1
Operating Temperature, Max 70 °C
Operating Temperature, Min -25 °C
Output Signal Digital
Protection Input Protection: 250 Vac
Relative Humidity 0 to 95% RH non-condensing
Resolution 0.1°C
Sampling Rate 2 Hz (2 updates/second)
Sensor Type 100 Ω RTD
Series ID D1000-Series
Storage Temperature, Max 85 °C
Storage Temperature, Min -25 °C
Supply Power Type DC
Supply Voltage 10 to 30 Vdc, 0.75 W
Temperature Measurement Range RTD: -200 to 850°C
Voltage Measurement Range N/A
Width 2.794 mm
excitation Current: 0.25 mA
Country of Origin United States
See All Specs Show Less
OMEGABUS® Digital Transmitters D1411 D1411
en-SG
en_SG
Save Configuration