Skip to search Skip to main content Skip to navigation

Singapore 1800 622 1156 | Intl +65 6415 5353 | Welcome to our new site - found a bug? Please report it here

We noticed you are in , please visit your local site by clicking the below link for regional offers and support.

FMA4000-Series

Programmable Mass Flow Meter and Totalizer

Models In Stock
  • 23 Selectable Engineering Units (Including User Defined)
  • Programmable Totalizer
  • High and Low Gas Flow Alarms
  • Two Sets Programmable SPDT Relays with Latching Feature
FMA4000-Series
From SGD 1,940.03
Models In Stock
Programmable Mass Flow Meter and Totalizer FMA4000-Series FMA4000-Series
loading all models
Product Overview
  • Accuracy ± 1 %
  • Accuracy Detail ± 1% of FS at calibration temperature and pressure
  • Altitude Sensitivity Deviation of up to 1% from stated accuracy, after re-zeroing
  • Calibration NIST 10-Point Certificate
  • Data Interface RS232
  • Electrical Output 4 to 20 mA, 0 to 5 Vdc
  • Enclosure Ratings Inst. Level II/Poll. Degree II (IEC 60664)
  • Humidity Range Up to 70%
  • Leak Rate Under Vacuum less than 10^⁻9 cc He/s
  • Materials, Wetted 316 Stainless Steel, Aluminum, Brass, FKM
  • Operating Pressure, Max 500 psi
  • Operating Pressure, Min 0 psi
  • Operating Temperature, Max 50 °C
  • Operating Temperature, Min 5 °C
  • Output Detail Linear 0 to 5 Vdc (3000 Ω min load impedance); Linear 4 to 20 mA (500 Ω max loop resistance). Max noise 20 mV peak to peak (for 0 to 5 Vdc output)
  • Output Signal Current, Voltage
  • Power Consumption 2.4 W
  • Pressure Coefficient 0.01% FS/psi
  • Process Connection Type Compression Fitting
  • Repeatability ± 0.15%
  • Response Time 2 sec
  • Response Time Note 600 ms time constant; approximately 2 seconds to within ± 2% of set flow rate for 25 to 100% of full scale flow
  • Series ID FMA4000-Series
  • Supply Power Note Transducer Input Power: 11 to 26 Vdc, 100 mV max peak to peak output noise
  • Supply Voltage 11 to 26 Vdc
  • Switch Rating 30 Vdc, 1A
  • Switch Type SPDT NO/NC, Selectable
  • Temperature Coefficient 0.15% FS/°C
  • Turndown Ratio 50:1
  • Volumetric Flow Rate, Min 0.1 SCCM

Supported Applications

The Omega FMA4000 Series comprises programmable gas mass flow meters and totalizers designed for the precise measurement of clean gases. The series supports internal conversion factors for up to 32 specific gases, including Air (AIR), Nitrogen (N2), Oxygen (O2), Argon (AR), Helium (HE), Hydrogen (H2), Carbon Dioxide (CO2), and Natural Gas (NG). These instruments are intended for applications requiring digital flow monitoring with configurable engineering units. The product overview explicitly states that the FMA 4000 Mass Flow Meter will not operate with liquids; only clean gases are allowed to be introduced into the instrument.

Operating Conditions & Performance

The series operates within a gas and ambient temperature range of 5 to 50°C (41 to 122°F). Flow accuracy is specified as ±1% of full scale at calibration temperature and pressure, with repeatability of ±0.15% of full scale. The flow response time features a 600 ms time constant, reaching approximately 2 seconds to within ±2% of the set flow rate for flows between 25 to 100% of full scale.

Maximum gas pressure is rated at 3447 kPa gauge (500 psi). Maximum allowable pressure drop varies by range: for maximum flow ≤10 SLM, the limit is 1.28 kPa (0.18 psi); for maximum flow >10 SLM, the limit is 27.58 kPa (4 psi). The instruments are rated for relative gas humidity up to 70% and maintain leak integrity of 1 x 10⁻⁸ SCCS He max to the outside environment.

Measurement Ranges

The series covers a broad envelope from low flow rates to high volume, with specific ranges including:

  • Low Flow: 0 to 5 SCCM through 0 to 1 SLM (Standard Liters per Minute)
  • Mid Range: 0 to 2 SLM through 0 to 60 SLM
  • High Volume: 0 to 80 SLM and 0 to 100 SLM

A turndown ratio of 50:1 is supported across the series.

Configuration Options

The FMA4000 Series offers extensive configuration options for output signals, communication protocols, and physical construction to meet specific integration needs.

Outputs and Communication

  • Analog Outputs: Linear 0 to 5 Vdc (minimum load impedance 3000 Ω) or linear 4 to 20 mA (maximum loop resistance 500 Ω). Max noise is specified as 20 mV peak to peak for the 0 to 5 Vdc output.
  • Relay Outputs: Two sets of programmable SPDT relays with latching, rated at 30 Vdc and 1A. These support high and low gas flow alarms.
  • Digital Interface: Standard RS232 digital interface is available; units can be configured for RS485 by adding the "-RS485" suffix to the model number at no additional cost.

Housing and Wetted Materials

  • Standard Body: Anodized aluminum with brass, 316 stainless steel components, and FKM O-rings. Optional stainless steel bodies are available by adding the "-ST" suffix.
  • O-ring Options: Standard FKM; optional Buna, EPR (Ethylene Propylene), or perfluoroelastomer materials.

Process Connections and Dimensions

Inlet and outlet connections utilize compression fittings. The standard configuration for most models is 6.35 mm (¼"). For units with ranges of 60 SLM and larger, the connection size increases to 9.53 mm (⅜"). Optional configurations include 3.18 mm (⅛") or 9.53 mm (⅜") compression fittings.

Physical dimensions vary by flow range:

  • 5 mL-10 LPM Range: Overall length A: 3.09 in (78.6 mm); Width B: 5.11 in (129.7 mm).
  • 20-50 LPM Range: Overall length A: 4.13 in (104.8 mm); Width B: 6.14 in (156.0 mm).
  • 60-100 LPM Range: Overall length A: 4.13 in (104.8 mm); Width B: 6.25 in (158.8 mm).

Key Product Differences

The series is divided into two primary model families distinguished by the presence of a local display:

  • FMA-4100 Series: Models without an integral display (e.g., FMA-4102 through FMA-4119). These units provide analog and digital outputs but rely on external monitoring or the RS232 interface for data readout.
  • FMA-4300 Series: Models with an integral display (e.g., FMA-4302 through FMA-4319). These feature a local 2-line x 16-character LCD with adjustable backlighting, allowing for direct viewing of flow readings and totalizer values.

All models support automatic sensor zero offset adjustment, which can be activated locally via the maintenance push button (on display models) or remotely via the digital interface. Calibration is performed at standard conditions [101.4 kPa (14.7 psia) and 21.1°C (70°F)] unless otherwise requested.

Accessories

accessories

15-PIN D 6' TO PC 3' TO PS
SGD154.79 / each
0 In Stock

meters/controllers

PS 240VAC AUSTRALIAN PLUG
SGD253.84 / each
0 In Stock
PS 240 VAC AUST PLUG ANALOG WR
SGD355.70 / each
0 In Stock
PS 230VAC EUROPEAN PLUG
SGD205.26 / each
0 In Stock
PS 230VAC EU PLG W/ANALOG WRS
SGD296.61 / each
0 In Stock
PS 110VAC US PLUG
SGD185.15 / each
0 In Stock
PS 240VAC U.K. PLUG
SGD243.50 / each
0 In Stock
PS 240VAC US PLG W/ANALOG WRS
SGD355.92 / each
0 In Stock
en-SG
en_SG
Save Configuration