Skip to search Skip to main content Skip to navigation

Taiwan 0809 090 375 | Intl +65 6415 5353 | Welcome to our new site - found a bug? Please report it here

We noticed you are in , please visit your local site by clicking the below link for regional offers and support.

FMAA2000-Series

Mass Controllers With Or Without Integral Display

  • ± 1% Accuracy
  • Linear Output
  • Low Cost
  • Thermal Technology
FMAA2000-Series
From TWD 32,496
Mass Controllers With Or Without Integral Display FMAA2000-Series FMAA2000-Series
loading all models
Product Overview
  • Accuracy ± 1 %
  • Accuracy Detail ± 1% of full scale including linearity
  • Additional Features 1 Power Supply Included
  • Calibration NIST 5-Point Certificate
  • Electrical Connection Sub-D Male Miniature Connector
  • Electrical Output 4 to 20 mA, 0 to 5 Vdc
  • Height 6.05 in
  • Leak Rate Under Vacuum less than 10^⁻⁶ cc He/s
  • Length 3.8 in
  • Media Compatibility Clean dry air / inert gas, HVAC / room air, Inert / non-reactive gases, Oxygen
  • Operating Pressure, Min 0 psi
  • Operating Temperature, Max 50 °C
  • Operating Temperature, Min 0 °C
  • Output Detail Linear 0 to 5 Vdc, 1000 Ω min load, 4 to 20 mA, 500 Ω loop resistance
  • Output Signal Current, Voltage
  • Pressure Coefficient 0.01% FS/psi
  • Process Connection Size 1/4 in
  • Repeatability ± 0.15%
  • Required Pressure, Min 1 psi
  • Response Time 5 sec
  • Series ID FMAA2000-Series
  • Supply Power Note 24 Vdc @ 150 mA, 115 Vac, 220 Vac with AC adaptor
  • Temperature Coefficient 0.05% FS/°C
  • Turndown Ratio 100:1
  • Volumetric Flow Rate, Min 0.01 SCCM
  • Weight 2.75 lb
  • Width 1.5 in
The FMA-A2100/2200/2300/2400 Series Electronic Mass Flow meters/ Controllers provide high performance, versatility and state-of-the-art design in one compact package. The FMA-A2100/ 2200/2300/2400 uses capillary-type thermal technology to directly measure mass flow of gases. No temperature, pressure, or square root corrections are required. The FMA-A2300/2400 Series comes with an LCD display, and all models come with linear 0-5 and 4-20 mA output.
The FMA-A2100/2200/2300/2400 measures the mass flow rate of gases in 24 ranges from 0-10 SCCM to 0-100 SLM. For the complete listing, refer to the range table below. The FMA-A2100/2200/ 2300/2400 Series is compatible with most noncorrosive gases. The user is advised to check the wetted materials against gas compatibility.
OMEGA’s Mass Flow Controllers use an internal electromagnetic proportional valve to control the mass flow rate. A command signal can be supplied either by the internal setpoint pot or by a 0-5 Vdc external source.