Magnehelic® Transmitter for Low DP Monitoring in HVAC, 4-20 mA Output

  • Easy to read gage permits viewing from far away
  • Patented design provides quick response to pressure changes means no delay in signaling and alerting to critical situations
  • Durable and rugged housing and high-quality components combined provides long-service life and minimized down-time
  • Optional stainless steel bezel is the same installation diameter as Magnehelic® gage and simplifies field upgrade to 605 indicating transmitter
Series-605
From SGD 845.53
Magnehelic® Transmitter for Low DP Monitoring in HVAC, 4-20 mA Output Series-605 Series-605
loading all models
Product Overview
  • Accuracy Detail Electrical: ± 4%, Mechanical: ± 4% (includes linearity, hysteresis, repeatability)
  • Compensated Temperature, Max 48.9 °C
  • Compensated Temperature, Min 0 °C
  • Dial Depth 68 mm
  • Dial Dia 4 in
  • Dial Outer Diameter 127 mm
  • Display Type N/A
  • Electrical Connection Screw Terminal
  • Electrical Output 4 to 20 mA
  • Long Term Stability ± 1% FS/year
  • Loop Resistance 0 to 1250 Ω max
  • Materials, Wetted Consult Factory
  • Media Compatibility Clean dry air / inert gas, HVAC / room air, Inert / non-reactive gases, Helium, Nitrogen, Non-Conductive Gases, Non-Corrosive Dry Gases
  • Mounting Note Vertical Diaphragm
  • Operating Temperature, Max 48.9 °C
  • Operating Temperature, Min -6.67 °C
  • Output Signal Current
  • Power Consumption max 38 mA
  • Measurement Pressure Type Differential
  • Process Connection Size 1/8 in
  • Process Connection Type NPT Female
  • Proof Pressure Up to 10 psi
  • Series ID Series-605
  • Span Adjustment Potentiometers
  • Supply Power Type DC
  • Supply Voltage 10 to 35 Vdc
  • Thermal Effects ± 0.045% FS/°C
  • Weight 811 g
  • Zero Setting Adjustable Range Protected Potentiometers

Supported Applications

The Dwyer Series 605 Magnehelic® Differential Pressure Indicating Transmitter is designed for low differential pressure monitoring in building HVAC systems. It provides simultaneous local indication on an analog scale and a standard two-wire, 4-20 mA signal suitable for control applications where visual verification during routine maintenance or troubleshooting is required. The unit measures positive, negative, or differential air and non-combustible, compatible gases.

Operating Conditions & Performance

The Series 605 operates within an ambient temperature range of 20 to 120°F (-6.67 to 48.9°C), with a compensated temperature range of 32 to 120°F (0 to 48.9°C). The thermal effect is specified as ±0.025% FS/°F (0.045% FS/°C). Measurement ranges span from 0-0.5 in w.c. up to 0-50 in w.c., with additional models covering bidirectional spans such as 60-0-60 Pa and 100-0-100 Pa, alongside single-ended Pascal ranges including 0-60 Pa through 0-500 Pa.

Electrical accuracy varies by model range: ±4% of full scale for the lowest differential spans (e.g., 0.05-0.20 in w.c.), improving to ±0.5% of full scale for ranges from 0-2.0 in w.c. through 0-30 in w.c. and specific Pascal models. Mechanical accuracy is listed separately per model, ranging from ±2% to ±4%. The device features a patented design providing quick response to pressure changes.

Configuration Options

The series supports multiple configuration options for mounting, bezel material, and calibration documentation:

  • Housing & Bezel: Standard durable housing with an optional 304 brushed stainless steel bezel (-SS), which is backward compatible with standard Magnehelic® gage installation diameters.
  • Mounting Accessories: Includes options for flush mounting (A-298 flat aluminum bracket) and surface mounting via a steel bracket with gray hammertone epoxy finish (A-370).
  • Calibration Documentation: A NIST traceable calibration certificate is available as an option (-NIST).
  • Process Connections & Electricals: Features 1/8" female NPT process connections and a screw terminal block for electrical wiring. The unit requires a 10-35 VDC power supply (two-wire) with a maximum loop resistance of 0 to 1250 Ω.
  • Adjustments: Zero and span adjustments are provided via protected potentiometers.

The unit weighs 1 lb, 12.6 oz (811 g). Wetted materials must be confirmed by consulting the factory. The device is not field repairable; units requiring service should be returned to the manufacturer.

Key Product Differences

Variants within the Series 605 are distinguished primarily by their measurement range and corresponding accuracy specifications as defined in the model chart:

  • Inches of Water Column (in w.c.):** Models include 605-00N (0.05-0.20), 605-11 (±0.25), and standard ranges from 605-0 through 605-30, with maximum pressure limits varying between 2 psi (13.79 kPa) and 11 psi (75.8 kPa) depending on the specific range.
  • Pascal Ranges: Models such as 605-60PA through 605-500PA cover ranges from 0 to 60 Pa up to 0 to 500 Pa, with maximum pressure limits typically at 10 psi (68.95 kPa) or 2 psi (13.79 kPa).
  • Bidirectional Models: Specific models like 605-12 and 605-13 offer bidirectional measurement capabilities (e.g., ±60 in w.c.).

Accessories

accessories

A-277 PRECISION RESISTOR
SGD23.75 / each
0 In Stock
4" 303 SS straight static pressure tip with flange, 1/4" hose barb.
SGD17.87 / each
0 In Stock

consumables

A-135 SILICONE GASKET
SGD10.35 / each
0 In Stock

installation hardware

Flat aluminum bracket for flush mounting (for Series A3000 Photohelic®, Series 4000 Capsuhelic®, Series 605, and Series 3000MR)