Singapore 1800 622 1156 | Intl +65 6415 5353 | Welcome to our new site - found a bug? Please report it here
Series-IS626
IS626 Intrinsically Safe Pressure Transmitter, 0.25% Accuracy, NEMA 4X
- Exceptional accuracy for ensuring tight-control and minimizing costly out of specification conditions
- NEMA 4X rated enclosure provides protection in harsh environments permitting outdoor monitoring or in areas where dust and particulate matter exists
- Robust sensor provides shock and vibration resistance insuring stability in controlling pressure for process applications
Series-IS626
From
SGD
945.76
Product Overview
- Accuracy ± 0.25 %
- Accuracy Detail 0.25% FS
- Applications Chemical Refineries, Fluid Measurement and Control, Industrial and Manufacturing
- Burst Pressure 150 psi Maximum
- Compensated Temperature, Max 176 °F
- Compensated Temperature, Min 0 °F
- Electrical Connection Cable
- Electrical Output 4 to 20 mA
- Enclosure Ratings IP66, NEMA Type 4X
- Loop Resistance 0 to 900 Ω max
- Materials, Wetted 316 Stainless Steel, 316L Stainless Steel
- Media Compatibility Clean dry air / inert gas, Clean process / cooling water, Compatible Liquids, Inert / non-reactive gases, Oils / lubricants, Organic solvents, Water
- Mounting Orientation Not Position Sensitive
- Operating Temperature, Max 176 °F
- Operating Temperature, Min 0 °F
- Output Detail 4 to 20 mA
- Output Signal Current
- Power Consumption 38 mA
- Measurement Pressure Type Gauge
- Process Connection Size 1/4 in
- Process Connection Type NPT Male
- Proof Pressure Up to 30 psi
- Response Time 50 ms
- Series ID Series-IS626
- Supply Power Type DC
- Supply Voltage 10 to 28 Vdc
- Thermal Effects ± 0.02% FS/°F (includes zero and span)
- Weight 252 g
Supported Applications
The Dwyer Series IS626 Intrinsically Safe Pressure Transmitter converts pressure into a standard 4-20 mA output signal for use in hazardous (classified) locations. Designed to measure compatible gases and liquids, the series is UL listed for intrinsic safety ('ia') and suitable for industrial environments requiring protection against ignition sources.
Documented approval classifications include:
- Class I Div. 1 Groups A,B,C,D
- Class II Div. 1 Groups E,F,G
- Class III Div. 1
- Class I Zone 0 AEx ia IIC T4 Ga
- Zone 20 AEx ia IIIC T135°C Da
- Ex ia IIC T4 Ga and Ex ia IIIC T135°C Da (Ta = -20°C to 80°C)
Operating Conditions & Performance
The Series IS626 delivers a full-scale accuracy of 0.25% FS, which includes linearity, hysteresis, and repeatability. The compensated temperature range is -4 to 176°F (-20 to 80°C) per the instruction manual or 0 to 176°F (-18 to 80°C) as noted in the datasheet specifications; thermal effect is ±0.02% FS/°F (includes zero and span). The device operates on a power supply of 10-28 VDC with a maximum current consumption of 38 mA.
Performance limits include:
- Response Time: 50 msec
- Loop Resistance: 0-900 Ω max
- Pressure Limits: See Pressure Range Table (ranges available from 0 to 15 psia up to 0 to 8000 psig)
- Mounting Orientation: Mount in any position
Configuration Options
The series supports a broad envelope of configurations for process connections, electrical interfaces, and housing styles. Wetted materials are Type 316 or 316L SS.
- Process Connections: Available with 1/4" male NPT, female NPT, BSPT male ISO 228 R 1/4", or BSPT female ISO 228 RC 1/4" fittings. The housing features a 1-1/16 [26.99] HEX dimension.
- Electrical Connections: Options include a 3 ft cable, extended cables (up to 9'), or a 4-pin M-12 connector. Accessories such as the A-295 Female M-12 Connector and A-231 Shielded Cable are available for specific wiring needs.
- Housing: NEMA 4X (IP66) enclosure rated for harsh environments; general purpose housing style (-GH).
- Output Signal: 4-20 mA, 2-wire loop powered output.
Key Product Differences
The Series IS626 is configured via a model number guide following the pattern: IS626 - <RANGE> - <HOUSING> - <FITTINGS> - <CABLES AND CONNECTORS> - <ELECTRICAL OUTPUT> - <OPTIONS>.
Key variations include:
- Ranges (-00 to -26): Span from 0 to 15 psia through 0 to 8000 psig, covering both absolute and gauge pressure applications.
- Fittings (P1-P4): Selection between male/female NPT or BSPT threads determines the process interface geometry.
- Cables/Connectors (-E1 to -E6): Choices range from standard 3' cable lengths to Bendex connections, affecting installation flexibility and loop resistance calculations.
- Options: An aluminum tag (Suffix 'AT') or NIST traceable calibration certificate can be added. Note that units with the aluminum tag option require removal of the tag prior to installation.
PDFs & Manuals