Singapore 1800 622 1156 | Intl +65 6415 5353 | Welcome to our new site - found a bug? Please report it here
Series-PFG2
Inline Filter Differential Pressure Gauge - 1/8" NPT, Clean/Dirty Zones
- Simple easy to understand indicator means no guessing filter status
- Removable mounting block provides direct mounting options especially in difficult filter access locations
- Quick installation reduces time to operation
Series-PFG2
From
SGD
184.49
Product Overview
- Applications Filter Monitoring
- Dual false
- Materials Glass Filled Polyamide, Polyester, Aluminum, Fluoroelastomer
- Materials, Wetted Aluminum, Fluoroelastomer, Glass-filled Nylon, Stainless Steel
- Media Compatibility Clean dry air / inert gas, Clean process / cooling water, Corrosive chemicals / acids / bases, Fuel gases, HVAC / room air, Hydraulic fluids, Inert / non-reactive gases, Liquids, Oils / lubricants, Organic solvents, Steam, Non-Corrosive Dry Gases, Oil, Oxygen, Solvents, Water, Water-based fluids
- Mounting Orientation Not Position Sensitive
- Operating Temperature, Max 200 °F
- Operating Temperature, Min 0 °F
- Pressure Limits Up to 300 psi
- Measurement Pressure, Min 0 psi
- Measurement Pressure Type Differential
- Process Connection Size 1/8 in
- Process Connection Type NPT Female
- Series ID Series-PFG2
- Weight 272.2 g
Supported Applications
The Dwyer Series PFG2 Process Filter Gage is designed for determining the state of an in-line filter. The differential pressure indicator determines the pressure drop on either side of a filter through its 1/8" female NPT pressure connections and relates the value to one of three zones: clean (green), change (yellow), or dirty (red). The series is suited for filter applications, line loss, valve drop, and many other differential pressure applications where a simple indicator is needed.
Operating Conditions & Performance
The Series PFG2 operates with liquids and gases compatible with stainless steel (SS), glass filled nylon (GFN), and fluoropolymer. The maximum process temperature limit is 200°F (93°C) and the pressure rating is 300 psig (20.7 bar). Accuracy is specified as ±5% FS.
Configuration Options
The series offers three distinct measurement ranges, each with defined color-coded zones for filter status indication:
- PFG2-02 (Range 0 to 5 psid): Green zone: 0 to 2.5 psid; Yellow zone: 2.5 to 3.75 psid; Red zone: 3.75 to 5 psid.
- PFG2-03 (Range 0 to 10 psid): Green zone: 0 to 5 psid; Yellow zone: 5 to 7.5 psid; Red zone: 7.5 to 10 psid.
- PFG2-06 (Range 0 to 25 psid): Green zone: 0 to 11 psid; Yellow zone: 11 to 18.5 psid; Red zone: 18.5 to 25 psid.
The dial indicates the direction of process flow with an arrow pointing to the low pressure port. The unit features a glass filled nylon body, aluminum mounting block, polyester lens, and fluoroelastomer elastomers. Wetted materials include Aluminum, SS, glass filled nylon, and fluoropolymer.
Key Product Differences
The primary variation across the Series PFG2 is the differential pressure range selected via the model suffix (-02, -03, or -06). All variants share identical physical dimensions of 3.25" H x 3" W x 2.31" D (per manual) and a weight of 9.6 oz (272.2 g). Mounting is supported in any orientation using #10-32 UNF threaded holes spaced 3/4" apart.
PDFs & Manuals
Accessories
Static Pressure Sensors for Manometers & Gages across Air Filters
From SGD10.49
0 In Stock
Industrial Control: Pressure Gauges, Flow Meters & Temp Controllers
From SGD9.01
0 In Stock
Gage Guard for Pressure/Vacuum, Polypropylene, Inorganic Compatibility
From SGD194.80
0 In Stock