Skip to search Skip to main content Skip to navigation

Singapore 1800 622 1156 | Intl +65 6415 5353 | Welcome to our new site - found a bug? Please report it here

We noticed you are in , please visit your local site by clicking the below link for regional offers and support.

FL500-Series

In-line Flow Meters for Use with Water and Air

  • Direct Reading in GPM, LPM, SCFM, and SLPM
  • Scales for Air and Water
  • Fluid is Always in View
  • Mount in Any Position
FL500-Series
From SGD 510.97
In-line Flow Meters for Use with Water and Air FL500-Series FL500-Series
loading all models
Product Overview
  • Accuracy ± 5 %
  • Length 7 in
  • Materials PVC
  • Materials, Wetted 316 Stainless Steel, Brass, FKM, PVC
  • Media Compatibility Clean process / cooling water, HVAC / room air
  • Number of Tubes 1
  • Operating Pressure, Max 200 psi
  • Operating Pressure Note Max Gas Operating Pressure: 100 psi, Max Liquid Operating Pressure: 200 psi
  • Pressure Drop, Max 4 psi
  • Process Temperature, Max 66 °C
  • Scale Direct Read
  • Scale Media Calibration N/A
  • Series ID FL500-Series

Supported Applications

The FL-500 Series are in-line flowmeters for use with water and air. Fluid moves a piston against spring pressure within a transparent flow tube, and the piston position — visible through the tube — indicates flow rate directly on a printed scale, so no external metering electronics are required for a local reading.

With a PVC flow tube and float, 316 SS end fittings, brass components, and FKM seals, the meters suit water distribution, cooling-loop balancing, and compressed-air monitoring. They can be fitted with electric proximity switches (ordered separately) for flow signaling, come complete with an operator's manual, and offer a 1 YEAR WARRANTY with optional NIST (water only) and RoHS.

Do not apply wrenches on the plastic body alone when connecting or breaking pipe connections, and do not use solvent of any kind for cleaning.

Operating Conditions & Performance

Accuracy is ±5% FS with a pressure drop of 4 psig FS. Rated service is 200 psig for liquid and 100 psig for gas, both at 21°C (70°F). The maximum temperature is 66°C (150°F) at 25 psig.

Each meter is 177.8 mm (7") long. Models FL-505 through FL-515 use a 50.8 mm (2") diameter body with a 1 FNPT connection, while models FL-530 through FL-550 use a 76.2 mm (3") diameter body with a 1½ FNPT connection. A polysulfone body and float are available by adding the suffix "-PLSF" to the model number.

Configuration Options

The six base models differ in flow capacity and port size, and each is available with standard female NPT fittings or in a BSPT-threaded version (the "-BSPT" variant). All share the same PVC/316 SS construction, ±5% FS accuracy, and pressure ratings.

  • FL-505 — 1 FNPT, water 2 to 20 LPM, air 5 to 50 SCFM.
  • FL-510 — 1 FNPT, water 4 to 38 LPM, air 15 to 90 SCFM.
  • FL-515 — 1 FNPT, water 6 to 55 LPM, air 15 to 135 SCFM.
  • FL-530 — 1½ FNPT, water 11 to 110 LPM, air 30 to 300 SCFM.
  • FL-540 — 1½ FNPT, water 15 to 150 LPM, air 40 to 400 SCFM.
  • FL-550 — 1½ FNPT, water 20 to 200 LPM, air 50 to 500 SCFM.

The smaller-bore FL-505/FL-510/FL-515 group covers low-to-medium flows on a 2" body, while the larger FL-530/FL-540/FL-550 group extends to higher flows on a 3" body.

Key Product Differences

  • FL-505 and FL-505-BSPT — 2 to 20 LPM water range.
  • FL-510 and FL-510-BSPT — 4 to 38 LPM water range.
  • FL-515 and FL-515-BSPT — 6 to 55 LPM water range.
  • FL-530 and FL-530-BSPT — 11 to 110 LPM water range.
  • FL-540 and FL-540-BSPT — 15 to 150 LPM water range.
  • FL-550 and FL-550-BSPT — 20 to 200 LPM water range.

Within each pair, the base model uses female NPT end fittings and the "-BSPT" model provides BSPT threads; both are otherwise identical in flow range and construction.