ISD-TH-Series

Environmental Monitoring and Recording over the Internet

  • Virtual Chart Recorder
  • Web Server
  • Alarms by Email or Text Message
  • No Special Software Required


The ISD-TH Series recently received a hardware upgrade. If there's an issue with the probe during use, please refer to the link at the bottom of the page under 'Software and Drivers' to download the firmware update.

While this item has an extended lead time, our ISERVER2-PROBE series offer similar specs and shorter wait times.
ISD-TH-Series
From SGD 1,734.93
Environmental Monitoring and Recording over the Internet ISD-TH-Series ISD-TH-Series
loading all models
Product Overview
  • AC Adaptor Operating Temperature 0 to 40 °C
  • Accuracy Detail Accuracy/Range at 25°C: Non-Condensing: 10 to 90%: 2.75% RH, 5 to 10% and 90 to 95%: ± 3%, 0 to 5% and 95 to 100%: ± 4%
  • Alarm Alarm I/Os: Two contact inputs, TTL 0.5 mA with 10K pull-up; one open collector output 150 mA @ 30 Vdc
  • Approvals CE, FCC-B
  • Battery Operating Temperature -18 to 55 °C
  • Battery Size and Type Alkaline 9V
  • Cable Temperature, Max 125 °C
  • Cable Temperature, Min -40 °C
  • Configuration Internal Web UI
  • Data Interface Ethernet
  • Data Interface Note Ethernet : (RJ45) Fixed or auto negotiating 10/100BASE-T, AUTO MDI/MDIX Protocols: TCP, UDP, SNMP, SMTP, NTP, ARP, ICMP, DHCP, DNS, HTTP, and Telnet
  • Display LCD
  • Display Note 32 digits 4.8 x 9.7 mm (0.19 x 0.38")
  • Form factor Wall mount bracket
  • Height 1.31 in
  • Hysteresis ± 1% RH
  • Input Type External
  • Length 4.69 in
  • Logging Modes Fixed interval
  • Measurement Type Relative Humidity, Temperature
  • Memory 2 GB SD Flash Card
  • Memory Note 8 months of data storage at 1 second recording intervals or 7 years at 10 sec intervals
  • Non-Linearity ± 3%
  • Number of Measurements 2
  • Number of Relays 2
  • Operating Temperature, Max 60 °C
  • Operating Temperature, Min 0 °C
  • Relative Humidity Accuracy ± 2.75% for 10 to 90%; ± 3% for 5 to 10% and 90 to 95%; ± 4% for 0 to 5% and 95 to 100%
  • Relay Output 1.5 A @ 30 Vdc
  • Repeatability ± 0.1%
  • Response Time Temperature: 5 to 30 sec, RH: 8 sec
  • Response Time Note Temperature: 5 to 30 seconds, tau 63%, RH: 8 seconds, tau 63%
  • RH Measurement Range 0 to 100% RH
  • RH Resolution 0.1%, 12 bit
  • Samples,Max 85k Samples, Interval 1 sec, 1 Second recording intervals or 7 years at 10 sec intervals
  • Sensor Type Probe
  • Series ID ISD-TH-Series
  • Storage Temperature, Max 85 °C
  • Storage Temperature, Min -40 °C
  • Supply Current 0.5 A
  • Supply Power Note AC Power Adaptor (Included):, Nominal Output: 9 Vdc @ 0.5 A , Back-Up Battery: 9 Vdc, Alkaline (included)
  • Supply Power Type DC/Battery
  • Supply Voltage 9 to 12 Vdc
  • Temperature Repeatability ± 0.1 °C
  • Temperature Resolution 0.1 °C
  • Weight 1.08 lb
  • Width 6.13 in

Supported Applications

The Omega iSD-TH Series is an environmental monitoring and recording device designed for remote surveillance of temperature, relative humidity, and dew point over the Internet or Ethernet. The series supports applications including clean rooms, computer server rooms, HVAC systems, pharmaceutical and food processing facilities, hospitals, laboratories, semiconductor fabs, electronic assembly areas, warehousing, museums, manufacturing environments, greenhouses, and farm animal shelters.

Operating Conditions & Performance

The iSD-TH Series operates within an ambient temperature range of 0 to 60°C (32 to 140°F) for the unit. The measurement ranges cover -40 to 125°C (-40 to 257°F) for process temperature and 0 to 100% RH for relative humidity, with an optional narrow range of 20 to 30°C available.

Accuracy specifications vary by sensor type and operating band:

  • Wand Probe Temperature Accuracy: ±0.5°C (±1°F) for 5 to 45°C (41 to 113°F); up to ±1°C (up to ±2°F) for 0 to 5°C and 45 to 60°C (32 to 41°F and 113 to 140°F).
  • Industrial Probe Temperature Accuracy: ±0.5°C (±1°F) for 5 to 45°C (41 to 113°F); up to ±1.5°C (up to ±2.7°F) for -40 to 5°C and 45 to 124°C (-40 to 41°F and 113 to 255°F).
  • Relative Humidity Accuracy: ±2.75% for 10 to 90%; ±3% for 5 to 10% and 90 to 95%; ±4% for 0 to 5% and 95 to 100%.

Resolution is specified as 0.1°C (12 bit) for temperature and 0.1%, 12 bit for humidity. Repeatability is listed at ±0.1°C and ±0.1%. Response time ranges from 5 to 30 seconds, tau 63%.

Configuration Options

The series offers configurable probe types, cable lengths, and alarm outputs tailored for specific installation needs. The unit features a built-in web server supporting protocols including TCP, UDP, SNMP, SMTP, NTP, ARP, ICMP, DHCP, DNS, HTTP, and Telnet.

Probes and Sensors

  • Standard Probe: Right angle probe with Ø13 mm (0.5 in) diameter and 83.8 mm (3.3 in) insertion length; includes a 1.8 m (6') extension cable.
  • Industrial Probe: 137 mm (5") industrial probe with Ø16 x 137 mm L dimensions, SS 316 housing material, and a 3 m (10') cable.

Data Logging and Communication

  • Storage: Includes a removable 2 GB SD Flash Memory card capable of storing up to seven years of data at ten-second intervals or eight months at one-second intervals. Data is recorded in ".txt" format.
  • Alerts: Supports email alerts, text message alerts (SMS), and SNMP traps for temperature alarms, humidity alarms, system failure, and SD card errors.

I/O and Power

  • Relay Outputs: Two 1.5 Amp output relays @ 30 Vdc controlled by alarm conditions.
  • Digital I/O: Two contact inputs (TTL 0.5 mA with 10K pull-up) and one open collector output (150 mA @ 30 Vdc).
  • Power Supply: Operates on 9 to 12 Vdc; includes a 100-240 Vac, 50/60Hz AC power adaptor with nominal 9 Vdc output. A backup 9 Vdc alkaline battery provides up to two days of operation during AC failure.

Key Product Differences

The series is available in distinct configurations based on probe type and calibration requirements:

  • iSD-TH: Standard configuration with a right angle probe and 1.8 m (6') extension cable.
  • iSD-TH-5: Configuration featuring the industrial 137 mm (5") probe with a 3 m (10') cable.

Replacement probes are offered as separate accessories, including standard right angle probes (iSDTHP) and industrial probes (iSDTHP-5). Probe caps include porous polyethylene options for wet environments (right angle: iP-PCW-10P; industrial: iP-PCI-10P) and a porous stainless steel cap with 5 μm porosity for dusty or pressurized (<35 psi) environments (iP-SC).

Calibration options include NIST traceable certificates covering three humidity points (25%, 50%, 75%) at one temperature point (25°C), available as a standalone certificate (CAL-3-HU) or bundled with replacement probes. A calibration kit containing 33% and 75% RH standards is also listed.

Accessories

accessories

CAL KIT FOR CT485B NACE
SGD413.40 / each
0 In Stock
KIT>CAP,IND PROBE,10PACK
SGD74.42 / each
8 In Stock

installation hardware

MOUNTING KIT,IND.PROBE
SGD35.12 / each
0 In Stock
en-SG
en_SG
Save Configuration