Singapore 1800 622 1156 | Intl +65 6415 5353 | Welcome to our new site - found a bug? Please report it here
ICIN-DUAL
Dual Element Thermocouple Probes with Standard Size Connectors
Models In Stock
- Two Sensor Readings Allows Two Readings of a Single Point
- Continuous Monitor and Control & Built-in Backup
- Made from Special Limits of Error Material
- Glass Filled Nylon Connector Rated to 180°C (356°F)
ICIN-DUAL
From
SGD
234.74
Models In Stock
Can't find the right model?
Use our custom configurator to fine tune your product
Product Overview
- Cable Clamp PCLM-DTC
- Connector Temperature, Max 220 °C
- Connector Temperature, Min 0 °C
- Process Connection Size N/A
- Process Temperature, Min 0 °C
- RTD Type N/A
- Series ID ICIN-DUAL
- Temperature Sensor Type Thermocouple
Supported Applications
The Omega ICIN-DUAL series consists of Dual Element Thermocouple Assemblies with Standard Size Connectors. These assemblies are manufactured using 4-conductor OMEGACLAD™ wire and feature rugged DTC connector terminations. Documented applications include two sensor readings with built-in backup, two readings of a single point, and continuous monitor and control.
Operating Conditions & Performance
The series meets or exceeds Special Limits of Error (SLE) and EN 60584-2, Tolerance Class 1. The glass-filled nylon connector body is rated to 220°C (425°F). Standard overall length for the probes is 300 mm (12"). Sheath diameters range from 1.5 to 6.0 mm (1/16" to 1/4").
Configuration Options
The ICIN-DUAL series supports a broad configuration envelope across thermocouple alloys, sheath materials, junction types, and special service options.
- Thermocouple Alloys: IRON-CONSTANTAN (Type J), CHROMEGA™-ALOMEGA™ (Type K), CHROMEGA CONSTANTAN (Type E), and COPPER-CONSTANTAN (Type T).
- Sheath Materials: 304 SS, Inconel®, or Super OMEGACLAD™ XL Sheath. To order with 310, 316, or 321 stainless steel sheaths, change 'SS' in the model number to '310SS', '316SS', or '321SS' respectively.
- Junction Types: Grounded (G), Ungrounded (U), and Exposed (E).
- Diameters: 1.5 mm (1/16"), 3.0 mm (1/8"), 4.5 mm (3/16"), and 6.0 mm (1/4").
- Connector Type: DTC Type Dual Connector.
- Special Options: PFA coating is available with a maximum temperature of 205°C (400°F). Custom connector types are available upon consultation with custom engineering. To order Super OMEGACLAD XL sheath, change 'N' in the model number to 'XL'.
Accessories including mating connectors and cable clamps are sold separately.
Key Product Differences
The series distinguishes variants by thermocouple alloy code (IC for Type J, CA for Type K, CX for Type E, CP for Type T), sheath material designation ('IN' for Inconel®, 'SS' for 304 SS, or specific grades like '316SS'), and junction type suffixes. Model numbers follow the format: Thermocouple Alloy - Sheath Dia. mm (inch) - Junction Type.
Specific mating connector model numbers vary by alloy:
- Type J (IRON-CONSTANTAN): DTC-J-F
- Type K (CHROMEGA™-ALOMEGA™): DTC-K-F
- Type E (CHROMEGA CONSTANTAN): DTC-E-F
- Type T (COPPER-CONSTANTAN): DTC-T-F
PDFs & Manuals