Singapore 1800 622 1156 | Intl +65 6415 5353 | Welcome to our new site - found a bug? Please report it here
OM-CP-PRTC110-Series
Differential Pressure and Thermocouple Temperature Data Logger
- This product has been discontinued. Please see OM-CP-TC101A or OM-CP-PR2000 for a potential replacement.
- 5 Year Battery Life
- Wide Temperature Range
- Accepts Thermocouple Types
OM-CP-PRTC110-Series
From
Product Overview
- Accuracy Detail Thermocouple Accuracy: ±5% FSR max at 25ºC over 1 year
- Battery life up to 5 yr
- Battery Size and Type 3.6V Li-ion
- Baud Rate 57600
- Calibration Digital calibration through software
- Data Format atm, °C, Date and time, °F, inH2O, inHg, K, kPa, mmHg bar, MPa, Pa, PSIG, °R, Torr
- Data Interface USB
- Electrical Connection Note Thermocouple Connection:Female subminiature thermocouple connector Pressure Connections:REF and IN ports via 1⁄16" ID, 5⁄32" Max OD, polyurethane tubing
- Height 0.8 in
- Length 1.6 in
- Memory Note 10,922 readings per channel; software configurable memory wrap
- Number of Measurements 2
- Operating Temperature, Max 80 °C
- Operating Temperature, Min -20 °C
- Measurement Pressure, Max 4 psi
- Selectable Pressure Range 0 to 2 inH2O
- Real Time Recording The device may be used with PC to monitor and record data in Real-time
- Relative Humidity 0 to 95% RH non-condensing
- Resolution Temperature: 0.1°C, Pressure: 0.002 inH2O
- Sampling Rate 2 Hz (2 updates/second)
- Sampling Rate Note 2 Seconds to 24 hours
- Sensor Type Diode temperature sensor, Piezoresistive Pressure Sensor
- Series ID OM-CP-PRTC110-Series
- Software XP SP3/Vista/7 and 8
- Start Modes Delayed Start, Immediate Start
- Supply Power Type Battery
- Temperature Measurement Range -20 to 80 °C
- Thermocouple Resistance, Max 1000 Ω
- Time Accuracy ±1 min/month (at 20 to 30°C)
- USB Cable Length 6 ft
- Weight 250 g
- Width 2.7 in
Supported Applications
The Omega OM-CP-PRTC110 is a differential pressure and thermocouple temperature data logger designed for factory and laboratory applications. The device measures and records up to 10,922 measurements per channel using non-volatile solid-state memory.
Key measurement functions include:
- Differential Pressure
- Thermocouple Temperature (Types J, K, T, E, R, S, B, N)
- mV input (-75 mV to 75 mV)
- Internal Channel Temperature monitoring
Operating Conditions & Performance
The OM-CP-PRTC110 operates within an ambient temperature range of -20 to 80°C (-4 to 176°F) and a humidity rating of 0 to 95% RH, non-condensing. The unit is powered by a user-replaceable 3.6V lithium battery (included), with a real-time clock module extending battery life to greater than 2 years.
Pressure Performance
The series offers two pressure ranges with corresponding resolutions and maximum pressures:
- 0 to 2 inH₂O range: Resolution of 0.002 inH₂O; Maximum Pressure -2 to 4 inH₂O
- 0 to 5 inH₂O range: Resolution of 0.005 inH₂O; Maximum Pressure -2 to 8 inH₂O
Pressure accuracy is specified as ±5% FSR max at 25°C over 1 year.
Temperature Performance
Thermocouple temperature performance varies by type. Accuracy specifications are based on a 3 m (9.8') 24 AWG thermocouple:
- Type J, K, T, E, N: Resolution 0.1°C; Accuracy ±0.5°C
- Type R, S, B: Resolution 0.5°C; Accuracy ±2.0°C
The internal channel temperature sensor provides a resolution of 0.1°C with an accuracy of ±0.5°C.
mV Input Performance
For mV input, the range is -75 mV to 75 mV with a resolution of 5μV and an accuracy of ±20μV.
Configuration Options
The OM-CP-PRTC110 series supports configurable pressure ranges and optional NIST calibration certificates. The device features ABS plastic housing measuring 41 H x 68 W x 20 mm D (1.6 x 2.7 x 0.8") plus connective tube, with a weight of 250 g (8.8 oz).
Process Connections
The logger utilizes REF and IN ports via ⅛" ID, ⅜" Max OD polyurethane tubing for pressure measurement.
Sensor Interfaces
- Female subminiature thermocouple connector for external temperature sensors
Communication & Software
Data retrieval is performed via PC serial or USB interface (interface cable required) at 57,600 baud. The system requires Windows software to operate the data logger and convert it into a real-time strip chart recorder.
- Windows software and 1.8 m (6') USB interface cable
- FDA 21 CFR part 11 compliant IQ/OQ/PQ secure software validation workbook and software package
Battery & Replacement Parts
- Replacement 3.6V lithium battery
The device includes a CE approval mark.
Key Product Differences
Variants within the OM-CP-PRTC110 series are distinguished by pressure range and NIST certification status, as detailed in the model selection table:
- 0 to 2 inH₂O range; No NIST Certificate
- 0 to 2 inH₂O range; Includes NIST Certificate (Y)
- 0 to 5 inH₂O range; No NIST Certificate
- 0 to 5 inH₂O range; Includes NIST Certificate (Y)
PDFs & Manuals
Software & Drivers
Accessories
accessories
Secure Software for Use with OM-CP Series Data Loggers
SGD4,451.28 / each
0 In Stock