Product Overview
  • Process Connection Size N/A
  • Process Connection Type N/A
  • Process Temperature, Min 0 °C
  • Sensor Type N/A
  • Series ID PHE1300-1400-2300-Series
  • Temperature Sensor Type N/A

Supported Applications

The Omega Alpha® Series Rugged Gel-Filled pH and ORP Electrodes (PHE-1300, PHE-1400, PHE-2300) are designed for field and laboratory measurements. The series supports general-purpose applications as well as specialized configurations including test tube electrodes, flat surface measurement, and rugged puncture tips.

Documented application areas include:

  • pH and ORP monitoring in meats, cheeses, fruits, and leather (specific to the PHE-2385 model).
  • Samples containing interfering ions such as zinc, copper, or sulfide (addressed by double junction models like ORE-1411 and PHE-14xx series).

Operating Conditions & Performance

The Alpha® Series operates within process temperature ranges of 0 to 100 °C (32 to 212 °F) for most epoxy and glass models, while specific Polyethersulfone variants operate from 0 to 80 °C (32 to 176 °F). Measurement capabilities cover pH ranges of 0 to 14, 0 to 13, or 0 to 12 depending on the model suffix and liquid junction type. ORP models support a range of ±2000 mV.

Electrical resistance at 25°C (77°F) varies by construction: epoxy general-purpose electrodes typically exhibit 50 to 80 MΩ, while test tube and specialized configurations may reach up to 200 MΩ. The series utilizes Ag/AgCl reference types.

Physical Dimensions

The series offers a range of physical sizes to accommodate different installation needs:

  • Diameter: 6 mm (0.24 in) to 12.5 mm (0.49 in).
  • Overall Length: 55 mm (2.2 in) to 300 mm (12.0 in).

Configuration Options

The series is configurable across multiple dimensions including housing material, liquid junction type, and electrical connection.

Housing Materials

  • Epoxy (general purpose)
  • Polyethersulfone (economical models with removable guard options)
  • Glass (rugged puncture tip for solid samples)

Liquid Junction Types

Models are available with various junction technologies to suit specific media:

  • Polypropylene liquid junction.
  • Double Polypropylene liquid junction (for interfering ions).
  • Annular Ceramic liquid junction.
  • HDPE liquid junction.
  • PTFE liquid junction (including double Annular PTFE).

Electrical Connections & Accessories

Electrodes are supplied with a BNC connector as standard. A US Standard connector is available by adding the suffix '-U' to the model number for an additional cost. Each unit includes 0.75 to 1 m (2.5 to 3') of cable and an operator's manual.

Key Product Differences

The series distinguishes models by specific geometry, material composition, and junction configuration:

  • PHE-13xx vs. PHE-14xx Series: The 1300-series generally features single liquid junctions (e.g., Polypropylene), while the 1400-series incorporates double liquid junction designs for enhanced performance in samples with interfering ions.
  • PHE-2385: A glass electrode featuring a rugged puncture tip specifically designed for solid food products like meats, cheeses, fruits, and leather.
  • PHE-1471: An epoxy electrode configured with a flat surface design for measuring samples requiring double HDPE liquid junctions.
  • PHE-2300 Series (PHE-1335): Extended length test tube electrodes (300 mm / 12.0 in) designed for extra long test tubes with Annular Ceramic liquid junctions.
  • ORE-Series: Dedicated ORP models (e.g., ORE-1311, ORE-1411) offering a ±2000 mV range; the ORE-1411 includes a double Polypropylene liquid junction for samples with zinc, copper, or sulfide.
  • Material Variants: PHE-1317 and PHE-1417 utilize Polyethersulfone construction. The PHE-1304 is an epoxy electrode with a double Annular PTFE liquid junction operating up to 80 °C (176 °F).

Accessories

consumables

10.00 pH buffer solution 500 mL (1 pint) bottle
SGD37.69 / each
45 In Stock
4.00 pH buffer solution 500 mL (1 pint) bottle
SGD34.22 / each
68 In Stock
4.00 pH buffer solution 4 L (1 gal) bottle
SGD89.89 / each
26 In Stock
10.00 pH buffer solution 4 L (1 gal) bottle
SGD94.96 / each
20 In Stock
7.00 pH buffer solution 500 mL (1 pint) bottle
SGD34.22 / each
41 In Stock
7.00 pH buffer solution 4 L (1 gal) bottle
SGD89.89 / each
45 In Stock
5 each 4, 7 and 10 buffer packs with 5 deionized water packs
SGD96.47 / each
4 In Stock
Deionized water 500 mL (1 pint) bottle
SGD42.23 / each
0 In Stock
Deionized water 4 L (1 gal) bottle
SGD105.51 / each
11 In Stock