  • Measures: Temperature, Dew Point, Relative Humidity, Wet Bulb, Air Velocity, Air Volume, Capacity
  • Lightweight, Easy to Maneuver Measurement Vane
  • Single Point Average
  • °C/°F Selectable
HHF11-Meter
From SGD 812.23
Air Velocity/Humidity/Dew Point/Wet Bulb/Air Volume Meter  HHF11-Meter HHF11-Meter
loading all models
Product Overview
  • Accuracy ± 5 %
  • Air Velocity, Min 0.3 m/h
  • Battery Size and Type Alkaline AAA
  • Cable Length 50 cm
  • Display Type LCD
  • Enclosure Temperature, Max 50 °C
  • Enclosure Temperature, Min 0 °C
  • Form factor Handheld
  • Height 6.14 in
  • Humidity Accuracy ± 3% from 10 to 90%, ± 5% above 90%
  • Length 2.44 in
  • Number of Digits 5
  • Operating Humidity 0 to 90% RH
  • Process Temperature, Max 60 °C
  • Process Temperature, Min -20 °C
  • Resolution 0.1 m/s
  • Response Time 1 Sec
  • Series ID HHF11-Meter
  • Supply Current 8 mA
  • Supply Power Note Operating Current: 5 to 8 mA
  • Temperature Accuracy ± 0.6%
  • Temperature Sensor Type Thermocouple Type K or Thermistor
  • Vane Diameter 2.9 in
  • Volumetric Flow Rate, Max 99999 CFM
  • Volumetric Flow Rate, Min 0 CFM
  • Weight 263 g
  • Width 1.1 in

Supported Applications

The Omega HHF11 series is a handheld anemometer-psychrometer designed for HVAC applications. The HHF11A model measures air velocity, humidity, dew point, wet bulb temperature, air volume, and capacity (BTU). It features a remote fan sensor with a tunable protective cap and microprocessor-based circuitry to track maximum and minimum values.

Operating Conditions & Performance

The HHF11A operates within an ambient temperature range of 0 to 50°C (32 to 122°F) with a humidity rating of less than 90% RH. The device is powered by four "AAA" batteries or a 9VDC adapter and includes auto power-off after 10 minutes of inactivity.

Performance specifications per the series data sheet include:

  • Air Velocity: Range 0.3 to 35 m/s (1 to 114 ft/s) with ±5% accuracy and a response time of 1 second.
  • Air Volume: Range 0 to 99,999 m³/min (0 to 99,999 ft³/min) with ±5% accuracy.
  • Capacity: Range 0 to 99,999 BTU/h (0 to 99,999 kcal/h) with ±3% accuracy.
  • Temperature: Range -20 to 60°C (-4 to 140°F) with ±0.6°C (1°F) accuracy.
  • Humidity: Range 0 to 100% with ±3% from 10 to 90%, and ±5% above 90% accuracy.
  • Dew Point: Range -68 to 70°C (-90 to 158°F) with ±3% from 10 to 90%, and ±5% above 90% accuracy.
  • Wet Bulb: Range -22 to 70°C (-7.6 to 158°F) with ±3% from 10 to 90%, and ±5% above 90% accuracy.

The unit weighs 263 g (9.28 oz) without batteries and has overall dimensions of 157 x 62 x 28 mm (6.18 x 2.44 x 1.1"). The measurement vane diameter is 74 mm (2.9").

Configuration Options

The HHF11 series supports the following configuration options and accessories:

  • Housing & Display: Features a jumbo LCD display with selectable units for °C/°F, %RH, m/s/ft/m (or ft/s), Kw/Btu/h, cm/inch. The keypad includes Power, MODE, ENTER, Mx/Mn, REC START, and HOLD functions.
  • Power: Operates on 4 "AAA" batteries or a 9VDC adapter; auto-sleep mode is active when the meter is off.
  • Data Management: Tracks maximum (MAX) and minimum (MIN) values. Optional software and RS232 cable are available for data transfer.
  • Calibration & Certification: The fan and meter are sold as a kit calibrated together. A NIST-traceable 4-point calibration certificate is available via the CAL-3-FLOW option.

Key Product Differences

The primary model in this series is the HHF11A, described as an air-flow meter with a lightweight measurement vane and ball-bearing fan. The device includes a hard carrying case and operation manual. Available accessories include:

  • HHF11A-VANE: Replacement vane.
  • HHF91-SW: Software and RS232 cable (also referenced as ASFT KIT in the user guide).
  • CAL-3-FLOW: NIST-traceable 4-point calibration certificate.
  • MN2400-12: Package of 12 replacement "AAA" batteries.
en-SG