CN8200-Series
1/16 DIN Universal Input Autotune Controller with Ramp & Soak
Models In Stock
- Field-Configurable Universal Inputs
- Autotuning, Direct or Reverse-Acting for Both Outputs
- User-Selectable Ramp to Setpoint
- 8 Ramp and 8 Soak Segments
CN8200-Series
From
SGD
868.52
Models In Stock
Product Overview
- Accuracy ± 0.2 %
- Accuracy Detail ± 0.2% FS, ± 1 digit
- CMRR 100 dB
- Cold Junction Compensation 0.05°C/°C ambient
- Contacts Twin bifurcated
- Control Characteristics Set point Limits: Limited to configured range for thermocouple and RTD; limited to scaled range; Alarms: Adjustable for high/low; selectable process or deviation; Rate (Derivative): 0 to 2400 seconds; Reset (Integral): 0 to 9600 seconds; Cycle Time: 0.2 to 120 seconds; Proportional Band: 1 to span of sensor; Dead band: Negative span to positive span of sensor; Hysteresis: 1 to span of sensor; Autotune Damping: Adjustable (low, normal, or high); Ramp to Set point: 1 to 9999 minutes; Autotune: Operator-initiated from front panel; Manual Control: Operator-initiated from front panel
- Cutout Dimensions 45 x 45 mm
- Depth Behind Panel 100 mm
- Display Size 9.2 mm (.36 in)
- Display Type 4 Digit LED
- Display Type Note Dual LED—4-digit, orange: process display; green: menu/parameter display; 9.2 mm (0.36")
- Electrical Connection Screw Terminal
- Enclosure Ratings IP65, NEMA Type 4X
- Events/Alarms 1 to 8
- Form factor 1/16 DIN
- Hardware and Software Requirements, Min CN8-SW (Optional Software): Minimum Hardware and Software Requirements: IBM PC or 100% compatible, Windows 95/98/NT; RS485 interface or RS232 to RS485 converter; Software Compatibility: CN8200 Series controllers; Software Capability: Supports up to 254 CN8200 Series controllers
- Height 53.3 mm
- Input Type Thermocouple, RTD, mA, Voltage
- Input Type Note Input Type: See input table on next page Digital Input: For remote setpoint, remote standby or ramp/soak run and hold Thermocouple Lead Resistance: 100 Ω maximum for rated accuracy Decimal Position: Selectable
- Length 8.21 mm
- Loops 0 to 99
- Measurement Type Current, Temperature, Voltage
- Measuring Range Type J (Iron-Constantan): -200 to 760°C, Type K (CHROMEGA®-ALOMEGA®): -270 to 1354°C, Type T (Copper-Constantan): -270 to 400°C, Type N (OMEGALLOY®) : -268 to 1300°C, Type R (Pt/13%Rh-Pt) : -50 to 1768°C, Type S (Pt/10%Rh-Pt) : -50 to 1768°C, Type B (Pt/30%Rh-Pt/6%Rh) : 0 to 1820°C, Type C (W/5%Re-W/26%Re) : 0 to 2315°C, Type E (CHROMEGA®-Constantan) : -150 to 1000°C, NNM 18% molybdenum vs nickel -06% cobalt : 0 to 1410°, Platinel II : -100 to 1232°C, RTD ((3-wire) 100 Ω Pt) : -200 to 850°C, RTD ((3-wire) 100 Ω Pt) : -199.9 to 375.0°C, 0 to 1V : Scalable (-1999 to 9999) selectable 1 to 5V : Scalable (-1999 to 9999) selectable 0 to 5V : Scalable (-1999 to 9999) selectable 0 to 10V : Scalable (-1999 to 9999) selectable 10 to 50 mV : Scalable (-1999 to 9999) selectable 0 to 50 mV : Scalable (-1999 to 9999) selectable 0 to 10 mV : Scalable (-1999 to 9999) selectable 0 to 100 mV : Scalable (-1999 to 9999) selectable 4 to 20 mA : Scalable (-1999 to 9999) selectable 0 to 20 mA : Scalable (-1999 to 9999) selectable
- Memory Backup Solid State
- Number of Inputs 1
- Operating Temperature, Max 55 °C
- Operating Temperature, Min 0 °C
- Ramp and Soak 8 Ramp & Soak
- Ramp Setpoint 1 to 9999 minutes
- Ramp/Soak Time 0 to 9999 minutes
- Relative Humidity 90% RH, non-condensing
- Repeatability ± 1 count
- Sampling Rate 10 Hz (10 updates/second)
- Series ID CN8200-Series
- Series Mode Rejection >70 dB
- Setpoint Resolution 1 count/0.1 count
- Supply Power Note 100 to 250V, 50/60 Hz (single-phase); 120 to 250 Vdc, 24 Vac/24 Vdc (optional)
- Temperature Stability 5 μV/°C Max
- Weight 226 g
- Width 53.3 mm
Supported Applications
The Omega CN8200 Series comprises 1/16 DIN universal temperature and process controllers designed for applications requiring precise autotuning, ramp-to-setpoint control, and multi-segment programming. The series supports field-configurable universal inputs including thermocouples (J, K, T, N, R, S, B, C, E), RTDs (3-wire 100 Ω Pt), Platinel II, voltage, current, and millivolt signals.
Key functional capabilities include:
- Ramp/Soak Control: Configurable for up to 8 ramp segments followed by 8 soak segments.
- Dual Display: Simultaneous Process Value (PV) and Setpoint (SV) indication with individual status LEDs.
- Remote Monitoring: Compatible with CN8-SW software for remote monitoring and control via RS232/485 communications options.
Operating Conditions & Performance
The controller operates within an ambient temperature range of 0 to 55°C (32 to 131°F) at a maximum humidity of 90% RH, non-condensing. The front panel features a NEMA 4X (IP65) enclosure rating.
Performance specifications include:
- Accuracy: ±0.2% FS, ±1 digit for rated accuracy conditions.
- Response Time: 10 Hz (100 ms).
- Hysteresis: Adjustable from 1 to span of sensor.
- Resolution: 1 count or 0.1 count depending on range selection.
The series supports a wide array of measurement ranges, including -270 to 1354°C (-454 to 2469°F) for specific thermocouple types and scalable electrical inputs from -1999 to 9999. Load resistance is limited to 100 Ω maximum for rated accuracy on analog outputs.
Configuration Options
Power Supply Options
The standard power supply supports a universal range of 100 to 250 Vac and 120 to 250 Vdc. An optional low-voltage configuration (-LV suffix) is available for 24 Vac/24 Vdc operation.
Input Types
The universal input capability covers the following sensor types:
- Thermocouples: J, K, T, N, R, S, B, C, E (including CHROMEGA®-ALOMEGA®, OMEGALLOY®, and W/5%Re-W/26%Re).
- RTDs: 3-wire 100 Ω Pt.
- Analog Signals: Voltage (0 to 1V, 1 to 5V, 0 to 5V, 0 to 10V), Current (4 to 20 mA, 0 to 20 mA), and Millivolt ranges.
Output Configurations
The series is available in single-output (CN8201) or dual-output (CN8202) models. Output types include:
- Mechanical Relay: 5 A @ 120 Vac, 3 A @ 240 Vac.
- Solid State Relay (SSR): 1 A continuous, 10 A surge @ 25°C.
- DC Pulse: 20 Vdc pulse output.
- Analog Current/Voltage: 4 to 20 mA (up to 800 Ω or 1000 Ω maximum depending on suffix), 0 to 5V, 0 to 10V, and various mV ranges.
Additional Options
The series supports a single additional option per controller. Available options include:
- Alarms: Single-alarm mechanical relay (-AL1), dual alarms with AC SSR (-AL2), or dual DC level alarms at 24 Vdc (-AL3).
- Communications: RS232 (-C2) or RS485 (-C4). The -C4 option can be configured for MODBUS® protocol and includes variants with digital inputs (switch closed, switch open, or 0/5V logic).
- Remote Setpoint: Switch-based or voltage-based remote setpoints.
- Transducer Excitation: Available at 15 Vdc (-XP1), 12 Vdc (-XP2), 10 Vdc (-XP3), or 5 Vdc (-XP4).
Key Product Differences
The CN8200 Series is differentiated by model number and output configuration:
- CN8201-(-*): Single-output ramp/soak controller.
- CN8202-(-*)-(-*): Dual-output ramp/soak controller, allowing independent selection of first and second output types (e.g., Relay + SSR).
The ordering suffix structure defines the specific configuration: <MODEL> - <FIRST OUTPUT SUFFIX> - <SECOND OUTPUT SUFFIX> - <LOW VOLTAGE SUFFIX> - <ADDITIONAL OPTION SUFFIX>. For example, a dual-output model with DC pulse and relay outputs configured for low voltage and an alarm would follow the pattern CN8202-DC1-R2-LV-AL3.
The series includes UL US and C UL US approvals. A 2-year warranty is standard, with OMEGACARE™ extended warranty programs available.