FP7002-Series

Paddlewheel Flow & Temperature Meter

  • Measures Both Flow and Temperature
  • Wide Chemical Compatibility
  • 4 to 20 mA or 1 to 5 Vdc Field Selectable Output
  • NEMA-4 Housing
FP7002-Series
From SGD 1,805.16
Paddlewheel Flow & Temperature Meter FP7002-Series FP7002-Series
loading all models
Product Overview
  • Accuracy ± 2 %
  • Electrical Output 4 to 20 mA
  • Enclosure Ratings IP65, NEMA Type 4
  • Loop Resistance, Max Ω = (V supply–12V)/0.02 A
  • Operating Pressure, Max 150 psi
  • Operating Pressure, Min 0 psi
  • Operating Pressure Note Do not exceed maximum ratings of the piping. Depending on the material of the fitting, the operating temperature/pressure may be limited by the piping and not by the sensor. For all PVC tee fittings, do not exceed 150 psig @ 27°C (80°F), 100 psig @ 38°C (100°F), 60 psig @ 49°C (120°F) or 30 psig @ 60°C (140°F), owing to thesert the tee. FP7000 sensor: 0 to 26°C (32 to 80°F) up to 150 psig; max pressure decreases 1.1 psig per each 0.56°C (1°F) above 27°C (80°F) for a max temperature of 93°C (200°F) at 18 psig maximum
  • Operating Temperature, Max 100 °C
  • Operating Temperature, Min 0 °C
  • Output Detail current
  • Pressure Drop, Max 1.1 psi
  • Pressure Drop Note max pressure decreases 1.1 psig per each 0.56°C (1°F) above 27°C (80°F) for a max temperature of 93°C (200°F) at 18 psig maximum
  • Measurement Pressure Type Gauge
  • Process Temperature, Max 93 °C
  • Process Temperature, Min 0 °C
  • Repeatability Error ±1%
  • Series ID FP7002-Series
  • Supply Voltage 12 to 18 Vdc
  • Temperature Accuracy ± 1.7 °C
  • Viscosity Range 5 cPs
The FP7002 Series Paddle-wheel Flow sensor/transmitter flow system provides a low cost, factory calibrated, simple, and easy to install solution for applications requiring a remote long distance flow 
and temperature sensor located away from the main indicating meter or control instrumentation. When ordered with an FP7000 series installation fitting, the sensor/transmitter is factory calibrated to match the flow rate of the fitting selected. Example: if you ordered an FP7002 sensor/transmitter with an FP7010  PVC fitting, the analog output of the transmitter will be factory calibrated to give 20 mA output at the max flow rate of 50 GPM and 4 mA out at 0 GPM. The analog output can be converted to 1 to 5 Vdc output in the field without re-calibrating the system. Also now included into the FP7002 design at no extra charge is an independent temperature sensor/transmitter with an industry standard 2-wire, 4 to 20 mA loop output scaled over a 0 to 100°C temperature range.