Singapore 1800 622 1156 | Intl +65 6415 5353 | Welcome to our new site - found a bug? Please report it here
RD1000-RD2000-RD3000-Series
Touch Screen Paperless Recorders with Expandable I/O
Models In Stock
- Color TFT Touch Screen Display: 4.3', 5.6' and 12.1'
- Expandable Inputs and Outputs via Plug and Play I/O Cards: RD1000/2000 Series–4 Slots RD3000 Series–16 Slots
- Analog Inputs: RD1000 Series–Up to 6, RD2000 Series–Up to 24, RD3000 Series–Up to 48
- User Friendly with Bar Graph, Numerical, Vertical or Horizontal Trend Display
RD1000-RD2000-RD3000-Series
From
SGD
7,651.79
Models In Stock
Product Overview
- Accuracy ± 0.05 %
- Accuracy Detail Voltage and Current: ±0.05%, Thermoocouple: (J, K, T, E): ±1˚C, (N, L, U, P, W5, W3, LR, A1, A2, A3, M, E, B, R): ±2˚C, RTD: ±0.4˚C (CU10: ±1.0˚C)
- Altitude,Max 2000 m
- Burnout Current 10 µA
- CMRR 120 dB
- Configuration ARM Cortex-A8, 1 GHz
- Connection Note 2 Ports (One front, One back)
- Data Interface Ethernet, Modbus
- Depth Behind Panel 171 mm
- Dielectric Strength 2300 Vac, 50/60 Hz for 1 minute between power terminal and earth
- Display Type LCD
- Enclosure Ratings IP20, IP65
- Features 19 languages including English, Japanese, Chinese (simplified, traditional), French, German, Spanish, Swedish, Danish, Italian, Polish, Russian, Dutch, Korean, Thai, Turkish, Portuguese, Brazil Portuguese and Czech
- Input Current ± 26 mA
- Input Note Sensor Lead Resistance Effect: Thermocouple: 0.32 ppm of reading/Ω, 3-Wire RTD: 2.6˚C/Ω of resistance difference of two leads (based on ˚C measurement temperature for Pt100), 2-Wire RTD: 2.6˚C/Ω of resistance sum of two leads (based on ˚C measurement temperature for Pt100); RTD Input: ±20V, Thermocouple and Voltage Input: ±65V, Current (mA) Input: ±10V
- Input Type Thermocouple, RTD, Voltage, Current
- Input Voltage ± 60 mVdc, ± 200 mVdc, ± 1 Vdc, ± 2 Vdc, ± 6 Vdc, ± 20 Vdc, ± 50 Vdc, 0.4 to 2 Vdc, 1 to 5 Vdc
- Insulation Resistance 20 MΩ @ 500 Vdc
- Isolation 1500 Vac at 50/60 Hz for 1 minute
- Keypad Functions Start/Stop Recording and turn off Display only (for quick re-start), Does not turn off Power to the unit
- Length 189 mm
- Measurement Type Universal
- Memory 256 MB Samples on 128 MB Flash Card
- NMRR 55 dB
- Operating Temperature, Max 50 °C
- Operating Temperature, Min 0 °C
- Relative Humidity 20 to 90% RH
- Relative Humidity Note 20 to 90% RH (noncondensing), maximum relative humidity of 90% RH is for ambient temperature up to 38˚C (100˚F) decreasing linearly to 50% RH at 50˚C
- RTD Type 2-, 3- or 4-wire RTD
- Sampling Rate 10 Hz (10 updates/second)
- Sensor Break Detection Sensor opened for thermocouple, RTD and mV inputs; below 1 mA for 4 to 20 mA input, below 0.25V for 1 to 5V inputs, unavailable for other inputs; Within 1 second for thermocouple, RTD and mV inputs; 0.1 second for 4 to 20 mA and 1 to 5V inputs
- Series ID RD1000-RD2000-RD3000-Series
- Shock Resistance 30m/s² (3g) for Operation, 20 g for Transportation
- Software Standard Software supplied for Historical data viewing and Configuration, Optional: Data Acquisition Studio Software, OS:Windows XP/Vista/7/8
- Storage Temperature, Max 70 °C
- Storage Temperature, Min -30 °C
- Supply Power Note 90 to 250 Vac, 47 to 63 Hz,52 VA, 26 W max; 11 to 36 Vdc, 26 VA, 26 W max (optional)
- Supply Power Type AC
- Supply Voltage 90 to 250 Vac
- Thermal Effects ±0.1 µV ±15 ppm of reading for all inputs except mA, ±30 ppm of reading for mA input
- Thermocouple Type J, K, T, E, N, R, S, U, B, L, P
- Vibration Resistance 10 to 55 Hz, 10 m/s² for 2 hours
Supported Applications
The Omega RD1000, RD2000, and RD3000 Series are color TFT touch screen paperless recorders designed for monitoring and recording process variables. These digital data acquisition devices store historical data on internal flash memory or external storage media without the use of paper charts. The series supports real-time monitoring via Windows® graphical software and includes a built-in web server to view recorder trends and digital data remotely over an Internet connection with a fixed IP address.
Operating Conditions & Performance
The RD1000/RD2000 Series measures process variables across multiple input types, including Thermocouple (J, K, T, E, B, R, S, N, L, U, P, W5, W3, LR), RTD (Pt50, Pt100, Pt200, Pt500, Pt1000, Pt150, JPT series, Cu series, Ni series), Current (±26 mA), and Voltage ranges from ±60 mV to ±50.6 V. Measurement accuracy varies by input type: ±1°C for certain thermocouples; ±2°C for 200 to 1820°C ranges; ±0.4°C, ±0.05%, or other values depending on the specific sensor and range selected.
Response time is within 1 second for thermocouple, RTD, and mV inputs, and 0.1 second for 4 to 20 mA and 1 to 5 V inputs. The units feature a 24-bit resolution and operate in ambient temperatures from 0 to 50°C (32 to 122°F). Storage temperature ranges from -30 to 70°C (-22 to 158°F). Humidity tolerance is rated at 20 to 90% RH non-condensing, with a maximum of 90% RH up to 38°C (100°F), decreasing linearly to 50% RH at 50°C (122°F).
Enclosure protection is rated IP65 (NEMA 4X) water-resistant. Mechanical ratings include a shock rating of 30 m/s² (3g) for operation and 20 g for transportation, with vibration resistance from 10 to 55 Hz at 10 m/s² for 2 hours.
Configuration Options
The series offers expandable input and output capabilities via plug-and-play I/O cards. Configurable options include:
- Display Sizes: Models feature 4.3", 5.6", or 12.1" color TFT touch screens.
- I/O Expansion: Supports up to 48 analog inputs and 96 optional external channels using cards such as RD1000-3AI, RD1000-6AI, RD1000-6R, RD1000-6DI, RD1000-3R-3DI, and RD1000-6AO.
- Memory & Storage: Includes 256 MB internal flash memory, an on-board SD card slot for internal storage, and USB host ports to download data or connect a printer. External storage is available via the USB slot.
- Communications: Standard Ethernet (IEEE 802.3 - 10/100 Base T) with optional RS232/422/485 serial communications modules.
- Power Supply: Operates on 90 to 250 Vac, 47 to 63 Hz (52 VA; 26 W max), or optionally 11 to 36 Vdc (26 VA; 26 W max).
- Firmware Options: Available suffixes include -FW1 (extra math, external channels, batch, FDA 21 CFR Part 11); -FW2 (custom edited display and Panel Studio editing software); and -FW3 (includes all items in Plus versions 1 and 2).
- Mounting Options: Suffixes include -1 for panel mount without power cord; -2 through -6 for portable configurations with various regional power cords (standard, VDE, SAA, BS, GB) and switches.
Key Product Differences
The series is divided into three model families distinguished by physical dimensions and channel capacity. The RD1000/RD2000 Series measures 144 H x 144 W x 189 mm D (5.67 x 5.67 x 7.44"). The larger RD3000 Series measures 288 H x 288 W x 189 mm D (11.34 x 11.34 x 7.44").
Model numbers follow the format: RD1000/RD2000/RD3000 - <Firmware Option> - <Mounting Option>. For example, RD2000-FW1-2 indicates an RD2000 unit with Plus version 1 firmware and a portable mounting option. Output signals are configurable to include 4 to 20 mA, 0 to 20 mA, 0 to 5 V, 1 to 5 V, or 0 to 10 Vdc.
PDFs & Manuals
Accessories
accessories
TRANSCEND FLASH MEMORY CARD
/ each