Need assistance? Call us: 1-800-663-4209
Series-IEFConfiguration
Electromagnetic Flow Transmitter for 4-36" Pipes, Adjustable Installation
Transmisor de flujo electromagnético para tuberías de 4 a 36 Pulgada, instalación ajustable- Meet application requirements with field configurable setup displays (-LCD integral option or remote accessory A-IEF-DSP), which accommodate a variety of application configurations with one model through multiple display configurations i.e. pipe size, pipe material, liquid type, analog output, pulse/frequency output, alarm outputs, communication outputs, damping, and calibration factor
- Maintain system efficiency with high performance accuracy that is maintained through changes in temperature, density or viscosity
- Quick and easy ordering and set up with Setup Wizard and installation tool that are simple to use and allow for precise installation
- Save time with accessory setup kit A-IEF-KIT that ensures exact installation application depth with included thickness gage and measuring tape
- Reduced costs, long product life, and minimal maintenance requirements with no moving parts to wear or break and electrodes that discourage fouling
- Minimize installation costs with isolation valve accessory options to allow for installation in operational systems via hot-tap kit or easy removal without system downtime
- Required documents included with NIST traceable pass/fail verification certificate included standard for Carbon Steel Schedule 40 pipes sized 4" (102 mm), 6" (150 mm), 8" (200 mm)
Product Overview
- Accuracy ± 1 %
- Applications Agricultural & Hydroponics Applications, Boilers, Chemical Refineries, Chemicals, Fluid Measurement and Control, Oil, Pump Control, Water Quality Monitoring
- Conductivity > 20 µS/cm
- Control Output Alarm
- Display Range 0 to 100% Glycol Display Selectable
- Linear Flow Rate, Max 20 ft/s
- Linear Flow Rate, Min 0 ft/s
- Materials Aluminum
- Materials, Wetted Polymer, Silicon, Stainless Steel
- Media Compatibility Conductive liquids, Corrosive chemicals / acids / bases
- Operating Temperature, Max 160 °F
- Operating Temperature, Min -20 °F
- Output Detail (1) Analog: 4-20 mA, 0-5 V, 0-10 V or 2-10 V (display selectable); (1) Pulse/Frequency: 0-15 V peak pulse, 0 to 500 Hz or scalable pulse output (display selectable); (2) Alarm: (1) Empty pipe detection or minimum/maximum velocity, (display selectable); (1) Reverse flow output indication
- Output Signal Current, Voltage, DC Pulse
- Pressure Drop, Max 0.1 psi
- Pressure Drop Note < 0.1 psi at 12 ft/s in 4" (101.6 mm) and Larger Pipe
- Pressure Limits Up to 400 psi
- Process Connection Size 1 in
- Process Temperature, Max 250 °F
- Process Temperature, Min 15 °F
- Series ID Series-IEF
- Storage Temperature, Max 185 °F
- Storage Temperature, Min -40 °F
- Straight Run Requirements >10 Diameter Upstream, >5 Diameter Downstream
- Supply Power Type AC/DC
- Supply Voltage 12 to 42.4 Vdc, 0.25 A @ 24 Vdc; 12 to 36 Vac
¡La pantalla remota A-IEF YA ESTÁ DISPONIBLE!
El Transmisor de flujo electromagnético de inserción Serie IEF es un caudalímetro de inserción ajustable que utiliza tecnología electromagnética para medir con precisión y fiabilidad la velocidad del fluido, además de ofrecer varias salidas de señal continuas. Esta serie está diseñada específicamente para ofrecer un rendimiento superior junto con una instalación y uso sencillos. Una unidad es ajustable para adaptarse a tamaños de tubería de 4 a 36" (102 a 914 mm) y ofrece varias opciones de salida, incluyendo protocolo de comunicación seleccionable BACnet MS/TP o Modbus® RTU sobre RS-485 de 2 hilos, además de las salidas estándar analógica, de frecuencia y de alarma.
Aplicaciones del producto
- Agua de alimentación de calderas
- Agua enfriada
- Agua de condensador en circuito abierto y cerrado
- Sistema de riego
- Flujo de proceso y refrigerante
- Remediación de aguas subterráneas
- Procesamiento químico
- Protección de bombas
- Aguas residuales
- Minería
PDFs & Manuals