Need assistance? Call us: 1-800-663-4209
IOLinkConv
IO-Link Converters
Models In Stock
- Converts 4–20 mA current or 0–10 V voltage signals into accurate IO-Link process data.
- Rugged over-molded housing with IP65, IP67, and IP68 ratings for harsh environments.
- Compact in-line M12 connection allows direct sensor integration and easy installation.
- High-resolution 13/14-bit accuracy with LED indicators for power, IO-Link, and analog status.
IOLinkConv
From
$
185.95
Models In Stock
Product Overview
- Accuracy ± 0.5 %
- Height 15 mm
- Length 57.8 mm
- Number of Channels, Input Analog: 1
- Number of Channels, Output Digital: 1
- Operating Temperature, Max 70 °C
- Operating Temperature, Min -40 °C
- Output Signal Digital
- Series ID IOLinkConv
- Storage Temperature, Max 80 °C
- Storage Temperature, Min -40 °C
- Supply Power Type DC
- Supply Voltage 18 to 30 Vdc
- Width 15 mm
Supported Applications
The Omega IF-IOL Series IO-Link Converters serve as compact analog-to-digital interface devices, connecting current or voltage sources to an IO-Link master. These converters enable communication with industrial sensors by translating analog signals into digital process data for transmission over the IO-Link protocol.
- Connects directly to a sensor or in-line within existing cabling runs.
- Serves as an interface between 4 mA to 20 mA current sources and IO-Link masters (IF-IOL-001).
- Serves as an interface between 0 V to 10 V voltage sources and IO-Link masters (IF-IOL-002).
Operating Conditions & Performance
The series operates within a specified ambient temperature range of -40 °C to +70 °C (-40 °F to +158 °F) and supports storage temperatures from -40 °C to +80 °C (-40 °F to +176 °F). The device is rated for 90 % at +70 °C maximum relative humidity (non-condensing).
- Power Supply: 18 Vdc to 30 Vdc at 50 mA maximum.
- Accuracy: 0.5 %.
- Resolution: IF-IOL-001 provides 14-bits; IF-IOL-002 provides 13-bits.
- Mechanical Ratings: Meets IEC 60068-2-27 requirements (Shock: 15 G, 11 ms duration, half sine wave) and IEC 60068-2-6 requirements (Vibration: 10 Hz to 55 Hz, 0.5 mm amplitude, 5 minutes sweep, 30 minutes dwell).
Configuration Options
The IF-IOL Series is available in two primary configurations based on the input signal type:
- IF-IOL-001: Compact analog current to IO-Link device converter for 4 mA to 20 mA inputs.
- IF-IOL-002: Compact analog voltage to IO-Link device converter for 0 V to 10 V inputs.
The rugged over-molded design features an enclosure rating of IP65, IP67, and IP68; NEMA/UL Type 1. Electrical connections utilize integral male/female 4-pin M12/Euro-style quick disconnects (M12 X 1 - 6g male, M12 X 1 - 6H female). The housing materials consist of nickel-plated brass for the coupling and PVC translucent black for the connector body.
Communication Parameters
- IO-Link Revision: V1.1.
- Port Class: A.
- Bit Rate: 38400 bps.
- Minimum Cycle Time: 3.6 ms.
- SIO Mode, Smart Sensor Profile, Block Parameterization, and Data Storage are supported.
Key Product Differences
The primary distinction between the two models is the input measurement type:
- IF-IOL-001 (Current Model): Accepts 4 mA to 20 mA. Default values are SP1: 0.004 A and SP2: 0.02 A.
- IF-IOL-002 (Voltage Model): Accepts 0 V to 10 V. Default values are SP1: 0 V and SP2: 10 V.
Both models share identical physical dimensions of 57.8 mm [2.27 in] length, 27.9 mm [1.1 in] width, and 15.0 mm [0.59 in] height. Overcurrent protection is required per the supplied table based on supply wiring AWG (e.g., 5.0 A for 20 AWG; 3.0 A for 22 AWG). A shielded cable is required on the female sensor side, with the shield tied to the blue wire.
Accessories
accessories
High Accuracy oil filled Wet/Dry and Wet/Wet Differential Pressure Transducers
From $1,271.50
0 In Stock
Heavy Duty Pressure Transducers with Sealed SS Construction
From $964.20
0 In Stock
Show Ratings & Reviews