Skip to search Skip to main content Skip to navigation

Taiwan 0809 090 375 | Intl +65 6415 5353 | Welcome to our new site - found a bug? Please report it here

We noticed you are in , please visit your local site by clicking the below link for regional offers and support.

XW-EDA-Series

XW-EDA Universal Process and Temperature Wireless Transmitter

  • Wireless communication up to 1000 m* (3280’) outdoor and 100 m* (328’) indoor
  • Wide range of measurements supported (4-20 mA, 0-10 V, mV, TC, and RTD)
  • Data Assurance and logging up to 4096 readings per measurement
  • Direct USB configuration for easy set-up
XW-EDA-Series
From
XW-EDA Universal Process and Temperature Wireless Transmitter XW-EDA-Series XW-EDA-Series
loading all models
Product Overview
  • Accuracy ± 0.4 °C, ± 0.3 °C, ± 10 µA, ± 5.0 mV
  • Accuracy Detail Thermocouple: J: -210°C to 1200°C: 0.4°C K: -160°C to 1372°C: 0.4°C T: -190°C to 400°C: 0.4°C E: -220°C to 1000°C: 0.4°C N: -100 to 1300°C: 0.4°C R: 40°C to 1788°C: 0.5°C S: 100°C to 1768°C: 0.5°C B: 640°C to 1820°C: 0.5°C C: 0°C to 2320°C: 0.4°C RTD: 385, 4 Wire: -200°C to 850°C: 0.3°C 385, 3 Wire: -200°C to 850°C: 0.3°C 385, 2 Wire: -200°C to 850°C: 0.6°C 392, 4 Wire: -200°C to 660°C: 0.3°C 392, 3 Wire: -200°C to 660°C: 0.3°C 392, 2 Wire: -200°C to 660°C: 0.6°C 3916, 4 Wire: -200°C to 660°C: 0.3°C 3916, 3 Wire: -200°C to 660°C: 0.3°C 3916, 2 Wire: -200°C to 660°C: 0.6°C Process Current: 0-24 mA: ±10 uA Voltage: 0-10 V: ±5.0 mV Voltage: 0-1 V: ±0.5 mV Voltage: 0-100 mV: ±0.05 mV
  • Approvals ECCN, EAR99, EMC 2014/30/EU, LVD 2014/35/EU, RED 2014/53/EU
  • Battery life up to 5 yr
  • Battery Operating Temperature -20 to 60 °C
  • Compatibility Thermocouple, RTD, and Process
  • Data Interface Wireless, USB
  • Electrical Connection M12 4 pin Male
  • Electrical Output N/A
  • Enclosure Ratings IP65, NEMA 4
  • Form factor Field Mountable
  • Height 5.35 in
  • Input Range -160 to 1372 °C
  • Input Range Note Thermoocouple: J -210°C to 1200°C, K -160°C to 1372°C, T: -190°C to 400°C, E: -220°C to 1000°C, N: -100°C to 1300°C, R: 40°C to 1788°C, S: 100°C to 1768°C, B: 640°C to 1820°C, C: 0°C to 2320°C RTD: 385: -200°C to 850°C, 392 and 3916: -200°C to 660°C, Current: 0-24mA, Voltage: 0-10Vdc, 0-1Vdc, 0-0.1Vdc
  • Length 1.56 in
  • Materials Polycarbonate
  • Number of Channels 16
  • Operating Temperature, Max 70 °C
  • Operating Temperature, Min -20 °C
  • Operating Temperature Note CR2032 Battery: -20 to 60°C, Alkaline Battery: -18 to 55°C
  • Process Temperature, Max 1372 °C
  • Process Temperature, Min -160 °C
  • Relative Humidity 90% RH non-condensing
  • Sensor Type Temperature, Process
  • Series ID XW-EDA-Series
  • Software Compatible with SYNC by Omega and OEG
  • Supply Power Note Power: 0.8 W maximum, Battery: Two C-cell 1.5Vdc Alkaline Battery (included), Optional AC Power Adaptor (UNIV-AC-100/240-5-M8): Nominal Output: 5 Vdc @ 0.6 A, Input: 100 to 240 Vdc, 50/60 Hz
  • Supply Power Type AC/DC/Battery
  • Supply Voltage 5 to 36 Vdc, 24 Vac
  • Width 3.23 in
  • Wireless Receiver Sensitivity -96 dBm

Supported Applications

The Omega XW-EDA and XW-EDA-PRO series are long-range wireless transmitters designed to interface analog process signals and precision temperature sensors, including thermocouples (TC) and Resistance Temperature Detectors (RTD). The devices provide a wireless link for monitoring industrial processes in demanding indoor environments or harsh outdoor conditions. Data is transmitted via IEEE 802.15.4 compliant communication at 2.4 GHz to a ZW-REC Wireless Receiver, which connects to an Ethernet network to serve active web pages and display data.

The XW-EDA model supports thermocouples, RTDs, and precision process inputs (current and voltage). The XW-EDA-PRO variant functions as both a wireless end device and an Edge Controller, adding discrete I/O capabilities for triggering alarms, monitoring switches, or controlling other equipment via 2 discrete open drain digital inputs/outputs.

Operating Conditions & Performance

The series operates within specific environmental limits depending on the power source. The base unit operating range is -20 to 70°C (-4 to 158°F) at 90% RH non-condensing. When powered by a CR2032 battery, the limit is -20 to 60°C (-4 to 140°F); with alkaline batteries, it is -18 to 55°C (-0.4 to 131°F). The enclosure is constructed of polycarbonate and rated NEMA 4 (IP65).

Wireless communication utilizes a star topology on the 2.4 GHz band (2400 to 2483.5 MHz) with 16 channels, offering a transmit power of 9.5 dBm and receiver sensitivity of -96 dBm. Range is up to 1000 m* (3280') outdoor and 100 m* (328') indoor without obstruction.

Measurement accuracy varies by sensor type as documented in the specification tables:

  • Thermocouples: Types J, K, T, E, N, C offer ±0.4°C; Types R, S, B offer ±0.5°C.
  • RTDs (Pt100/Pt1000): 385 and 392 types with 4-wire or 3-wire configurations provide ±0.3°C; 2-wire configurations provide ±0.6°C.
  • Process Inputs: Current (0-24 mA) accuracy is ±10 uA; Voltage ranges from 0-10 V to 0-100 mV offer accuracies ranging from ±5.0 mV down to ±0.05 mV.

Data assurance includes logging up to 4096 readings per measurement. Battery life is rated for up to 5 years with a frequency of 1 reading per 10 minutes using two included C-cell alkaline batteries, backed by an included CR2032 lithium battery for RTC back-up only.

Configuration Options

The series supports configuration across sensor types, power options, and connectivity accessories:

  • Sensor Inputs: Thermocouple (Types J, K, T, E, N, R, S, B, C), RTD (Pt100/Pt1000 in 2-, 3-, or 4-wire configurations), Current (0-24 mA), and Voltage (0-1 V to 0-10 V).
  • Power Supply: Accepts 5 to 36 Vdc or 24 Vac ±10%. An optional Safety Qualified AC Power Adaptor provides nominal output of 5 Vdc @ 0.6 A from a 100 to 240 Vdc, 50/60 Hz input.
  • Connectivity: Direct USB configuration is supported. The XW-EDA-PRO includes an M12 4-pin male connector for discrete I/O and probe connections; the standard XW-EDA requires a cable for TC or RTD probe connection.

Key Product Differences

The series consists of two distinct models:

  • XW-EDA: Long-range wireless end device configured for use with Dual TC, RTD, and Process inputs. It relies on external cabling to connect probes.
  • XW-EDA-PRO: Long-range wireless end device and Edge Controller that integrates the M12 4-pin male connector directly into the unit. This variant enables direct connection of compatible M12 Series Thermocouple Probes, PR-Series RTD Probes, or field-mountable connectors without intermediate cabling for sensor attachment.

Compatible accessories include ZW-REC Wireless Receivers, universal AC adaptors with M8 connectors (UNIV-AC-100/240-5-M8), and a range of probes such as the M12 Series (6" length) or multi-length M12M Series for thermocouples, and PR-21A, PR-22, and PR-23 series RTD probes. Specific cable assemblies are available to bridge connections between sensors and transmitters where required.

Accessories

cables

M12 Cables with Field Mountable Connectors for Resistance Sensors (RTDs)
TWD2,417 / each
38 In Stock
M12 Cables with Field Mountable Connectors for Resistance Sensors (RTDs)
TWD2,658 / each
12 In Stock
DC Cable Assemblies for Probes, Sensors and Transmitters
TWD1,739 / each
27 In Stock
Field Mountable M8 and M12 Connectors
TWD718 / each
30 In Stock
Field Mountable M8 and M12 Connectors
TWD739 / each
814 In Stock

signal conditioners

ZW Series Receiver
TWD20,442 / each
0 In Stock
en-TW
en_TW
Save Configuration