Netherlands 07077 03815 | Intl +31 (0) 7077 03815 | Welcome to our new website, found an issue or bug? Please report it here
Back To Top
Load More Items from this family (11) ...
[+]
DIN Rail Signal Conditioners
Added to Your Shopping Basket
| Product Number | Input Type |
|---|---|
|
|
Current, Voltage
|
The DMD4059 Series converts wheatstone strain bridge sensors, pressure transducers, or load cell signals into process current or voltage. Offered with AC or DC Power.
| Product Number | Input Type |
|---|---|
|
|
Voltage
|
The TXDIN70 series provide two channel transmitters or isolators with 4-20 or 0-20 mA output. Programmable input types with TXDIN70-DISPLAY accessory (sold separately)
| Product Number | Input Type | Supply Voltage | Voltage Measurement Range |
|---|---|---|---|
|
|
Thermocouple, RTD, Voltage
|
100 to 240 Vac, 24 Vdc
|
0 to 20 mV, 0 to 60 mV, 0 to 100 mV, 0 to 1V, 0.2 to 1V
|
|
|
Thermocouple, RTD, Voltage
|
24 Vdc
|
0 to 20 mV, 0 to 60 mV, 0 to 100 mV, 0 to 1V, 0.2 to 1V
|
The DRST-CM is a programming display for DRST-AC, DRST-DC, DRST-UN & DRST-UR. Supports Modbus over RS-485. Monitors process value on built in display.
| Product Number | Display Type |
|---|---|
|
|
N/A
|
TXDIN1600S strain gage/load cell transmitter accepts 0.2 to 7.5 mV/V inputs with 5V excitation. Universal current, bipolar voltage output. Remote tare, front panel config.
| Product Number | Input Type |
|---|---|
|
|
Four Wire Bridge Ratiometric
|
The DRF-LC Series Conditioners are load cell input with 0-10V or 4-20mA output. For load cells with 1, 2, or 3 mV/V output. Full scale at 10, 20, or 30mV. Pre-tare jumpers
| Product Number | Voltage Measurement Range |
|---|---|
|
|
0 to 20 mV dc
|
|
|
0 to 30 mVdc
|
The DRSL-SP2 is a repeater/splitter that isolates and converts 1 process input to 2 process outputs. DIP switch selectable ranges. Slim housing, high accuracy (0.05%)
| Product Number | Input Type |
|---|---|
|
|
Voltage, Current
|
The DRST-FR converts frequency/pulse inputs to a 4-20mA or 0-10V DC output. PNP/NPN output, relay output. Universal power supply. Configurable with TXUN-KIT device.
| Product Number | Input Type |
|---|---|
|
|
Frequency
|
The DRSL-TC Series are isolated or non-isolated thermocouple input signal conditioners. Accepts Type J and Type K TC's. DIP switch selectable ranges, slim housing.
| Product Number | Input Type |
|---|---|
|
|
Thermocouple
|
|
|
Isolated thermocouple
|
The DRSL-RTD is either isolated or non-isolated with 2, 3, or 4-wire Pt100 RTD input. Pre-calibrated temp ranges selectable via DIP switch. Slim housing, high accuracy.
| Product Number | Accuracy |
|---|---|
|
|
± 0.1 %
|
|
|
± 0.05 %
|
The DRSL-RTD-LP is a 2, 3, or 4-wire PT100 RTD input conditioner. Output loop powered with high accuracy and slim housing. Pre-calibrated temp range DIP switch selected.
| Product Number | Input Type |
|---|---|
|
|
RTD
|
| Product Number | Input Type |
|---|---|
|
|
Thermocouple, RTD,Thermistor, Resistance, Potentiometer, Current, Voltage
|
The DRSL-U is a universal input conditioner that accepts thermocouple, RTD, resistance, potentiometer, voltage or current input. Configured w/ DRSL-DISPLAY programmer.
| Product Number | Input Type |
|---|---|
|
|
Thermocouple, RTD, Resistance, Potentiometer, Current, Voltage
|
The DRSL-DC1-DC2 Conditioners have a DC current and voltage input and isolated and converted DC current and voltage output. DIP switch selectable range. 0.05% accuracy
CCT DIN rail conditioners that accept various input signals, such as voltage and current, frequency, temperature (TC and RTD), and provide 0/4 to 20 mA, or 0 to 10 Vdc.
| Product Number | Current Measurement Range | Frequency Measurement Range | Input Type | Supply Voltage | Temperature Measurement Range | Voltage Measurement Range |
|---|---|---|---|---|---|---|
|
|
0 to 50 mA dc
|
N/A
|
Voltage, Current
|
110 Vac
|
N/A
|
18 Vdc Max
|
|
|
N/A
|
N/A
|
Voltage
|
110 Vac
|
N/A
|
0 to 20 mV dc
|
|
|
N/A
|
N/A
|
AC Voltage
|
110 Vac
|
N/A
|
0 to 10 Vac
|
|
|
N/A
|
N/A
|
Voltage
|
110 Vac
|
N/A
|
0 to 100 Vdc
|
|
|
N/A
|
Min: 0 to 70 Hz, Max: 0 to 125 Hz
|
Frequency
|
110 Vac
|
N/A
|
N/A
|
The DRSP-I Series are DC current splitters that take one 4-20mA input to two 4-20mA outputs w/ AC or DC power. Zero and span adjustments for each output, status LEDs.
| Product Number | Input Type | Supply Power Type |
|---|---|---|
|
|
Current
|
AC
|
The LDX-D is a DIN rail mount AC LVDT transducer that operates on 10-30Vdc power with selectable process outputs. Adjustable signal polarity, span, and offset.
| Product Number | Input Type |
|---|---|
|
|
AC Voltage
|
TXDIN1600 series has a universal thermocouple, RTD, or process input and 4-20mA output. Configuration via USB cable (sold separately). Push button user trim, relay output
The DRG-SC Series Conditioners have models with TC, RTD, Pot, Freq., AC/DC Voltage/Current, Strain/Bridge inputs and field configurable outputs from 0-5V, 0-10V, 0-20mA.
| Product Number | Input Type |
|---|---|
|
|
Voltage, Current (bipolar)
|
The DRSL-TEMP is an output loop powered temperature signal conditioner. Accepts Type J, Type K, or 2, 3 or 4 wire Pt100 RTD input. Slim housing, high accuracy.
| Product Number | Input Type |
|---|---|
|
|
Thermocouple, RTD
|
DIN Rail Signal Conditioners
DIN Rail Signal Conditioners support data acquisition workflows by helping ...