DRSL-SP2-Rptr-Spltr

DIN Rail Isolated Repeater/Splitter for Process Signals.

  • Isolation and Conversion of Process Voltage or Current Signals
  • Splitter Function: 1 Process Input–2 Process Outputs
  • Power Supply and Signal Isolator for 2-Wire Transmitter
  • Slimline Housing–Only 6 mm (0.24') Wide
DRSL-SP2-Rptr-Spltr
From  300,06
DIN Rail Isolated Repeater/Splitter for Process Signals. DRSL-SP2-Rptr-Spltr DRSL-SP2-Rptr-Spltr
loading all models
Product Overview
  • Approvals CE, UL, RoHS
  • Calibration Temperature, Max 28 °C
  • Calibration Temperature, Min 20 °C
  • Electrical Output 0 to 20.5 mA
  • EMC Immunity Note Extended EMC Immunity NAMUR NE 21, A Criterion, Burst: <±1% of span
  • EMC Standard NAMUR NE 21
  • Enclosure Ratings IP20
  • Height 113 mm
  • Installation Pollution degree 2 and measurement/overvoltage category II
  • Isolation Isolation: Input/output 1/output 2/supply;Isolation Voltage (Test): 2.5 kVac;Isolation Voltage (Working):300 Vac
  • Length 115 mm
  • Load Resistance Current Output : 23 mA/300 Ω max;Voltage Output : >10 kΩ min
  • Mounting DIN Rail 35 mm Standard, EN 60715
  • Noise Calibration >60 dB
  • Operating Temperature, Max 70 °C
  • Operating Temperature, Min -25 °C
  • Output Value Splitter
  • Power Consumption 1.2 W, Internal - max 0.65 W
  • Relative Humidity 0 to 95% RH (non-condensing)
  • Screw Terminal Torque 0.5 Nm
  • Span, Max Corresponds to the presently selected DIP switch output range
  • Stability Load Stability: ≤0.01% of span/100 Ω
  • Storage Temperature, Max 85 °C
  • Storage Temperature, Min -40 °C
  • Supply Power Type DC
  • Voltage Loss <1.5 V
  • Weight 70 g
  • Width 6.1 mm
  • Wire Gauge 26 to 12 AWG
The DRSL-SP2 isolated signal conditioner/splitter provides a competitive choice in terms of both price and technology for galvanic isolation of process voltage or current signals to SCADA systems or PLC equipment. Two process outputs are provided which mirror the single process input.
The DRSL-SP2 can be used for signal conversion of standard process voltage or current signals into two individual analog signals. The unit offers 4-port isolation, provides surge suppression and protects control systems from transients and noise. The DRSL-SP2 also eliminates ground loops and can be used for measuring floating signals. Low power consumption facilitates DIN rail mounting without the need for any air gap. Factory calibrated measurement ranges are easily configured via DIP switches. When the input is configured for 2-wire transmitter mode, the DRSL-SP2 provides the current loop supply voltage. The unit operates over a wide temperature range from -25 to 70°C (-13 to 158°F).

Accessories

installation hardware

€ 8,41 / each
0 In Stock
POWER RAIL FOR DRSL SERIES
€ 184,34 / each
0 In Stock

meters/controllers

PWR CONN FOR DRSL SERIES CE
€ 131,62 / each
0 In Stock
en-NL
en_NL
Save Configuration