Skip to search Skip to main content Skip to navigation

Netherlands 07077 03815 | Intl +31 (0) 7077 03815 | Welcome to our new site - found a bug? Please report it here

We noticed you are in , please visit your local site by clicking the below link for regional offers and support.

DRSL-DC1-DC2-Srs-Sig-Cond

DIN Rail Conditioner Series with Process Input, High accuracy

  • Isolation and Conversion of Process Voltage or Current Signals
  • Power Supply and Signal Isolator for 2-Wire Transmitter
  • Slimline Housing—Only 6 mm (0.24') Wide
  • Multiple Signal Ranges (DIP-Switch Selectable)
DRSL-DC1-DC2-Srs-Sig-Cond
From  237,07
DIN Rail Conditioner Series with Process Input, High accuracy DRSL-DC1-DC2-Srs-Sig-Cond DRSL-DC1-DC2-Srs-Sig-Cond
loading all models
Product Overview
  • Accuracy ± 0.05 %
  • Approvals CE, UL, RoHS
  • Calibration Temperature, Max 28 °C
  • Calibration Temperature, Min 20 °C
  • Conversion Rate 1:1
  • Current Measurement Range 0 to 20.5 mA
  • Electrical Output 0 to 20.5 mA
  • EMC Immunity Note Extended EMC Immunity NAMUR NE 21, A Criterion, Burst: <±1% of span
  • EMC Standard NAMUR NE 21
  • Enclosure Ratings IP20
  • Height 113 mm
  • Installation Pollution degree 2 and measurement/overvoltage category II
  • Length 115 mm
  • Load Resistance Current Output: 23 mA/600 Ω max
  • Mounting DIN Rail 35 mm Standard, EN 60715
  • MTBF 284 yrs
  • Noise Calibration >60 dB
  • Operating Temperature, Max 70 °C
  • Operating Temperature, Min -25 °C
  • Output Value Process
  • Relative Humidity 0 to 95% RH (non-condensing)
  • Response Time < 7 ms
  • Response Time Note Response Time (0 to 90%, 100 to 10%): <7 ms
  • Screw Terminal Torque 0.5 Nm
  • Stability Load Stability: ≤0.01% of span/100 Ω
  • Storage Temperature, Max 85 °C
  • Storage Temperature, Min -40 °C
  • Supply Power Type DC
  • Supply Voltage 16.8 to 31.2 Vdc
  • Temperature Coefficient <±0.01% of span/°C
  • Weight 70 g
  • Width 6.1 mm
  • Wire Gauge 26 to 12 AWG
The DRSL-DC2 isolated DIN rail signal conditioner provides a competitive choice in terms of both price and technology for galvanic isolation of process voltage or current signals to SCADA systems or PLC equipment. The DRSL-DC2 can be used for signal conversion of standard process voltage or current signals. The unit offers isolation between input, output and supply, provides surge suppression and protects control systems from transients and noise.
The DRSL-DC2 also eliminates ground loops and can be used for measuring floating signals. Low power consumption facilitates DIN rail mounting without the need for any air gap. Factory calibrated measurement ranges are easily configured via DIP switches. When the input is configured for 2-wire transmitter mode, the DRSL-DC2 provides the current loop supply voltage. The unit operates over a wide temperature range from -25 to 70°C (-13 to 158°F).

Accessories

installation hardware

MODULE STOP FOR DRSL SERIES
€ 8,41 / each
0 In Stock
POWER RAIL FOR DRSL SERIES
€ 184,34 / each
0 In Stock

meters/controllers

PWR CONN FOR DRSL SERIES CE
€ 131,62 / each
0 In Stock
en-NL
en_NL
Save Configuration