Need assistance? Call us: 1-800-663-4209
SP-014-Series
Omega Link M12 Modular Smart Probe Analog Process interface with I/O
Models In Stock
This item
has been discontinued. We are retiring the Omega Link product line and
transitioning to SensoScientific — the industry’s most
advanced wireless monitoring platform, now a key part of our unified DwyerOmega
portfolio.
SP-014-Series
From
$
200.53
Models In Stock
Product Overview
- Approvals CE, UKCA
- Configuration Configurable via Omega Link Smart Interface and SYNC configuration software
- Digital Input VinHighThreshold = 2.2 VMAX, VinLowThreshold = 0.3 VMIN, VinMAX = 30 VDC
- Digital Output 2x Open Drain 100 mA max, VMAX = 30 VDC
- Enclosure Ratings IP67
- Input Control Signal Current Loop: 4 to 20 mA, Voltage: 0 to 1.0 Vdc, 0 to 2.0 Vdc
- Input Note ON: 1.0 Vdc, OFF: 0.7 Vdc, Internal Pull Up/Down: 1.5k to 3.0 Vdc, Comparator (Pulse) Input: 100 mV, 500 mV, 1.0 Vdc, 2.0 Vdc
- Length 96.7 mm
- Number of Channels 3
- Number of I/O 2
- Operating Temperature, Max 85 °C
- Operating Temperature, Min -40 °C
- Series ID SP-014-Series
- Software Compatible with OEG, SYNC, and OMEGA Cloud
- Supply Power Type DC
- Supply Voltage 2.8 to 3.3 Vdc
- Width 22.1 mm
Supported Applications
The Omega SP-014 Series is a modular, smart sensing device designed to integrate process signals into the Omega Link Ecosystem. It functions as an analog process interface with I/O capabilities for data acquisition and monitoring tasks.
- Process signal integration via 3 independent inputs configurable as Current Loop (20 mA), Voltage (1.0 VDC or 2.0 VDC).
- Mixed-mode operation measuring one process input alongside a digital pulse input for rate, pulse width, duty cycle, or counting.
- Data and event logging supporting over 10,000 samples via SYNC software configuration.
Operating Conditions & Performance
The SP-014 Series operates within an ambient temperature range of -40 to 85°C (-40 to 185°F) and requires a power supply between 2.8 VDC and 3.3 VDC (excitation voltage: 3.3 VDC). The device achieves IP67 enclosure rating when mated.
Analog Input Performance
- Current Loop: Range 0 - 24 mA, Resolution ±0.1 mA, Accuracy ±0.2 mA (Input Impedance: 50 ohm).
- Voltage (Low): Range 0 - 1.0 VDC, Resolution ±10 mV, Max Input 1.20 VDC, Accuracy ±10 mV (Input Impedance: 100k ohm).
- Voltage (High): Range 0 - 2.0 VDC, Resolution ±10 mV, Max Input 2.50 VDC, Accuracy ±20 mV (Input Impedance: 100k ohm).
Digital Input Performance
- Frequency (Rate): Range 0.01 Hz to 100 Hz with T_PW MIN = 200 uS, Accuracy ±0.5%.
- Frequency (High Rate): Range 100 to 1000 Hz with T_PW MIN = 200 uS, Accuracy ±1 Hz averaged over 1 sec.
- Counter: Range 0 to +8388608 at 1 kHz Max Rate, Accuracy ±1 Count Max.
- Pulse Width (T_PW): Min 200 uS, Accuracy ±50 uS ±1%.
- Duty Cycle: Range 1% to 99%, Operating Conditions 0.01 Hz to 1000 Hz with T_PW MIN = 200 uS, Accuracy ±1.5% Max.
Discrete I/O
- Digital Outputs: 2x Open Drain, 100 mA max.
- Digital Inputs: V_inHighThreshold = 2.2 V_MAX, V_inLowThreshold = 0.3 V_MIN, V_inMAX = 30 VDC.
Configuration Options
The series utilizes a modular M12 construction with specific connector configurations for process and I/O access. The overall dimensions are 22.1 mm W x 96.7 mm L (0.87" x 3.80") not including mounting tabs.
Connectors
- M12 5-Pin Female Connector: Supports Process Mode or Mixed Mode wiring configurations for Excitation Power, Ground Reference, and up to two process inputs (Process 0/1) or digital pulse/reset signals.
- M12 8-Pin Male Connector: Provides access to Discrete I/O Signals (DIO 0, DIO 1), Interrupt Signal (INTR), I2C Clock/Data (SCL/SDA), Shield Ground, and Power Supply (3.3VDD/GND).
Configuration & Ecosystem
The probe is software-configurable via SYNC software to enable integrated alarm and control functions with secure authentication. It supports deployment in wired or wireless configurations using Omega Link Smart Interfaces and Gateways.
- Smart Interfaces: Wired USB (IF-001), Wired RS485/Modbus (IF-002), Wireless Sub GHz 915 MHz (IF-006-1-NA) or 868 MHz (IF-006-1-EU).
- Gateways: Includes Wired IIoT Gateway Standard, Wireless IIoT Gateways (Standard/Pro/LTE variants), supporting Ethernet connectivity and Modbus protocols.
Accessories
The series supports various field-install connectors and cables:
- M12.5-S-M-FM: M12 5-pin Straight Plug Field install connector with screw terminals.
- M12.8-T-SPLIT: Smart Probe M12-8 pin shielded T-Splitter enabling access to I/O pins.
- Cables: Dual M12-8 connectors available in lengths of 1m (3.3'), 3m (9.8'), and 5m (16.4') with straight or right angle terminators.
Key Product Differences
The primary enumerated model is SP-014-1, described as the Omega Link Process Monitoring Smart Probe with discrete I/O. The series supports mixed-mode operation where Pin 2 and Pin 5 of the M12 5-Pin Female Connector function differently depending on configuration: in Mixed Mode, they serve as DIN 0/Pulse A and DIN 1/Reset respectively.
- Model SP-014-1 is the standard offering for this series code.
The device holds CE and UKCA approvals. The document does not specify wetted materials, sheath material, housing material, pressure rating, burst pressure, vibration or shock ratings, humidity rating, or media compatibility.
PDFs & Manuals
Software & Drivers
Accessories
cables
Smart Probe M12 8 pin sheilded T Splitt
$49.65 / each
0 In Stock
signal conditioners
Smart Probe Wireless interface 915 MHZ
$415.89 / each
0 In Stock
Show Ratings & Reviews