MAN0837-03 ADC107/207 PAGE 1 SmartMod +/-10V Analog Input Module HE359ADC107 / HE359ADC207 16-Bit Resolution 1 SPECIFICATIONS ADC107 ADC207 ADC107 ADC207 Number of Channels 4 8...
3ZV1_Instruction_Manual
Bulletin V-26 Series 3ZV1 Three-Way Zone Valves By Dwyer Specifications - Installation and Operating Instructions A B C A C B Size in (mm) in (mm) in (mm) 1/2˝ 4.57 (116) 2.48 (63)...
Bulletin 06S
Bulletin V-27 Series 3ZV2 Three-Way Detachable Zone Valves ® Specifications - Installation and Operating Instructions A C B Size A [in (mm)] B [in (mm)] C [in (mm)] 1/2˝ 4.92 (125)...
3_AAL_O_FMA 6500 (DFC) M4061-0126
TM TM User’s Guide Shop online at omega.com e-mail: info@omega.com For latest product manuals: www.omegamanual.info NORWALK, CT FMA6500 Mass Flow Controller TM omega.com info...
123_125_Instruction_Manual
Bulletin IN-47 Series 123/125 Boiler Water Level Control Specifications - Installation and Operating Instructions By Dwyer 1 NPT TYP 2 PLACES 1-1/8 [28.58] 3-9/16 [90.50] ø5-3/4 B ...
Layout 2
Bulletin V-3 Series 2700 Current to Pressure Transducer Specifications - Installation and Operating Instructions 39/64 (15.5) 1-11/16 (42.7) DIN RAIL MOUNTING OPTION 1 MOUNTING HOL...
Bulletin 06S
Bulletin F-92 Series 265ER PRECISOR® II Electro-Pneumatic Rotary Positioner Specifications - Installation and Operating Instructions 4-41/64 1-25/32 6-43/64 [117.87] [45.24] [169.4...
Layout 2
Bulletin V-5 Series 2900 Current to Pressure Transducer Specifications - Installation and Operating Instructions Ø3-1/2 (Ø88.9) 4 #10-32-UNF 1 TAPPED HOLES FOR 1/2 NPT PORT FOR (25...
Layout 2
Bulletin V-4 Series 2800 Current to Pressure Transducer Specifications - Installation and Operating Instructions MOUNTING HOLES 22 GA. WIRE LEADS #10-32 UNF-2B X 3/8 DP APPROX. 18˝...
2_5000_Instruction_Manual
Bulletin A-36 Series 2-5000 Minihelic® II Differential Pressure Gage ® Specifications - Installation and Operating Instructions LOW PRESSURE PORT Ø7/16 [11.11] HOLE IN PANEL FOR SU...
Bulletin 06S
Bulletin V-16 Series 3PBV Automated Ball Valves - 3-Way Plastic ¤ Specifications - Installation and Operating Instructions E C F PNEUMATIC DOUBLE ACTING – inches/(mm) A 1/2˝ 3/4˝ 1...
PowerPoint Presentation
Hazardous Location Analyzer Field Servicing Guide Oxygen Analyzers PST-FSG-3015-00 ProcessSensing.com 07/2024 Hazardous Location Analyzer Field Servicing Guide Oxygen Analyzers Rev...
GPR-Portable Oxygen Analyzer User Manual
GPR-Portable Oxygen Analyzers User Manual PST-UM-3005-EN-01 PST-UM-3005-EN-01 07/2024 GPR-Portables Oxygen Analyzer User Manual Issue No. Description Date Author Initials 00 New do...
GPR-x500 A Oxygen Analyzers User Manual
GPR-x500 A Oxygen Analyzers User Manual PST-UM-3019-EN-01 PST-UM-3019-EN-01 GPR-x500 A Oxygen Analyzer User Manual Issue No. Description Date Author Initials 01 Original document ...
GPR-x500 Oxygen Analyzer User Manual
GPR-x500 Oxygen Analyzers User Manual PST-UM-3004-EN-03 PST-UM-3004-EN-03 03/2024 GPR-x500 Oxygen Analyzer User Manual Issue No. Description Date Author Initials 01 Original docume...
SSS-1000
Stand Alone Carbon Monoxide Detectors Application and Installation Note Series GSTA Series SCD While many parking garage applications require a carbon monoxide transmitter SERIES S...
AI_Palm-O2D_manual-80621
Manufactured under a Quality Management System independently certified to medical device standards: MDD/93/42 EEC, Annex II ISO 13485:2003 ISO 9001:2015 Copyright © 2/18 All Rights...
626_628_Quick_Start_Guide,_CB_Option
Bulletin ® P-626-CB-QS Series 626/628-CB Industrial Pressure Transmitters QUICK START GUIDE For best accuracy, install in a location with the pressure connection downward and use s...
626_628_Quick_Start_Guide
® Bulletin E-111-A-QS Series 626 & 628 Pressure Transmitters QUICK START GUIDE Position: For best accuracy, mount with the pressure connection facing downward and use suitable ...
616W-manual
Bulletin P-616W-1 Series 616W Differential Pressure Transmitter ® Specifications - Installation and Operating Instructions 3-1/8 [79.38] Ø3/16 [4.76] MOUNTING HOLES 1-1/4 TYP 4 PLA...
616WL_Instruction_Manual
Bulletin E-43-WL Series 616WL Differential Pressure Transmitter ® Specifications - Installation and Operating Instructions 3-1/8 3/16 [4.76] [79.38] MOUNTING HOLES TYP 4 PLCS 4-17/...
9vu-instructions
INSTALLATION, OPERATING AND MAINTENANCE INSTRUCTIONS 9" VA R I - A N G LE ® LIQUID IN GLASS THERMOMETER - 9VU Warning: All liquid-in-glass thermometers should be selected consi...
A-3000
® SERIES A-3000 QUICK CONNECT PNEUMATIC FITTINGS COUPLING A SIZE MOUNTING COUPLING HOLE SIZE B B COUPLING A SIZE COUPLING SIZE Model A B Model A B Model A B A-3025-0 1.33 [33.8] 0....
A-2000
® SERIES A-2000 STAINLESS STEEL FITTING LINE Our stainless steel fittings and pipe nipples are made from 304 or 316 SS and are rated at 150 psi. A-2018 316 SS A-2020 Cross: A-2022 ...
AAFS_Instruction_Manual
Bulletin AQ-AAFS Model AAFS Adjustable Air Flow Switch ® Specifications - Installation and Operating Instructions 2.56 4.02 [65.00] 5 3.46 [102.00] 2. 6 [65.00] 4.15 2.81 [105.50] ...
AC-1403_instruction manual
DE Betriebsanleitung AC-1403 ca. ca. HINWEIS: Diese Betriebsanleitung ist Teil des Produktes. Lesen Sie die Betriebsanleitung vor der Verwendung des Produktes sorgfältig durch und...
A7_Instruction_Manual
Bulletin IN-A7 Series A7 Mini Pressure Switch Specifications - Installation and Operating Instructions By Dwyer 1-7/8 1/2 1-7/8 1-7/8 [47.4] [12.7] [47.4] [47.4] Ø1˝ 1-3/8 [Ø25.4] ...
untitled
IN-A9 12/12/07 9:35 AM Page 1 Bulletin IN-A9 Series A9 Mini Pressure Switch Specifications - Installation and Operating Instructions 1-7/64 [28.18] 1-35/64 1-57/64 [39.29] [48.02] ...
AC-1405_AC-1406_instruction manual
Product Information Brüel & Kjær Vibro Data: BKV Type: AC-1405 (Straight version) AC-1406 (Angled version) DESCRIPTION: M12 OVERMOLDED (A-CODE) SHIELDED POLYURETHANE CABLE ASS...
AI_AII3000_manual-50910
Technical Specifications Accuracy: < +2% of FS range under constant conditions Analysis: 0-100% oxygen Application: Personnel safety Area monitoring O2 deficiency in confine...
GPR-x500 Oxygen Analyzer User Manual
GPR-x500 GB Oxygen Transmitters (GP) User Manual AII-UG-2002-EN Rev0 AII-UG-2002-EN Rev0 CONFIDENTIAL GPR-x500 GB Oxygen Transmitter User Manual (GP) Revision Description Date Aut...
GPR-x500 Oxygen Analyzer User Manual
GPR-x500 Oxygen Analyzers User Manual PST-UM-3004-EN-03 PST-UM-3004-EN-03 03/2024 GPR-x500 Oxygen Analyzer User Manual Issue No. Description Date Author Initials 01 Original docume...
AI_GPR_1500AIS-LD-manual-40509
Technical Specifications * cUL or ATEX Certified for Hazardous Areas Accuracy: < 2% of FS range under constant conditions Analysis: 0-10, 0-100, 0-1000 PPM, 0-1%, 0-25% (CAL) FS...
ALTA-4G-Gateway Quick Start
TM by The Leading Enterprise Internet of Things Solution Quick Start Guide - ALTA 4G Industrial Gateway and Sensors Simple Setup 1. 4. Use the QR code to the right of the image to ...
AN24 & AN28 Annunciators Instruction Manual
Bulletin: P-AN2 AN24 & AN28 Annunciators Instruction Manual • 1/8 DIN Annunciators with NEMA 4X, IP65 Front • Switch, Transistor, and Logic Level Inputs • 4 or 8-Point Monitori...
ANE_1_Instruction_Manual
Bulletin TE-ANE-1 Model ANE-1 Differential Pressure Anemometer Specifications - Installation and Operating Instructions 1-37/64 [39.97] Ø4-23/64 [110.90] HOLES FOR 6-1/4 AIR INTAKE...
AP3_Instruction_Manual
Bulletin TE-AP3 Model AP3 Wireless Thermo-Anemometer Probe Specifications - Installation and Operating Instructions 5/16 [7.94] 15-3/8 [390.68] 6-3/64 [153.63] 1-41/64 1-5/32 [41.6...
Analog Input Rate/Totalizer Instruction Manual
Bulletin: L-APM Series APM Analog Panel Meter Instruction Manual • 1/8 DIN Digital Panel Flow Rate/Totalizers with NEMA 4X, IP65 Front • 0-20 mA, 4-20 mA, 0-5 V, 1-5 V, and ±10 V I...
Microsoft Word - LIMModbus2DW_A.doc
MPM, APM, PPM, & LTI Series Modbus® Register Tables DWYER INSTRUMENTS, INC. PO Box 373 • Michigan City IN 46360 USA Tel (800) 872-9141 • Fax (219) 872-9057 www.dwyer-inst.com M...
AP_Instruction_Manual
Bulletin O6S Series AP Diaphragm Operated Pressure Switches Specifications - Installation and Operating Instructions By Dwyer 1-1/16 Ø7/8 [22.23] [26.99] 15/16 KNOCK-OUT HOLE [23.8...
AQ_CDT_CDTR_2
Bulletin AQ-CDT/CDTR-2 Series CDT and CDTR Duct Mount Carbon Dioxide/ Temperature/Relative Humidity Transmitter ® Specifications - Installation and Operating Instructions 11-49/64˝...
AQ_CDT_CDTR_3
Bulletin AQ-CDT/CDTR-3 Series CDT and CDTR Duct Mount Carbon Dioxide/ Temperature/Relative Humidity Transmitter ® Specifications - Installation and Operating Instructions 11-49/64˝...
A_26_Instruction_Manual_(ranges_lower_than_10")
Bulletin A-26 Series MS Magnesense® Differential Pressure Transmitter ® Specifications - Installation and Operating Instructions 21/32 [16.67] 29/32 3-7/16 [87.31] 21/32 [23.02] [1...
I0000789
4-20mA OUTPUT CURRENT that requires a regulated +13.5 to 30VDC external SENSOR SERIES Phone: 1-888-967-5224 power source. Website: workaci.com Installation & Operation Inst...
CTF_Instruction_Manual
Bulletin L-CTF Model CTF Mini Tuning Fork Level Switch Specifications - Installation and Operating Instructions 1-3/16 1˝ NPT [30.00] 4-9/64 [105.00] 3-15/16 [100.00] Ø1-1/2 [38.00...
untitled
A-27-MW:A-27-MW 3/24/09 8:31 AM Page 1 Bulletin A-27-MW A-465 Space Pressure Sensor Installation and Operating Instructions Finished Parts List Installation of A1 – Wall plate the ...
untitled
E-50-700 8/1/07 9:04 AM Page 1 Bulletin E-50-700 Model A-700 Power Supply Specifications - Installation and Operating Instructions The Model A-700 economical and reliable power sup...
untitled
E-24-A 5/27/08 11:56 AM Page 1 Bulletin E-24-A No. A-709 RTD Transmitter Enclosure Specifications - Installation and Operating Instructions 2-27/32 (72.23 1/2 NPT 3-5/32 (80.12) 1-...
Accessories-KitsForAirFilterSwitches
ACCESSORIES - GAGE FLUIDS MODEL CHART Model Description Red gage fluid, .826 sp. gr. The standard fluid for use in inclined manometers, “D” type vertical manometers and all Dwyer g...
Accessories-Miscellaneous
ACCESSORIES - GAGE FLUIDS MODEL CHART Model Description Red gage fluid, .826 sp. gr. The standard fluid for use in inclined manometers, “D” type vertical manometers and all Dwyer g...
Accessories_-_Fittings_Filters
ACCESSORIES - FITTINGS AND FILTERS MODEL CHART Model Description A-323 Elbow compression fitting, brass 1/8˝ NPT to 1/4˝ metal tubing A-324 Compression fitting, brass 1/8˝ NPT to 1...
AdjustablePressureSnubbers_1
SERIES PS PRESSURE SNUBBER Dampens Surges, Protects Pressure Instrumentation C DIMENSIONS Model A B C B PS114 1/8˝ NPT 1/2˝ 1-7/64˝ PS214 1/8˝ NPT 1/2˝ 1-7/64˝ PS122 1/4˝ NPT 3/4˝ ...
Accessories_-_Gage_Fluids_1
ACCESSORIES - GAGE FLUIDS MODEL CHART Model Description Red gage fluid, .826 sp. gr. The standard fluid for use in inclined manometers, “D” type vertical manometers and all Dwyer g...
BPV_Instruction_Manual
Bulletin P-11 Series BPV Pneumatic Ball Vibrator Specifications - Installation and Operating Instructions By Dwyer IN OUT ØH A D C E B DIMENSIONS Model A B C D E H IN/OUT BPV-1 2-1...
BTO
SERIES BTO BIMETAL THERMOMETER WITH TRANSMITTER OUTPUT Bimetal Stem with 4-20 mA Output, 3˝ or 5˝ Dial Ø3-1/4 [Ø82.55] OR Ø5-1/4 [Ø133.35] 7-1/8 Ø3-1/16 3-5/16 [180.98] [Ø77.79] [8...
BT
SERIES BT BIMETAL THERMOMETER 2˝, 3˝ or 5˝ Dial, Dual Scale, ±1% Full-Scale Accuracy, External Reset 1/2 NPT STEM 1/2 NPT LENGTH STEM VIDEO O LENGTH N HEAD SIZE Back connection Adj...
untitled
A-27-M:A-27-M 7/16/10 9:37 AM Page 1 Bulletin A-27-M A-464 Magnehelic® Differential Pressure Gage Mounting Kit Installation and Operating Instructions A-464 shown with A-465 Space ...
CX_Instruction_Manual
Bulletin IN-525 Series CX Compressor Pressure Switch Specifications - Installation and Operating Instructions By Dwyer .236 Ø.250 Ø.236 Ø.250 [Ø6.00] OR [Ø6.35] [Ø6.00]OR [Ø6.35] 3...
Layout 2
586_Layout 2 7/5/12 10:27 AM Page 586 ACCESSORIES MODELS Pumps A-350, Aspirator Bulb. Used as pressure source in calibration and leakage tests, to draw gas sample into CO2 Indicato...
A04643; ClipX
Operating Manual | Bedienungsanleitung English Deutsch ClipX Hottinger Baldwin Messtechnik GmbH Im Tiefen See 45 64293 Darmstadt Tel. +49 6151 803-0 Fax +49 6151 803-9100 i...
BTL
® SERIES BTL SIDE READING BIMETAL THERMOMETERS 1-11/16 [42.85] 5/16 6-3/16 [157.15] [7.94] 13/16 [20.64] Horizontally Mounts to Tank 1/2-14 NPT Ø2.750 Ø3 [Ø69.85] [Ø76.2] Ø1/4 13/1...
Layout 1
237_Layout 1 7/8/14 11:51 AM Page 237 Series BTPM Panel Mount Bimetal Stem Thermometer Front Flange with Back Connection for Easy Mounting 3-21/64 [84.53] 1/4 NPT Ø1/4 [Ø6.35] 2-1/...
Layout 1
241_Layout 1 7/8/14 11:52 AM Page 241 Series DRFT Digital Solar-Powered Thermometer LCD Display, Remote Probe, Compact Size 5/8 [15.24] 4-1/2 [114.30] 1-1/8 [28.56] DWYER INSTRUMEN...
M5290_0613.indd
User’s Guide Shop on line at www.omega.com e-mail: info@omega.com iSeries info: www.omega.com/specs/iseries omegamanual.info Temperature/Process Limit Controller CNi8-AL/CNi16-...
Bulletin 06S
Bulletin G-63 Series DPMA-4 Adjustable LCD Digital Panel Meters Specifications - Installation and Operating Instructions P Models V A 3-25/32 KW 1-1/8 PF [96] [28.5] 15/32 [12] °F ...
CLS2_Instruction_Manual
Bulletin L-26 Series CLS2 Capacitive Level Switch Specifications - Installation and Operating Instructions 4-3/16 [106.36] ø3/8 [ø9.53] 4-35/64 [115.49] 23-1/2 3-19/32 [596.90] 19 ...
CDWP_Instruction_Manual_(2000,_5000PPM)
Bulletin AQ-CDWP-2 Series CDWP Carbon Dioxide Transmitter ® Specifications - Installation and Operating Instructions (OPTIONAL 4-11/32 SUSPENSION [110.32] Ø1/4 [6.35] BRACKET) 11/1...
CDWP_Instruction_Manual_(10000PPM)
Bulletin AQ-CDWP-3 Series CDWP Carbon Dioxide Transmitter ® Specifications - Installation and Operating Instructions (OPTIONAL 4-11/32 SUSPENSION [110.32] Ø1/4 [6.35] BRACKET) 11/1...
179685
MAINTENANCE/REPAIR Important Points! Continuous Level Transmitters Regular maintenance of the total system is recommended to assure sustained optimum performance. These devices are...
CLWTC-1000 Instruction Manual
CLWTC-1000 Instruction Manual Advanced Thermal Solutions, Inc. 89 Access Road #27, Norwood, MA 02062, USA Tel: 781-769-2800 Fax: 781-769-9979 email: ats-hq@qats.com Website: w...
CMT200_Instruction_Manual
Bulletin AQ-CMT200 Model CMT200 Carbon Monoxide Transmitter ® Specifications - Installation and Operating Instructions 3-9/64 [79.781] Ø1-5/64 [27.317] 1-37/64 [39.891] 2-21/64 1-3...
CN400-Series_manual
TM User’s Guide Shop online at omega.com e-mail: info@omega.com For latest product manuals: www.omegamanual.info CN400 Series Controllers omega.com info@omega.com Servicing...
CND3-Series_Manual
User’s Guide Shop online at omega.com e-mail: info@omega.com For latest product manuals: www.omegamanual.info CND3 Series Temperature Controller omega.com info@omega.com Se...
Bulletin E-90-DL7
Bulletin E-90-DL7 6/22/05 3:52 PM Page 1 Bulletin E-90-DL7 Series DL7 Differential Pressure Logger Specifications - Installation and Operating Instructions INPUT JACK FOR INTERFACE...
untitled
L-44 10/31/07 11:22 AM Page 1 Bulletin L-44 Series DLD Dual Channel Leak Detection Relay Specifications - Installation and Operating Instructions The Series DLD is a specialized co...
DLI2_Manual.indd
DLI2 Data Logger Manual P.O. Box 373 l 102 Indiana Hwy. 212, Michigan City, IN 46361 USA Phone: 219.879.8000 l Fax: 219.872.9057 www.dwyer-inst.com l info@dwyer-inst.com Table ...
Microsoft Word - Dwyer_Manual_V2.06
! " #$ %& ' ( ! ) *+ , + -.('( / ) * (., + -. 0 12 ) 3 # - 2 4 5) ! )66 # - 2 1 | P a g e Table of Contents Introduction .................................
DLI_DLI_H
DLI-H Data Logger Manual P.O. Box 373 l 102 Indiana Hwy. 212, Michigan City, IN 46361 USA Phone: 219.879.8000 l Fax: 219.872.9057 www.dwyer-inst.com l info@dwyer-inst.com Table...
DLI-P_Manual.indd
DLI-P Data Logger Manual P.O. Box 373 l 102 Indiana Hwy. 212, Michigan City, IN 46361 USA Phone: 219.879.8000 l Fax: 219.872.9057 www.dwyer-inst.com l info@dwyer-inst.com Table...
DLI-R_Manual.indd
DLI-R Data Logger Manual P.O. Box 373 l 102 Indiana Hwy. 212, Michigan City, IN 46361 USA Phone: 219.879.8000 l Fax: 219.872.9057 www.dwyer-inst.com l info@dwyer-inst.com Table...
Microsoft Word - Dwyer_Manual_V2.06
! " #$ %& ' ( ! ) *+ , + -.('( / ) * (., + -. 0 12 ) 3 # - 2 4 5) ! )66 # - 2 1 | P a g e Table of Contents Introduction .................................
DL_USB_RT
Bulletin DL-USB-RT Model DW-USB-RT Real-time USB Data Logger ® Specifications - Installation and Operating Instructions 2-61/64 [75.18] 2-1/2 [63.50] 3/4 [19.05] 3/8 [9.52] BLUE LE...
E-90-DLX
E-90-DLX 1/27/06 1:52 PM Page 1 Bulletin E-90-DLX Series DL Data Logger Specifications - Installation and Operating Instructions SECURITY EYELET MAGNETIC STRIP 2.956 TEMPERATURE .6...
DPS20_manual_en
TM User’s Guide Shop online at omega.com e-mail: info@omega.com For latest product manuals: www.omegamanual.info DPS20 Series Panel Meter for Load cell signals 6-Digit, 1⁄8 DIN...
DR-I4F Quick Start Guide
QUICK START GUIDE 4. CONNECTIONS 6. PRECONFIGURED CONFIGURATION CODES TM Power from 18 to 265 Vac/dc isolated Table 3 | Predefined configuration Table 3 | Predefined configuration ...
H-12rev.qxd
Bulletin PC-DPMF Series DPMF Flush Mount LCD Digital Panel Meter Installation and Operating Instructions 2-3/8 [59.94] 1-1/8 1 [29.03] [25.40] 2-3/16 Ø1/8 1/4 [55.56] [Ø2.5] [6.35]...
SSS-1000
Bulletin F-DTFA Series DTFA Variable-Area Flowmeter for Gases Specifications - Installation and Operating Instructions 1 3-19/32 [25.40] [91.44] 3/4 [19.05] Ø2-59/64 [74.17] 2 [50....
Model PHO-1
Bulletin G-61 Series DPML-4 LCD Digital Panel Meters Specifications - Installation and Operating Instructions P Models V A KW 2-35/64 PF 1/8 [64.5] [3] °F °C 1-9/64 63/64 PSI [29] ...
REVISEDBulletin F-50
REVISEDBulletin F-50 7/8/04 8:04 AM Page 1 Bulletin F-50 Series DS-300 Flow Sensors Installation and Operating Instructions Flow Calculations 1-15/16 (49.21) 1-5/8 (41.27) TYP LP 1...
Model PHO-1
Bulletin E-90-DPMW Series DPMW LCD Digital Panel Meters Specifications - Installation and Operating Instructions P Models 1/8 V A [3] KW 17/64 2-3/8 1/8 PF [6.9] [60.5] [3] °F °C 6...
TDS0129_Platinum Sensor User Manual
Technical data sheet TDS129 PLATINUM IR SENSOR USER MANUAL Certified (Ex’d) Low Power Certified (Ex’d) Non-Certified Low Power Non-Certified SIL1 Certified (Ex’d) Low Power SIL1 Ce...
B&K_Datasheet_DT-12.ai
The next generation of shaft monitoring The world’s first fully integrated, loop-powered displacement transmitter series DT-12x. The DT-12x series of integrated displacement transm...
F6_F7Vertical_F7_Instruction_Manual
Bulletin E-75 Series F7 Liquid Level Switches Specifications - Installation and Operating Instructions EXTERNALLY WELDED FLANGE 2 MAX 13/16 MIN PIPE ELBOW FITTING 1-7/3 [20.6] CENT...
202518
Externally-Mounted Bottle-Style Level Switches Model F7-EB To Install . . . Locate and prepare entrances in tank side so that level switch unit will be in vertical position with wi...
Layout 2
324_Layout 2 7/23/12 3:31 PM Page 324 Model F7-MLK Multi-Level Switch Kit One or Two Station Level Switch, Vertically Mount TUBE FLOAT TUBE FLOAT TUBE WITCH AND SWITCH TUBE END 2 N...
Bulletin 06S
Bulletin E-75 Series F7 Liquid Level Switches Specifications - Installation and Operating Instructions PIPE EXTERNALLY ELBOW WELDED FLANGE 13/16 MIN COUPLING FITTING [20.6] CENTERL...
Bulletin 06S
Bulletin L-FCLS Model FCLS Flush Capacitance Level Switch Specifications - Installation and Operating Instructions 4-3/8 [110.95] 4-9/32 [108.83] 7-11/32 [186.34] 5-57/64 [149.43] ...
...
[+]