Skip to search Skip to main content Skip to navigation

Netherlands 07077 03815 | Intl +31 (0) 7077 03815 | Welcome to our new website, found an issue or bug? Please report it here

We noticed you are in , please visit your local site by clicking the below link for regional offers and support.

Model-9671

Multifunction Vane Thermo-Anemometer: Air Velocity, Temp, Humidity, BTU

Model-9671
From £ 316.63
Multifunction Vane Thermo-Anemometer: Air Velocity, Temp, Humidity, BTU Model-9671 Model-9671
loading all models
Product Overview
  • Additional Features 1 Hard Carrying Case
  • Air Velocity Accuracy ± 5%
  • Air Velocity Accuracy Note ± 5% of Reading or Last Significant Digit (whichever is greater)
  • Air Velocity, Min 118 FPM
  • Air Velocity Resolution 0.1 ft/min
  • Air Velocity Response Time 1 Sec
  • Air Volume 0 to 99999 CFM
  • Air Volume Accuracy ± 5%
  • Air Volume Accuracy Note ± 5% of reading or last significant digit (whichever is greater)
  • Air Volume Resolution 0.1 or 1
  • Air Volume Response Time 1 sec
  • Battery life 100 hr
  • Battery Size and Type Alkaline AA
  • Baud Rate 9600
  • Display Measuring Units °C, °F, ft/min, k/h, knot, m/s, mph
  • Display Size 46 mm (1.8 in)
  • Display Type LCD
  • Process Temperature, Max 140 °F
  • Process Temperature, Min -4 °F
  • Relative Humidity 0 to 100%
  • Relative Humidity Accuracy ± 3% RH
  • Relative Humidity Accuracy Note ± 3% @ 25°C from 10 to 90% RH. Outside this range: ± 5%
  • Relative Humidity Resolution 0.001
  • Relative Humidity Response Time 60 sec
  • Series ID Model-9671
  • Supply Power Note (4) AAA Alkaline Batteries, Included, User Replaceable
  • Supply Power Type Battery
  • Temperature Accuracy ±1 °F
  • Temperature Resolution 0.1°C, 0.1°F
  • Temperature Response Time 60 sec
  • Vane Diameter 3 in
  • Weight 6 oz
  • Wet Bulb Resolution 0.1°F/°C
  • Wet Bulb Temperature, Max 158 °F
  • Wet Bulb Temperature, Min -7.6 °F

Supported Applications

The Dwyer Model 9671 Multifunction Vane Thermo-Anemometer is a handheld datalogger designed for air flow measurement. The series measures velocity, humidity, temperature, wet bulb, and air volume parameters to support HVAC testing and airflow analysis.

Operating Conditions & Performance

The Model 9671 operates across specific ranges with defined accuracy and response times:

  • Air Velocity: Range of 118 to 6299 ft/min (0.6 to 32 m/s) with an accuracy of ±5% of reading or last significant digit (whichever is greater). Resolution is 0.1 ft/min (0.1 m/s), and response time is 1 second.
  • Air Volume: Range of 0 to 99999 CFM or m³/s with an accuracy of ±5% of reading or last significant digit (whichever is greater). Resolution varies by range: 0.1 for values 0 to 9999.9, and 1 for values 10000 to 99999. Response time is 1 second.
  • Temperature: Range of -4 to 140°F (-20 to 60°C) with an accuracy of ±1°F (±0.6°C). Resolution is 0.1°F/°C, and response time is 60 seconds.
  • Relative Humidity: Range of 0 to 100% with an accuracy of ±3% @ 25°C from 10 to 90% RH; ±5% outside this range. Resolution is 0.10%, and response time is 60 seconds.
  • Wet Bulb: Range of -7.6 to 158°F (-22 to 70°C) with a resolution of 0.1°F/°C.

The device features a vane diameter of 3" (77 mm), weighs 6 oz (170 g), and includes CE approval. Power is supplied by four AAA alkaline batteries, providing approximately 100 hours of battery life.

Configuration Options

The Model 9671 series supports multiple measurement modes to accommodate different data collection needs:

  • Single Point Measurement: Captures a single reading with no memory storage.
  • Multiple Point Measurement: Allows for editable file names and stores up to 99 points. Users measure and store by pressing specified keys.
  • Automatic Logging (Datalogging): Supports programmable datalogging with a capacity of 2400 memory points. Files are named with the default date and time. The system automatically measures and stores data according to pre-set parameters, including Begin-Date, Start-Time, End-Date, Suspend-time, and sample rate.

Communication is handled via an RS-232 interface (9600 bps, 8 data bits, no parity) using a PS/2 PLUG connector. The unit includes a display measuring 1 x 1.8" (26 x 45 mm). Accessories available for the series include replacement probes: A-551 (Replacement Probe with Vane) and A-VT300-P (Replacement Probe with Miniature Vane).

Key Product Differences

The Model 9671 is offered as a complete kit including the meter, hard carrying case, batteries, software CD, RS-232 cable, and instruction manual. The series supports interchangeable probes to adapt to different measurement scenarios: the standard vane probe (A-551) or the miniature vane probe (A-VT300-P). While BTU calculation is listed as a function in the product overview, specific technical specifications such as range, accuracy, and resolution for BTU are not provided in the documentation.