Need assistance? Call us: 1-800-663-4209
UMR14-Series
Medium Range Ultrasonic Level/Distance Transmitter-Switch
Models In Stock
- Type 316 stainless steel housing (except PVC model)
- Ruggedized piezoelectric ultrasonic transducer
- Hardened & protected solid state electronics
- UV resistant, potted-in, PUR-jacketed cable
UMR14-Series
From
€
768,38
Models In Stock
Product Overview
- Accuracy ± 0.5 %
- Cable Length 6.5 ft
- Electrical Output 2 Outputs (4-20 mA,0-10 V)
- Enclosure Ratings IP68, NEMA Type 4X
- Loop Resistance 450 Ω max @ > 15 Vdc, 250 Ω max @ 10 Vdc
- Measuring Range, Max 14 ft
- Measuring Range, Min 4 ft
- Media Compatibility Any, Clean dry air / inert gas, Clean process / cooling water, Corrosive chemicals / acids / bases, Fuel gases, HVAC / room air, Hydraulic fluids, Inert / non-reactive gases, Liquids, Oils / lubricants, Organic solvents, Steam, Nitrogen, Non-corrosive Dry Gasses, Oil, Oxygen, Solvents, Water, Water-based fluids
- Memory Non - Volatile
- Operating Humidity 0 to 100% RH
- Operating Pressure, Max 50 psi
- Operating Temperature, Max 70 °C
- Operating Temperature, Min -40 °C
- Output Signal Current, Voltage
- Resolution 0.0034 in
- Series ID UMR14-Series
- Transducer frequency 120 kHz
- Ultrasonic Beam Width 12 ° at -3db
Supported Applications
The Omega UMR14 Series is a medium-range ultrasonic level/distance transmitter-switch designed for non-contact distance measurement in tough industrial environments. As part of the broader U-Series family, these sensors measure liquid or solid levels and proximity without physical contact with the target material.
- Ultrasonic non-contact distance measurement (level, proximity, dimensioning)
Operating Conditions & Performance
The UMR14 model provides a maximum range of 14 ft. (4.3 m) with a minimum deadband of 4 in. (10.2 cm). The optimum operating range is specified as 4 in. (10.2 cm) to 10 ft (3m), particularly for small targets, dry materials, or hot conditions.
- Accuracy: Better than 0.5% of target distance in stable, homogeneous air environment; affected by temperature gradients, target echo strength, speed of sound in air or vapors
- Repeatability: Greater of +/-0.03 in. (0.76 mm) or 0.25% of target distance in stable environment
- Ambient Temperature: -40 to +158 F (-40 to +70 C), temperature compensated by internal sensor or external Reference Target
- Humidity: 0-100% (avoid heavy condensation)
- Ingress Protection: IP-68, NEMA-4X
- Measurement Rate: Default 50 msec (20 Hz); adjustable from 5 msec to 2.8 hours; faster rates limit max target distance and are affected by filter selections
Analog Resolution & Output Load
The analog output resolution provides 4100 steps over 0-10 VDC and 3279 steps over 0-20 mA, scaled between user-set distance endpoints. Serial data resolution is 0.0034 in. (0.086 mm). Current loop load resistance limits are 450 Ohm max @ >15VDC or 250 Ohm max @ 10 VDC; maximum loop resistance is 500 Ohm @ 24 VDC sensor input voltage.
Configuration Options
The UMR14 Series supports multiple simultaneous outputs configurable via OmegaVIEW PC software or a rear TEACH pushbutton (except on serial-only models). The series offers full-featured configurations with two selectable outputs, including solid-state switches and analog signals.
Housing & Mounting
- Material: 316 Stainless steel housing for UMR14 sensors
- Mount Options: m30x1.5 metric thread or 1-in NPT thread (part number suffixes -30MM and -1NPT)
- Dimensions: 1.2 in. (30.4mm) dia x 4.064 in. (103mm) length
Electrical & Communication Interfaces
- Power Supply: 10-30 VDC @ 55 mA max; typical 45 mA @ 24VDC input +I/O; serial-only models draw typical 35 mA @ 24VDC
- Analog Outputs (OmegaVIEW selectable):
- 0-10 VDC voltage (or custom, OmegaVIEW configured), 10 mA max; requires min 15 VDC input for full 10 VDC output
- 4-20 mA sourcing current loop (or OmegaVIEW configured 0-20 mA custom)
- Solid State Switches: 150 mA, PNP (@ input voltage) or NPN (external 40 VDC max.), configurable as setpoint mode or window mode
- Serial Interface Options:
- RS-232 (PC COM port)
- RS-485: 2-wire multi-drop addressable (addresses 1-247), Baud rates 9600 - 115200, none or even parity, 8 bits, one stop bit
- Cabling: Embedded 6.5-ft (2m) shielded PUR cable with tinned ends; 6-wire for full outputs, 4-wire for serial-only models. M12 connector on 18 in. cable available.
Configuration & Accessories
Sensors are configured using OmegaVIEW software (free download) or the TEACH pushbutton. PC interface kits include KIT-USB-232 and KIT-USB-485 with converter, terminal block, power supply, and data cable. Mounting accessories include MB30-SS90 stainless steel 90-degree mounting bracket and NUT30-SS316 one pair (SS316) stainless steel m30x1.5 nuts.
Key Product Differences
The UMR14 Series is distinguished within the Omega U-Series by its specific range envelope of 14 ft. (4.3 m). While other series members offer different ranges—USR03 at 3 ft, ULR30 at 30 ft, and UXLR50 at 50 ft—the UMR14 maintains a transducer frequency of 120 kHz with a nominal beam width of ~12 degrees @ -3 dB.
- Model Number Structure: [PRODUCT]-[MOUNT]-[SERIAL INTERFACE]. For example, UMR14-1NPT-232 indicates the 14 ft range sensor with 1-in NPT thread and RS-232 interface; UMR14-30MM-485 indicates m30x1.5 metric mount with RS-485.
- Output Configuration: Full-output models provide two outputs selectable via OmegaVIEW (voltage, current loop, or switches). Serial-only versions are available but lack analog/switch outputs on the embedded cable wires designated for those functions.
Note: Output selection is made before connecting to equipment and is not affected by a TEACH 17 reset. A power supply voltage between 15-30 VDC is recommended; target sensitivity and maximum voltage output value are reduced at voltages below 15 VDC.