Skip to search Skip to main content Skip to navigation

Need assistance? Call us: 1-800-663-4209

We noticed you are in , please visit your local site by clicking the below link for regional offers and support.

UMR14-Series

Medium Range Ultrasonic Level/Distance Transmitter-Switch

Models In Stock
  • Type 316 stainless steel housing (except PVC model)
  • Ruggedized piezoelectric ultrasonic transducer
  • Hardened & protected solid state electronics
  • UV resistant, potted-in, PUR-jacketed cable
UMR14-Series
From 768,38 
Models In Stock
Medium Range Ultrasonic Level/Distance Transmitter-Switch UMR14-Series UMR14-Series
loading all models
Product Overview
  • Accuracy ± 0.5 %
  • Cable Length 6.5 ft
  • Electrical Output 2 Outputs (4-20 mA,0-10 V)
  • Enclosure Ratings IP68, NEMA Type 4X
  • Loop Resistance 450 Ω max @ > 15 Vdc, 250 Ω max @ 10 Vdc
  • Measuring Range, Max 14 ft
  • Measuring Range, Min 4 ft
  • Media Compatibility Any, Clean dry air / inert gas, Clean process / cooling water, Corrosive chemicals / acids / bases, Fuel gases, HVAC / room air, Hydraulic fluids, Inert / non-reactive gases, Liquids, Oils / lubricants, Organic solvents, Steam, Nitrogen, Non-corrosive Dry Gasses, Oil, Oxygen, Solvents, Water, Water-based fluids
  • Memory Non - Volatile
  • Operating Humidity 0 to 100% RH
  • Operating Pressure, Max 50 psi
  • Operating Temperature, Max 70 °C
  • Operating Temperature, Min -40 °C
  • Output Signal Current, Voltage
  • Resolution 0.0034 in
  • Series ID UMR14-Series
  • Transducer frequency 120 kHz
  • Ultrasonic Beam Width 12 ° at -3db

Supported Applications

The Omega UMR14 Series is a medium-range ultrasonic level/distance transmitter-switch designed for non-contact distance measurement in tough industrial environments. As part of the broader U-Series family, these sensors measure liquid or solid levels and proximity without physical contact with the target material.

  • Ultrasonic non-contact distance measurement (level, proximity, dimensioning)

Operating Conditions & Performance

The UMR14 model provides a maximum range of 14 ft. (4.3 m) with a minimum deadband of 4 in. (10.2 cm). The optimum operating range is specified as 4 in. (10.2 cm) to 10 ft (3m), particularly for small targets, dry materials, or hot conditions.

  • Accuracy: Better than 0.5% of target distance in stable, homogeneous air environment; affected by temperature gradients, target echo strength, speed of sound in air or vapors
  • Repeatability: Greater of +/-0.03 in. (0.76 mm) or 0.25% of target distance in stable environment
  • Ambient Temperature: -40 to +158 F (-40 to +70 C), temperature compensated by internal sensor or external Reference Target
  • Humidity: 0-100% (avoid heavy condensation)
  • Ingress Protection: IP-68, NEMA-4X
  • Measurement Rate: Default 50 msec (20 Hz); adjustable from 5 msec to 2.8 hours; faster rates limit max target distance and are affected by filter selections

Analog Resolution & Output Load

The analog output resolution provides 4100 steps over 0-10 VDC and 3279 steps over 0-20 mA, scaled between user-set distance endpoints. Serial data resolution is 0.0034 in. (0.086 mm). Current loop load resistance limits are 450 Ohm max @ >15VDC or 250 Ohm max @ 10 VDC; maximum loop resistance is 500 Ohm @ 24 VDC sensor input voltage.

Configuration Options

The UMR14 Series supports multiple simultaneous outputs configurable via OmegaVIEW PC software or a rear TEACH pushbutton (except on serial-only models). The series offers full-featured configurations with two selectable outputs, including solid-state switches and analog signals.

Housing & Mounting

  • Material: 316 Stainless steel housing for UMR14 sensors
  • Mount Options: m30x1.5 metric thread or 1-in NPT thread (part number suffixes -30MM and -1NPT)
  • Dimensions: 1.2 in. (30.4mm) dia x 4.064 in. (103mm) length

Electrical & Communication Interfaces

  • Power Supply: 10-30 VDC @ 55 mA max; typical 45 mA @ 24VDC input +I/O; serial-only models draw typical 35 mA @ 24VDC
  • Analog Outputs (OmegaVIEW selectable):
    • 0-10 VDC voltage (or custom, OmegaVIEW configured), 10 mA max; requires min 15 VDC input for full 10 VDC output
    • 4-20 mA sourcing current loop (or OmegaVIEW configured 0-20 mA custom)
  • Solid State Switches: 150 mA, PNP (@ input voltage) or NPN (external 40 VDC max.), configurable as setpoint mode or window mode
  • Serial Interface Options:
    • RS-232 (PC COM port)
    • RS-485: 2-wire multi-drop addressable (addresses 1-247), Baud rates 9600 - 115200, none or even parity, 8 bits, one stop bit
  • Cabling: Embedded 6.5-ft (2m) shielded PUR cable with tinned ends; 6-wire for full outputs, 4-wire for serial-only models. M12 connector on 18 in. cable available.

Configuration & Accessories

Sensors are configured using OmegaVIEW software (free download) or the TEACH pushbutton. PC interface kits include KIT-USB-232 and KIT-USB-485 with converter, terminal block, power supply, and data cable. Mounting accessories include MB30-SS90 stainless steel 90-degree mounting bracket and NUT30-SS316 one pair (SS316) stainless steel m30x1.5 nuts.

Key Product Differences

The UMR14 Series is distinguished within the Omega U-Series by its specific range envelope of 14 ft. (4.3 m). While other series members offer different ranges—USR03 at 3 ft, ULR30 at 30 ft, and UXLR50 at 50 ft—the UMR14 maintains a transducer frequency of 120 kHz with a nominal beam width of ~12 degrees @ -3 dB.

  • Model Number Structure: [PRODUCT]-[MOUNT]-[SERIAL INTERFACE]. For example, UMR14-1NPT-232 indicates the 14 ft range sensor with 1-in NPT thread and RS-232 interface; UMR14-30MM-485 indicates m30x1.5 metric mount with RS-485.
  • Output Configuration: Full-output models provide two outputs selectable via OmegaVIEW (voltage, current loop, or switches). Serial-only versions are available but lack analog/switch outputs on the embedded cable wires designated for those functions.

Note: Output selection is made before connecting to equipment and is not affected by a TEACH 17 reset. A power supply voltage between 15-30 VDC is recommended; target sensitivity and maximum voltage output value are reduced at voltages below 15 VDC.

Accessories

accessoires

USB-Setup-Kit (für RS-232-Sensoren)
147,91 € / stück
0 In Stock
USB-Setup-Kit (für RS-485-Sensoren)
151,17 € / stück
0 In Stock

installation hardware

Halterung, 90 Grad (nur für ToughSonic 3 & 14, 30 mm)
49,33 € / stück
0 In Stock
Montagemuttern, Menge 2, (nur für ToughSonic 3 & 14, 30 mm)
16,47 € / stück
0 In Stock
en-US
it_IT
Save Configuration