United Kingdom 0800 488 488 | Intl +44 (0) 161 777 6611 | Welcome to our new website, found an issue or bug? Please report it here
OM-CP-HITEMP140X2-TD-Series
High Temperature Dual Channel Data Loggers
Registratori di dati a doppio canale ad alta temperatura- OM-CP-HITEMP140X2-TD-FP-72 Has One Rigid Ambient Probe and One Flexible Probe
- OM-CP-HITEMP140X2-TD-PT-1 and OM-CP-HITEMP140X2-TD-PT-5 Have One Rigid Ambient Probe and One Stainless Steel Bendable Probe
- Rigid Ambient Probe Measures from -200 to 260°C (-328 to 500°F)
- Flexible Probe Measures from -60 to 260°C (-76 to 500°F)
OM-CP-HITEMP140X2-TD-Series
From
€
1.311,41
Product Overview
- Battery life up to 1 yr
- Battery Size and Type 3.6V Li-ion
- Calibration Digital calibration through software
- Data Interface USB
- Data Interface Note OM-CP-IFC400 USB docking station or OM-CP-IFC406 multiplexer interface required; 125,000 baud
- Diameter 24.6 mm
- Enclosure Ratings IP68
- Form factor Handheld
- Height 48 mm
- Materials, Wetted 316 Stainless Steel, PEEK, Polyurethane
- Measurement Type Temperature
- Memory 32767
- Memory Note 32,767 readings
- Number of Measurements 2
- Operating Temperature, Max 140 °C
- Operating Temperature, Min -40 °C
- Probe Diameter 2 in
- Probe Length 0.125 in
- Readings in Trigger Settings Mode 16,383 readings
- Real Time Recording May be used with PC to monitor and record data in real time
- Relative Humidity Accuracy ± 3% RH
- Relative Humidity, Max 1
- Relative Humidity, Min 0%
- Samples,Max 33000
- Sampling Rate 1 Hz (1 update/second)
- Sampling Rate Note 1 reading every second to 1 every 24 hours.
- Series ID OM-CP-HITEMP140X2-TD-Series
- Software Compatibility Windows XP SP3/Vista/7 and 8 (32- and 64-bit)
- Start Modes Adjustable Delay Start, Immediate Start
- Stop Modes Adjustable Delay Stop, Manual Through Software
- Supply Power Type Battery
- Temperature Measurement, Max 260 °C
- Temperature Measurement, Min -60 °C
- Temperature Resolution 0.01 °C
- Temperature Sensor Type RTD
- Time Accuracy 1 minute/month @ 25°C (77°F)
- Weight 100 g
La serie OM-CP-HITEMP140X2-TD di registratori di dati a doppia sonda offre estrema flessibilità per applicazioni di monitoraggio ad alta temperatura. Questi modelli presentano tutti una sonda rigida a diametro di transizione di 5,1 cm (2') per misurare la temperatura ambiente, combinata con una seconda sonda pieghevole o flessibile opzionale. La sonda rigida per ambiente è realizzata in acciaio inossidabile, offre un tempo di risposta rapido ed è adatta agli ambienti più severi.
I modelli OM-CP-HITEMP140X2-TD-PT-1 e OM-CP-HITEMP140X2-TD-PT-5 combinano la sonda rigida ambiente da 5,1 cm (2') con una sonda pieghevole in acciaio inossidabile da 61 cm (24'), dotata di una guaina sonda da 2,5 cm (1') o 12,7 cm (5') all'estremità. Le opzioni di sonda PT in acciaio inossidabile consentono di mantenere la forma una volta piegate e offrono un intervallo di misura estremamente elevato fino a 350°C.
Il modello OM-CP-HITEMP140X2-TD-FP-72 combina la sonda rigida ambiente da 5,1 cm (2') con una sonda RTD flessibile leggera da 183 cm (72'), progettata per una facile collocazione. L'opzione di sonda flessibile è molto malleabile e rivestita con isolamento in PFA, ideale per l'uso all'interno di piccole fiale e provette. Questo tipo di sonda ha un diametro ridotto, alta precisione ed è ideale per sterilizzazione a vapore e liofilizzazione. La sonda flessibile è anche compatibile con l'accessorio sonda OM-CP-MICRODISC, utilizzato per il monitoraggio della temperatura superficiale di scaffalature e altro.
L'intervallo di temperatura operativa per il corpo del registratore è da -40 a 140°C (-40 a 284°F). Grazie alla registrazione simultanea della temperatura ambiente e remota, la serie OM-CP-HITEMP140X2-TD è ideale per l'uso nella mappatura di autoclavi, applicazioni di lavorazione alimentare e molto altro.
La serie OM-CP-HITEMP140X2-TD utilizza l'ultimo software disponibile. Ciò consente un semplice avvio, arresto e scaricamento dei dati raccolti. I dispositivi possono memorizzare fino a 32.700 letture con data e ora in memoria solida non volatile. Una volta scaricate nel software, le letture possono essere visualizzate in forma grafica, tabellare e riepilogativa per una facile analisi, oltre alla possibilità di esportarle in Excel per ulteriori calcoli.
L'OM-CP-MULTIMOUNT-Z è un supporto versatile per l'uso con la serie OM-CP-HITEMP140 di registratori di dati. Può essere utilizzato per stabilizzare un registratore all'interno di un autoclave o fissato a una superficie piana per creare una base ancorata. Realizzato in acciaio inossidabile 316, l'OM-CP-MULTIMOUNT-Z è in grado di resistere a temperature fino a 150°C (302°F), rendendolo ideale per processi di sterilizzazione in autoclave.
SPECIFICHE
TEMPERATURA
Sensore di temperatura:
OM-CP-HITEMP140X2-TD-PT-1,
OM-CP-HITEMP140X2-TD-PT-5: Sonda RTD rigida ambiente con sonda RTD pieghevole in acciaio inossidabile
OM-CP-HITEMP140X2-TD-FP-72: Sonda RTD rigida ambiente con sonda RTD flessibile isolata in PFA
Intervallo di misura della sonda:
Sonda rigida ambiente: -200 a 260°C (-328 a 500°F)
Sonda pieghevole in acciaio inossidabile: -200 a 350°C (-328 a 662°F)
Sonda flessibile: -60 a 260°C (-76 a 500°F)
Risoluzione della temperatura: 0,01°C (0,02°F)
Precisione calibrata: ± 0,1°C (± 0,18°F)
GENERALE
Frequenza di lettura: 1 lettura al secondo fino a 1 lettura ogni 24 ore
Memoria: 32.767 letture
Modalità di avvio:
• Avvio immediato programmabile via software
• Avvio ritardato fino a 18 mesi in anticipo
Modalità di arresto: Manuale o temporizzato (data e ora specifiche)
Registrazione in tempo reale: Può essere usato con PC per monitorare e registrare dati in tempo reale
Protezione con password: È possibile programmare una password opzionale nel dispositivo per limitare l'accesso alle opzioni di configurazione. I dati possono essere letti senza password
Numero di letture in modalità impostazioni trigger: 16.383 letture
Impostazioni trigger: Possono essere impostati limiti alti e bassi. Una volta che i dati raggiungono o superano i limiti impostati, il dispositivo registra in memoria. Possono essere programmati trigger di avvio e arresto a due livelli. Gli utenti possono specificare il numero di letture da effettuare dopo l'attivazione del trigger. (Attivazione solo sul canale 1)
Memoria circolare: Sì (selezionabile via software)
Tipo di batteria: Batteria al litio ad alta temperatura da 3,6V inclusa; sostituibile dall'utente
Durata della batteria: 1 anno tipico [frequenza di lettura 1 minuto a 25°C (77°F)]
Calibrazione: Calibrazione digitale tramite software
Data calibrazione: Registrata automaticamente nel dispositivo
Formato dati: Data e ora con timbro °C, °F, °R, K
Precisione temporale: 1 minuto/mese a 25°C (77°F)
Interfaccia computer: Richiede stazione docking USB OM-CP-IFC400 o interfaccia multiplexer OM-CP-IFC406; 125.000 baud
Software: Windows XP SP3/Vista/7 e 8 (32-bit e 64-bit)
Ambiente operativo: -40 a 140°C (-40 a 284°F), 0 a 100% UR, 0,002 a 100 psia
Classe di protezione: IP68
Dimensioni (corpo): 48 H x 24,6 mm diam. (1,89 x 0,97')
Dimensioni (sonda):
Sonda rigida ambiente (tutti i modelli): 51 L x 3,2 mm diam. (4,8 mm diam. di transizione);
2,0 x 0,125' (0,188' diam. di transizione)
OM-CP-HITEMP140X2-TD-PT-1
Sonda pieghevole in acciaio inossidabile:
Punta sonda: 42 L x 3,2 mm diam. (1,7 x 0,125')
Parte pieghevole: 559 L x 1,6 mm diam. (22 x 0,062')
OM-CP-HITEMP140X2-TD-PT-5
Sonda pieghevole in acciaio inossidabile:
Punta sonda: 121 L x 3,2 mm diam. (4,8 x 0,125') con manico 25 L x 4,8 mm diam. (1 x 0,188')
Parte pieghevole: 559 L x 1,6 mm diam. (22 x 0,062')
OM-CP-HITEMP140X2-TD-FP-72 Sonda flessibile: 1829 L x 2,5 mm diam. (72 x 0,1')
Peso:
OM-CP-HITEMP140X2-TD-PT: 85 g (3,0 oz)
OM-CP-HITEMP140X2-TD-FP: 100 g (3,5 oz)
Materiali:
Corpo: acciaio inossidabile 316, PEEK
Sonda pieghevole: acciaio inossidabile 316
Sonda flessibile: cavo isolato in PFA
I modelli OM-CP-HITEMP140X2-TD-PT-1 e OM-CP-HITEMP140X2-TD-PT-5 combinano la sonda rigida ambiente da 5,1 cm (2') con una sonda pieghevole in acciaio inossidabile da 61 cm (24'), dotata di una guaina sonda da 2,5 cm (1') o 12,7 cm (5') all'estremità. Le opzioni di sonda PT in acciaio inossidabile consentono di mantenere la forma una volta piegate e offrono un intervallo di misura estremamente elevato fino a 350°C.
Il modello OM-CP-HITEMP140X2-TD-FP-72 combina la sonda rigida ambiente da 5,1 cm (2') con una sonda RTD flessibile leggera da 183 cm (72'), progettata per una facile collocazione. L'opzione di sonda flessibile è molto malleabile e rivestita con isolamento in PFA, ideale per l'uso all'interno di piccole fiale e provette. Questo tipo di sonda ha un diametro ridotto, alta precisione ed è ideale per sterilizzazione a vapore e liofilizzazione. La sonda flessibile è anche compatibile con l'accessorio sonda OM-CP-MICRODISC, utilizzato per il monitoraggio della temperatura superficiale di scaffalature e altro.
L'intervallo di temperatura operativa per il corpo del registratore è da -40 a 140°C (-40 a 284°F). Grazie alla registrazione simultanea della temperatura ambiente e remota, la serie OM-CP-HITEMP140X2-TD è ideale per l'uso nella mappatura di autoclavi, applicazioni di lavorazione alimentare e molto altro.
La serie OM-CP-HITEMP140X2-TD utilizza l'ultimo software disponibile. Ciò consente un semplice avvio, arresto e scaricamento dei dati raccolti. I dispositivi possono memorizzare fino a 32.700 letture con data e ora in memoria solida non volatile. Una volta scaricate nel software, le letture possono essere visualizzate in forma grafica, tabellare e riepilogativa per una facile analisi, oltre alla possibilità di esportarle in Excel per ulteriori calcoli.
L'OM-CP-MULTIMOUNT-Z è un supporto versatile per l'uso con la serie OM-CP-HITEMP140 di registratori di dati. Può essere utilizzato per stabilizzare un registratore all'interno di un autoclave o fissato a una superficie piana per creare una base ancorata. Realizzato in acciaio inossidabile 316, l'OM-CP-MULTIMOUNT-Z è in grado di resistere a temperature fino a 150°C (302°F), rendendolo ideale per processi di sterilizzazione in autoclave.
SPECIFICHE
TEMPERATURA
Sensore di temperatura:
OM-CP-HITEMP140X2-TD-PT-1,
OM-CP-HITEMP140X2-TD-PT-5: Sonda RTD rigida ambiente con sonda RTD pieghevole in acciaio inossidabile
OM-CP-HITEMP140X2-TD-FP-72: Sonda RTD rigida ambiente con sonda RTD flessibile isolata in PFA
Intervallo di misura della sonda:
Sonda rigida ambiente: -200 a 260°C (-328 a 500°F)
Sonda pieghevole in acciaio inossidabile: -200 a 350°C (-328 a 662°F)
Sonda flessibile: -60 a 260°C (-76 a 500°F)
Risoluzione della temperatura: 0,01°C (0,02°F)
Precisione calibrata: ± 0,1°C (± 0,18°F)
GENERALE
Frequenza di lettura: 1 lettura al secondo fino a 1 lettura ogni 24 ore
Memoria: 32.767 letture
Modalità di avvio:
• Avvio immediato programmabile via software
• Avvio ritardato fino a 18 mesi in anticipo
Modalità di arresto: Manuale o temporizzato (data e ora specifiche)
Registrazione in tempo reale: Può essere usato con PC per monitorare e registrare dati in tempo reale
Protezione con password: È possibile programmare una password opzionale nel dispositivo per limitare l'accesso alle opzioni di configurazione. I dati possono essere letti senza password
Numero di letture in modalità impostazioni trigger: 16.383 letture
Impostazioni trigger: Possono essere impostati limiti alti e bassi. Una volta che i dati raggiungono o superano i limiti impostati, il dispositivo registra in memoria. Possono essere programmati trigger di avvio e arresto a due livelli. Gli utenti possono specificare il numero di letture da effettuare dopo l'attivazione del trigger. (Attivazione solo sul canale 1)
Memoria circolare: Sì (selezionabile via software)
Tipo di batteria: Batteria al litio ad alta temperatura da 3,6V inclusa; sostituibile dall'utente
Durata della batteria: 1 anno tipico [frequenza di lettura 1 minuto a 25°C (77°F)]
Calibrazione: Calibrazione digitale tramite software
Data calibrazione: Registrata automaticamente nel dispositivo
Formato dati: Data e ora con timbro °C, °F, °R, K
Precisione temporale: 1 minuto/mese a 25°C (77°F)
Interfaccia computer: Richiede stazione docking USB OM-CP-IFC400 o interfaccia multiplexer OM-CP-IFC406; 125.000 baud
Software: Windows XP SP3/Vista/7 e 8 (32-bit e 64-bit)
Ambiente operativo: -40 a 140°C (-40 a 284°F), 0 a 100% UR, 0,002 a 100 psia
Classe di protezione: IP68
Dimensioni (corpo): 48 H x 24,6 mm diam. (1,89 x 0,97')
Dimensioni (sonda):
Sonda rigida ambiente (tutti i modelli): 51 L x 3,2 mm diam. (4,8 mm diam. di transizione);
2,0 x 0,125' (0,188' diam. di transizione)
OM-CP-HITEMP140X2-TD-PT-1
Sonda pieghevole in acciaio inossidabile:
Punta sonda: 42 L x 3,2 mm diam. (1,7 x 0,125')
Parte pieghevole: 559 L x 1,6 mm diam. (22 x 0,062')
OM-CP-HITEMP140X2-TD-PT-5
Sonda pieghevole in acciaio inossidabile:
Punta sonda: 121 L x 3,2 mm diam. (4,8 x 0,125') con manico 25 L x 4,8 mm diam. (1 x 0,188')
Parte pieghevole: 559 L x 1,6 mm diam. (22 x 0,062')
OM-CP-HITEMP140X2-TD-FP-72 Sonda flessibile: 1829 L x 2,5 mm diam. (72 x 0,1')
Peso:
OM-CP-HITEMP140X2-TD-PT: 85 g (3,0 oz)
OM-CP-HITEMP140X2-TD-FP: 100 g (3,5 oz)
Materiali:
Corpo: acciaio inossidabile 316, PEEK
Sonda pieghevole: acciaio inossidabile 316
Sonda flessibile: cavo isolato in PFA
Software & Drivers
Accessories
accessories
Secure Software for Use with OM-CP Series Data Loggers
2.526,92 € / each
0 In Stock
meters/controllers
Soporte/soporte para registradores de datos de la serie OM-CP-HITEMP140
81,69 € / unidad
0 In Stock