1-800-663-4209 | Vos commentaires sont importants, répondez à un sondage rapide commentaires sur le site web

FMA1600-Series
Débitmètres massiques et volumétriques 0,5 à 1m³/mn pour 14 gaz
Modèles en stock
FMA1600-Series
Depuis
C$
1,350.00
Modèles en stock

L'aperçu du produit
Accessories
Portable battery pack cradle. Not for use with the in-B in portable meter version
C$375.00
0 In Stock
Afficher les notes et les avis
Rated 4 out of
5
by
Ehgid from
Good Mass Flowmeter
Easy to setup and reliable. Easy to use. Remote operation needs expert installation but is easy to use after setup. Price could be lower to have a broader application.
Date published: 2016-11-17
Rated 5 out of
5
by
Kramers31 from
Flow meter
Omega flow meter works as described for use in a test laboratory
Date published: 2025-01-26
Rated 5 out of
5
by
Duc VuLuong from
Accurate and reliable
Bought this flow meter to measure and calibrate the flow rate of Helium and Argon for a protein analyzer instrument. Without the meter, it's virtually impossible to know the exactly flow rate to calibrate it since the instrument doesn't response to change in flow rate. We waste a lot of precious Helium gas due to that. Now that it's calibrated, we can save money in the long run. Awesome!
Date published: 2024-07-31
Rated 5 out of
5
by
Prof YUYE J TONG from
High performance flow meters
My laboratory have ordered 2 1617A and 4 1619A flow meters and been satisfied with their performance.
Date published: 2023-12-17
Rated 3 out of
5
by
Evan121212 from
Need better software
IT works well, but would love to see a better user interface to connect it to PC. Using PuTTY kind of sucks.
Date published: 2023-08-07
Rated 5 out of
5
by
Shan from
Highly recommend
Great product! I was worried this wouldn't arrive in time for when it was needed but very quick!
Date published: 2023-07-26
Rated 5 out of
5
by
Jon F from
As Advertised
Worked as advertised. No issues. seems robust for out testing environment
Date published: 2023-03-20
Rated 3 out of
5
by
chuckd from
2 units defective out of box
The negative terminal was shorted to the body of the sensor and would not work unless the sensor was installed isolated from ground, which we couldn't do in our application. They are easy to disassemble, and the problem was obvious, as one of the wires that connects to the terminal extended about 1/2" past the point that it was soldered at, so the bare wire came into contact with the body of the sensor when it was assembled.
Date published: 2023-01-05
hi how i can connect it to o2 generator @65 psi thank you
Hi, you may connect to the mass flow meter via a machine thread or NPT connection with sufficient straight run pipe or tubing, 10x the diameter of the pipe or tube upstream and 5x the diameter of the pipe or tubing downstream.
Date published: 2019-08-06
What are the voltage levels of the RS232 signals? -12V to +12V?
Thank you for your inquiry. The mass flow meters have by factory default a 0 to 5V signal output or as an option a 4 to 20 mA and the RS232 is available as serial communication.
Date published: 2022-10-19
Hi, is FMA-1601A usable for LPG with H2S and RSH mixture?
Thank you for your inquiry about the mass flow meter. There is an option listed in themanual for the '-LSS' version that handles corrosive gases such as the H2S listed. You may submit a request for a quote to flow@omega.com with the estmated flow range to prepare the part number required.
Date published: 2022-12-03
What is the minimum inlet pressure of the 0-5 SLPM model?
Thank you for your inquiry. The minimum pressure required is 1 PSI
Date published: 2024-08-07
Can this sensor measure the flow rate of a duct with a mixture of air, dust, and particles? Is this sensor compatible with the program NodeRED?
Thank you for your inquiry. It is not recommended to have suspended particles in the air stream and will result in clogging the internal flow path and cause damage. This flow meter requires that the air flow be clean and dry and if the NodeRED can accept an analog input from the flow meter's output, yes.
Date published: 2024-12-09
I am interested in using Modbus protocol via RS232/RS485 to poll data from this instrument. Is this possible? And if so, what register address corresponds to what type of data (ie Mass flow, Volumetric flow, Pressure and Temperature)?
Thank you for your inquiry. The manual for the MODBUS communication protocol is found in the Downloads & Software Manuals Tab.
Date published: 2024-02-11
Hi, does this flow meter work for steam at low vapor pressure (< 1 psia)?
Thank you for your inquiry. Unfortunately, the mass flow meter is best for only clean, dry gases, not for steam applications.
Date published: 2025-02-14
Can you confirm the resolution of each meter is 0.01% of full scale range or better?
Thank you for your inquiry. Please email the Flow Group at flow@dwyeromega.com and can advise.
Date published: 2024-04-26
RoHS 2015/863 - Voir le certificat
Approuvé CE