Web-based temperature monitoring

  • Virtual Chart Recorder
  • Web Server
  • Dual Thermocouple (10 Types)
  • Alarms by Email or Text Message
ISD-TC-Series
From $ 1,001.72
Web-based temperature monitoring ISD-TC-Series ISD-TC-Series
loading all models
Product Overview
  • AC Adaptor Operating Temperature 0 to 40 °C
  • Alarm Two contact inputs, TTL 0.5 mA with 10K pull-up; one open collector output 150 mA @ 30 Vdc
  • Approvals CE, FCC-B
  • Battery Operating Temperature -18 to 55 °C
  • Battery Size and Type Alkaline 9V
  • Cable Temperature, Max 125 °C
  • Cable Temperature, Min -40 °C
  • Configuration Internal Web UI
  • Data Interface Ethernet
  • Data Interface Note Ethernet : (RJ45) Fixed or auto negotiating 10/100BASE-T, AUTO MDI/MDIX Protocols: TCP, UDP, SNMP, SMTP, NTP, ARP, ICMP, DHCP, DNS, HTTP, and Telnet
  • Display LCD
  • Display Note 32 digits 4.8 x 9.7 mm (0.19 x 0.38")
  • Form factor Wall Bracket Mount
  • Height 1.31 in
  • Input Type External
  • Length 3.47 in
  • Measurement Type Thermocouple
  • Memory 2 GB SD Flash Card
  • Memory Note 2GB card: 8 months of data storage at 1 second recording intervals or 7 years at 10 second intervals
  • Number of Measurements 2
  • Number of Relays 2
  • Operating Temperature, Max 60 °C
  • Operating Temperature, Min 0 °C
  • Relay Output 1.5 A @ 30 Vdc
  • Samples,Max 85k Samples, Interval 16 Samples / Second, 1 Second recording intervals or 7 years at 10 sec intervals
  • Sensor Type Thermocouple
  • Software OPC Server; macro for data logging in Excel program; compatible with Windows® operating systems
  • Storage Temperature, Max 85 °C
  • Storage Temperature, Min -40 °C
  • Supply Power Note Safety Qualified AC Power Adaptor:, Input: 100 to 240 Vac, 50/60 Hz, Nominal Output: 9 Vdc @ 0.5 A,(included), Back-up Battery: 9 Vdc, alkaline (included)
  • Supply Power Type DC/Battery
  • Supply Voltage 9 to 12 Vdc
  • Temperature Stability 0.08°C/°C
  • Thermocouple Cold End Tracking 0.05°C/°C
  • Thermocouple Lead Resistance 100 Ω max
  • Weight 1.02 lb
  • Width 5.13 in
Web-based temperature monitoring ISD-TC-Series provides a convenient and efficient way to track temperature data remotely through an online platform. This system allows users to access real-time temperature readings from any location with internet connectivity, ensuring continuous monitoring and timely alerts. Ideal for applications requiring precise temperature control, it enhances safety, compliance, and operational efficiency by offering easy data visualization, logging, and reporting features.
Rated 3 out of 5 by from Solid product, but complicated to set up We recently purchased the iSD-TC for remote temperature monitoring and email alerts for laboratory processes. The product is well made and durable. Temperature readouts are consistent and clear. However, we're still trying to get it to connect directly to a computer or directly to the internet. Contacted customer support, and they just gave me a link to the manual. It's definitely not plug-and-play. If we could get it to connect, upload, and give results within a day after receiving, this review would be 5 stars.
Date published: 2017-10-16
Rated 1 out of 5 by from Extremely unreliable We have 3 of these units on our drug coolers and have now had to throw away several lots worth over $100k because their OS freezes up randomly when attached to a network. Unfortunately it doesn't give you a warning when it freezes up, it just stops recording critical data. We ordered brand new units thinking it would fix the problem and the new unit's OS froze up within two days. Hope they fix this bug as it would be a decent product otherwise. Their tech support was not helpful whatsoever.
Date published: 2022-02-04
Rated 2 out of 5 by from Would be a great product but very buggy. I've had nothing but headaches with the three units we have onsite. They regularly freeze up and lose communication. When they freeze up they still display "Data Recording" but are not actually recording data which resulted in our company having to throw away thousand of dollars in product. I hope they work out the bugs and they might be good units.
Date published: 2021-04-15
Rated 4 out of 5 by from Great, but replacing the battery is a hassle Been buying these for years for our minus 80 freezers since it is one of the few units that can read temperatures so low. My only complaint is that the unit has to be taken apart in order to replace the 9v backup battery, which has to be done about every 8 months. It would really improve the product if that was fixed. Tech support has always been helpful too.
Date published: 2020-05-09
Rated 5 out of 5 by from We have over 10 of these, Great Product I've installed these over a year ago and they have paid for themselves over and over. There are 2 ways to connect to these to get data, but i prefer the Omega Enterprise Gateway which is able to display all on one page. The other way is to connect to the IP address of the monitor. Both work, alarms are invaluable. Great Product, came back here because i'm buying more.
Date published: 2019-04-15
Rated 1 out of 5 by from Unable to obtain data Just like the previous comment, I am unable to download the data as well. Please advise a fix.
Date published: 2018-07-30
  • y_2025, m_10, d_15, h_8
  • bvseo_bulk, prod_bvrr, vn_bulk_3.0.42
  • cp_1, bvpage1
  • co_hasreviews, tv_0, tr_6
  • loc_en_US, sid_ISD-TC, prod, sort_[SortEntry(order=HELPFULNESS, direction=DESCENDING), SortEntry(order=POSITIVE_FEEDBACK, direction=DESCENDING), SortEntry(order=SUBMISSION_TIME, direction=DESCENDING)]
  • clientName_omega
  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • CLOUD, getReviews, 4ms
  • REVIEWS, PRODUCT

how can i calibrate and write offset values or table to this instrument. Omega i server , ISD-TC

Asked by: kalyan
Please direct your question to our DAS Engr dept -DAS@OMEGA.COM
Answered by: Raptor
Date published: 2020-12-09

where can i find a upgrade for firmware?

Asked by: solli
Thank you for your question. We will require more information to help on this question, please email the DAS team at DAS@OMEGA.COM
Answered by: Application Engineer PV
Date published: 2022-08-04

Is a battery required if I don't care about recording if power is disconnected? Will the unit still function normally w/o a battery installed?

Asked by: Jim B
Yes, ac power only is ok
Answered by: Atmos
Date published: 2020-06-18

Does the isd-tc have a count down timer that freezes the unit when trying to make entries online?

Asked by: mbro
Thank you for your question. There is no count down timer that will freeze the unit while making entries.
Answered by: Application Engineer PV
Date published: 2022-08-18

What is the part number of the Power Adapter? I need to do NRTL certification and have to provide this information for that testing.

Asked by: John from Denver
Hello John Replacement power supply part number is UNIV-AC-100/240-12-5A
Answered by: JA Engineer
Date published: 2021-03-16
  • y_2025, m_10, d_15, h_8CST
  • bvseo_bulk, prod_bvqa, vn_bulk_3.0.42
  • cp_1, bvpage1
  • co_hasquestionsanswers, tq_5
  • loc_en_US, sid_ISD-TC, prod, sort_[SortEntry(order=NUM_ANSWERS, direction=DESCENDING)]
  • clientName_omega
  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • CLOUD, getContent, 2ms
  • QUESTIONS, PRODUCT
en-US
en
Save Configuration