Skip to search Skip to main content Skip to navigation

Need assistance? Call us: 1-800-663-4209

We noticed you are in , please visit your local site by clicking the below link for regional offers and support.

FDT-25W-Flow-Meter

Wall Mount Ultrasonic Flow Meter

Models In Stock
  • Permanent metering for lift stations, pump discharge, plant sub-metering, and chilled water loops.
  • Wall-mount transmitter with remote clamp-on transducers, ±1% accuracy, and 4-20 mA and RS-485 outputs.
  • Wall-mount clamp-on ultrasonic flow meter for permanent, non-invasive pipe flow measurement.
  • Retrofits onto existing pipe in place of an inline meter — no cutting, no flanges, no wetted parts.
FDT-25W-Flow-Meter
From $ 1,992.95
Models In Stock
Wall Mount Ultrasonic Flow Meter FDT-25W-Flow-Meter FDT-25W-Flow-Meter
loading all models
Product Overview
  • Accuracy ± 1 %
  • Accuracy Detail ±1% of reading at rates >(0.2m/s) 0.6 ft/s
  • Cable Length 5 m
  • Data Interface BACnet MS/TP, Modbus RTU, USB
  • Display Language English, Chinese
  • Display Note LCD with Backlight
  • Display Type LCD
  • Electrical Output 4 to 20 mA
  • Enclosure Ratings IP65
  • Materials Steel, Stainless Steel, Cast Iron, Cement, Copper, PVC, Aluminum, FRP
  • Measurement Type Transit Time
  • Number of Outputs 1
  • Operating Temperature, Max 80 °C
  • Operating Temperature, Min -30 °C
  • Pipe Size, Max 4 in
  • Pipe Size, Min 0.75 in
  • Process Temperature, Max 90 °C
  • Process Temperature, Min -30 °C
  • Relative Humidity 85% RH
  • Repeatability 0.002
  • Response Time 0 to 999 sec
  • Series ID FDT-25W-Flow-Meter
  • Supply Power Type AC/DC
  • Supply Voltage 220 Vac / 24 Vdc
  • Transducer Type Clamp-on
  • Velocity, Max 32 m/s
  • Velocity, Min -32 m/s

Supported Applications

The Omega FDT-25W is a wall-mounted, clamp-on ultrasonic flow meter designed for long-term flow measurement in closed conduits. Operating on the transit-time principle, it measures fluid velocity by calculating the difference in sound travel time between upstream and downstream paths using two transducers that function as both transmitters and receivers.

Documented applications include:

  • HVAC systems
  • Water conservation projects
  • Metalurgy processes
  • The chemical industry
  • Running water monitoring

Operating Conditions & Performance

The FDT-25W is engineered for non-contacting operation, allowing installation on the outside of closed pipes without process interruption. The device supports a wide range of pipe materials including metallic, plastic, and rubber tubes.

  • Accuracy: ±1% of reading at rates >0.2 mps
  • Repeatability: 0.20%
  • Ambient Temperature Range: -30°C (-22°F) to 80°C (176°F)
  • Process Temperature Range: -30°C to 160°C
  • Humidity Rating: Up to 85% RH
  • Response Time: 0~999 seconds, user configurable

The meter accommodates various liquids capable of transmitting ultrasonic signals uniformly, including water (hot, chilled, city, sea), sewage with small particle content, industrial effluent, acids and alkali liquids, alcohol, beer, ultra-pure liquids, solvents, and all kinds of oils.

Configuration Options

The FDT-25W series supports multiple mounting configurations depending on pipe size and liquid characteristics: V-method (sound traverses the pipe twice), W-method (sound traverses four times), or Z-method (transducers mounted on opposite sides, sound crosses once).

Transducer Options

The system is supplied with a standard STD-WS transducer. Additional clamp-on transducers are available to cover specific pipe sizes and temperature ranges:

  • Standard Temperature (0 to 90°C):
  • STD-WS: DN15 to DN100 (3/4" to 4")
  • STD-WM: DN50 to DN700 (2" to 28")
  • STD-WL: DN300 to DN6000 (12" to 240")
  • High Temperature (0 to 160°C):
  • HT-WS: DN15 to DN100 (3/4" to 4")
  • HT-WM: DN50 to DN700 (2" to 28")
  • HT-WL: DN300 to DN6000 (12" to 240")

Outputs and Connectivity

The meter provides multiple output signal options including:

  • RS485 Output
  • 4 to 20 mA current loop output
  • Totalizer Pulse Output (Frequency)
  • OCT output
  • RS232/RS485 communication

The device features a powerful recording function capable of storing totalizer data for extended periods up to 5 years. Electrical connections utilize twisted pair lines, and the unit operates on AC/DC power.

Accessories

Supporting accessories include acoustic gels (STDGEL for standard transducers, HTGEL for high temperature), pipe clamps sized up to DN1000/40" (CLAMP1, CLAMP2, CLAMP3), and a 5-meter transducer cable pair (TCH).

Key Product Differences

The primary variation within the FDT-25W series is defined by the selected clamp-on transducer type. Standard temperature transducers are rated for process temperatures up to 90°C, while High Temperature variants extend this capability to 160°C.

  • Standard Transducers (STD): Designed for pipe sizes ranging from DN15 to DN6000 across small, medium, and large configurations with a maximum process temperature of 90°C.
  • High Temperature Transducers (HT): Match the same pipe size ranges as standard models but are rated for processes up to 160°C.

The FDT-25W unit itself is a wall-mount enclosure with overall dimensions of 210mm width, 251mm height, and 96mm depth. The series does not include wetted materials as the transducers are non-contacting clamp-on types.

Accessories

consumables

Acoustic Gel for High Temperature Transd
$53.61 / each
37 In Stock
Acoustic Gel for Standard Transducers (0
$40.23 / each
16 In Stock

installation hardware

STEEL BELT- FOR UP TO DN700/28"
$66.18 / each
1 In Stock
STEEL BELT- FOR UP TO DN300/12"
$48.94 / each
0 In Stock
STEEL BELT- FOR UP TO DN1000/40"
$87.08 / each
0 In Stock

sensors

HI-TEMP CLAMP-ON TRANSDUCER - LARGE 0-16
$534.05 / each
0 In Stock
HI-TEMP CLAMP-ON TRANSDUCER - MEDIUM 0-1
$503.50 / each
0 In Stock
HI-TEMP CLAMP-ON TRANSDUCER - SMALL 0-16
$503.50 / each
0 In Stock
STANDARD CLAMP-ON TRANSDUCER - MEDIUM 0-
$487.23 / each
1 In Stock
STANDARD CLAMP-ON TRANSDUCER - LARGE 0-9
$492.08 / each
0 In Stock
STANDARD CLAMP-ON TRANSDUCER - SMALL 0-9
$485.50 / each
0 In Stock
  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • CLOUD, getReviews, 4ms
  • REVIEWS, PRODUCT
  • bvseo-msg: The resource to the URL or file is currently unavailable.;

Our data collection system has a powered 4-20mA loop, this device also has a powered 4-20mA loop, is there a way to turn off the power to the loop in the FDT-25W and let our DAQ power the loop?

Asked by: Electrical Engineer
Thank you for your inquiry! The FDT-25W can be wired for an active or passive 4-20 loop. If power is supplied by the data acquisition system you will use 23 (AO+) and 25 (LPIN) rather than 23 and 24.
Answered by: Application Engineer JM
Date published: 2023-04-28

Does the unit come with the red/ blue transducer cables? It does not show up under "whats included" and the model number "TCH" is not under the accessories page.

Asked by: dwilson01
Thank you for your inquiry. The transducer is included for pipe diameters from 3/4 to 4 inch which is found in the Accessories Tab.
Answered by: Applications Engineer JJC
Date published: 2025-05-27

In an earlier question it was asked what is included in the FDT-25W (for example transducers and cabling). The answer provided stated "Yes, it is in the Accessories Tab." Where is this "Accessory Tab?" I do not see any Tabs.

Asked by: DanOU812
Thank you for your inquiry. Please contact our Flow Department at 1-888-826-6342 or flow@omega.com regarding this request.
Answered by: Application Engineer CB
Date published: 2025-05-28

In ultrasonic Flowmeter TDS-100 Ver18.56. The Menu 2. (2A) "Maxmium Flowrate". It isn´t in usermanual. Wich is the function of this parameter? What we should consider to enter this value? Do you have documentation about it? Help us please.

Asked by: luisgalo
Thank you for your inquiry about the ultrasonic flow meter. Please email the Flow Group at flow@omega.com and can advise with our Design Engineering Group
Answered by: Applications Engineer JC
Date published: 2021-08-05

Does this model FDT-25W work on ductile iron pipe (18.75mm thick) having inner lining of cement mortar (12.5 mm thick)?

Asked by: Anonymous
Thank you for your inquiry about the ultrasonic flow meter. Unfortunately, it will not work as a result of the liner indicated.
Answered by: Application Engineer JC
Date published: 2022-06-06

We are using a doppler flow meter but the clenliness of the water varies quite a bit and when it is too clean we don't get accurate readings. How dirty can the water get and still be read accuratly with transit time?

Asked by: Chuck B
Thank you for your inquiry about the Transit Time ultrasonic flow meter. Transit Time works best when the liquid is clean or below 100 microns in particle size AND less than 100 ppm in concentration. In the event there is some suspended particles, it will not detect it since it is very small.
Answered by: Applications Engineer JC
Date published: 2021-04-29

Good afternoon. When there is no liquid circulation in the pipe and the meter also indicates a instant value of flow, how to solve this? How can I reset it or put a minimum cut on it? BR

Asked by: OscarBsAs
Thank you for your inquiry. Please email the Flow Group at flow@dwyeromega.com and can provide the information you requested.
Answered by: Applications Engineer JJC
Date published: 2024-03-07

Will this flow meter work with a refrigerant as the liquid?

Asked by: Exergy Engineer
Thank you for your inquiry! This flow meter will work with nearly all clean liquids. Menu 20 in the programming can be used to select standard fluid types like water or oil. For non standard fluids not listed in menu 20 the fluid parameters can be entered in menus 21-23 to accurately represent the process media.
Answered by: Application Engineer JM
Date published: 2022-09-28
  • y_2026, m_8, d_10, h_10CST
  • bvseo_bulk, prod_bvqa, vn_bulk_3.0.48
  • cp_1, bvpage1
  • co_hasquestionsanswers, tq_19
  • loc_en_US, sid_FDT-25W, prod, sort_[SortEntry(order=NUM_ANSWERS, direction=DESCENDING)]
  • clientName_omega
  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • CLOUD, getContent, 3ms
  • QUESTIONS, PRODUCT
en-US
en
Save Configuration