Product Overview
  • Additional Features 1 SD Card Data Logger, Includes UVA/UVC Probes
  • Battery Size and Type Alkaline AA
  • Display Size 52 x 38 mm (2.05 x 1.5 in)
  • Display Type Backlit LCD
  • Height 177 mm
  • Input Type Thermocouple (Type J,K)
  • Length 68 mm
  • Measurement Note Full-Scale Autoranges: 2 mW/cm^2 and 20 mW/cm^2
  • Memory Max/Min
  • Memory Card 1 to 16 GB
  • Operating Humidity 0 to 85% RH
  • Operating Temperature, Max 50 °C
  • Operating Temperature, Min 0 °C
  • Sampling Time 1 sec to 1 hr
  • Series ID HHUV254SD-Meter
  • Supply Power Type Battery
  • Temperature Range Type K -50 to 1300ºC (±0.2% + 0.5ºC), -50.1 to -100ºC (±0.2% + 1ºC), -58 to 2372ºF (±0.2% + 1ºF), -58.1 to -148ºF (±0.2% + 1.8ºF),Type J -50 to 1200ºC (±0.2% + 0.5ºC), -50.1 to -100ºC (±0.2% + 1ºC), -58 to 2192ºF (±0.2% + 1ºF), -58.1 to -148ºF (±0.2% + 1.8ºF)
  • UV Light Types UVA, UVC
  • Width 45 mm

Supported Applications

The Omega HHUV254SD is a handheld UVA and UVC light meter designed for measuring light intensity in the UVA (365 nm) and UVC (254 nm) bands. The series supports industrial applications including welding, UV sterilization, photochemical matching, EEPROM erasure, graphic arts, photore sist exposure, and curing of inks, adhesives, and coatings.

When mated with a Type K or Type J thermocouple via the dedicated socket (callout 1-8), the meter also measures surface temperature. The device is not designed for use in human applications.

Operating Conditions & Performance

The HHUV254SD operates within an ambient temperature range of 0 to 50°C (32 to 122°F) and a relative humidity of 0 to 85% RH. The meter features automatic switching between two full-scale ranges: 2 mW/cm² and 20 mW/cm², covering wavelengths from 240 to 390 nm.

Performance specifications include:

  • Measurement Accuracy (Light): ±4% of full scale reading + 2 digits.
  • Temperature Measurement Ranges and Accuracy:
  • Type K: -50 to 1300°C (±0.2% + 0.5°C), -50.1 to -100°C (±0.2% + 1°C); -58 to 2372°F (±0.2% + 1°F), -58.1 to -148°F (±0.2% + 1.8°F).
  • Type J: -50 to 1200°C (±0.2% + 0.5°C), -50.1 to -100°C (±0.2% + 1°C); -58 to 2192°F (±0.2% + 1°F), -58.1 to -148°F (±0.2% + 1.8°F).
  • Display: LCD with green backlight, measuring 52 x 38 mm (2.05 x 1.5").
  • Data Logging Sampling Time: Settable from 1 sec to 1 hr.

Variance in Source Data

Note: The family manual lists a response time of 0.5 seconds and an accuracy of ±5% of reading, while the series-specific data sheet specifies light measurement accuracy as ±4% of full scale reading + 2 digits without listing a specific response time value.

Configuration Options

The HHUV254SD is configured with integrated UVA and UVC probes. The meter supports real-time automatic datalogging to SD memory cards ranging from 1 GB to 16 GB, including a supplied 2 GB card. It features an RS232 output jack for data acquisition software connectivity.

Power options include six AA alkaline batteries or an optional 9 Vdc AC adaptor. The meter includes settable parameters such as date, time, auto power off, beep sound, temperature unit (°C or °F), sampling time, thermocouple Type (K or J), and decimal point/comma selection.

Physical dimensions are:

  • Meter: 177 H x 68 W x 45 mm D (6.97 x 2.68 x 1.77").
  • UVA Probe Handle: 24 (diagonal) x 125 mm L (0.94 x 4.92").
  • UVA Probe Head: 45 (diagonal) x 32 mm L (1.77 x 1.26").
  • UVC Probe: 38 (diagonal) x 25 mm L (1.50 x 0.98").

Key Product Differences

The HHUV254SD is a single model configuration that includes the meter, UVA probe, UVC probe, Type K thermocouple, 2 GB SD memory card, hard carrying case, and operator's manual. The series supports optional field-installable accessories including spare 2 GB SD cards (2GB-SD), AC power adaptors (ADAPTER-SD), data acquisition software with RS232 cable (SW-U101-WIN), and spare RS232 interface cables (RS232-SD).

The meter features a subminiature connector for thermocouple input. The OMEGACARE™ extended warranty program is available, extending the standard 1-year warranty to a total of 4 years with OCW-3 coverage.

Rated 5 out of 5 by from Biomedical Engineering Support Specialist Quick and easy order. Good product. Timely delivery
Date published: 2020-04-27
  • y_2026, m_8, d_31, h_10
  • bvseo_bulk, prod_bvrr, vn_bulk_3.0.48
  • cp_1, bvpage1
  • co_hasreviews, tv_0, tr_1
  • loc_en_US, sid_HHUV254SD, prod, sort_[SortEntry(order=HELPFULNESS, direction=DESCENDING), SortEntry(order=POSITIVE_FEEDBACK, direction=DESCENDING), SortEntry(order=SUBMISSION_TIME, direction=DESCENDING)]
  • clientName_omega
  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • CLOUD, getReviews, 3ms
  • REVIEWS, PRODUCT

I need help with exporting the data from this device in real time using the data out function. Can you assist

Asked by: Mike F
Data stored on the SD card can be transferred via a card reader or serial communication cable but there is no capability of viewing live measurements through the RS232 connection on a computer.
Answered by: ApplicationEngineerANB
Date published: 2020-04-24

Is there a NIST certificate of calibration for this unit? If not, what certification is available?

Asked by: Buckwalker123
When this unit ships, it is sent with a 'certificate of conformance' which ensures that the unit has been made to published specifications. We do not provide NIST certification for this unit because of its light functions. However, you can send to an outside lab for certification if you like; again, we do guarantee all specs associated with this device.
Answered by: dfrisby77
Date published: 2022-07-22

What is the wavelength range of the UVC probe?

Asked by: Vvelox
The UVC probe measures the light intensity in the 254-nm band.
Answered by: ApplicationEngineerANB
Date published: 2022-03-21

Can you provide the frequency sensitivity plot of the device?

Asked by: Laine
Unfortunately we do not have that requested information available.
Answered by: ASE HPO
Date published: 2020-09-30
  • y_2026, m_8, d_30, h_13CST
  • bvseo_bulk, prod_bvqa, vn_bulk_3.0.48
  • cp_1, bvpage1
  • co_hasquestionsanswers, tq_4
  • loc_en_US, sid_HHUV254SD, prod, sort_[SortEntry(order=NUM_ANSWERS, direction=DESCENDING)]
  • clientName_omega
  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • CLOUD, getContent, 52ms
  • QUESTIONS, PRODUCT
en-US
en
Save Configuration