Skip to search Skip to main content Skip to navigation

Need assistance? Call us: 1-800-663-4209

We noticed you are in , please visit your local site by clicking the below link for regional offers and support.

OM-THA2-U-Alarm

Temperature Humidity Alarm with Logging Capability

  • Audible and Visual Alarm
  • Digital Display Log Up to 170 Days of Data
  • Relay Contacts for Remote Alarm or Auto Dialer
  • Remote Sensor with USB Connection
OM-THA2-U-Alarm
From $ 671.76
Temperature Humidity Alarm with Logging Capability OM-THA2-U-Alarm OM-THA2-U-Alarm
loading all models
Product Overview
  • Additional Features 1 External Probe
  • Alarm Audible/visual/relay
  • Alarm Delay Up to 2 hrs, user-selectable
  • Base Unit Operating Humidity 0 to 90% RH
  • Battery life 25 hr
  • Battery Size and Type Alkaline 9V
  • Cable Length 4.6 m
  • Calibration User calibration for temperature and relative humidity
  • Data Interface USB
  • Display Type LCD
  • Height 11.4 cm
  • Length 14 cm
  • Measurement Type Relative Humidity, Temperature
  • Memory 8150
  • Memory Note 8150 samples for temperature, humidity and dew point
  • Number of Measurements 2
  • Operating Humidity 0 to 90% RH
  • Operating Temperature, Max 54 °C
  • Operating Temperature, Min 0 °C
  • Probe Diameter 2.79 cm
  • Probe Length 9.65 cm
  • Process Temperature, Max 60 °C
  • Process Temperature, Min -40 °C
  • Relative Humidity Accuracy ± 2% RH
  • Relay Output 5 A @ 250 Vac
  • Sampling Rate 1 Hz (1 update/second)
  • Sampling Rate Note 1 sec to 30 min, user-selectable
  • Sensor Probe Humidity Resolution 0.1 °C
  • Sensor Probe Temperature Resolution 0.1 °C
  • Sensor Probe Weight 25 g
  • Series ID OM-THA2-U-Alarm
  • Software Compatibility Windows XP/Vista/7/8/10 (32-bit and 64-bit)
  • Storage Temperature, Max 54 °C
  • Storage Temperature, Min -18 °C
  • Supply Power Type Battery
  • Temperature Accuracy ± 1 °C
  • Weight 245 g
  • Width 4.1 cm

Supported Applications

The Omega OM-THA2-U is a multi-function unit that monitors temperature, relative humidity, and dew point. It records data and generates an alarm for any out-of-range conditions. Documented applications include supermarkets, food markets, convenience stores, restaurants, florists, greenhouses, laboratories, pharmaceutical storage facilities, refrigerated transport, cold chain facilities, and computer rooms.

Operating Conditions & Performance

The sensor probe operates within a temperature range of -40 to 60°C (-40 to 140°F) and an operating humidity range of 0 to 90% RH non-condensing. The base unit has an operating temperature range of 0 to 54°C (32 to 132°F) and a storage temperature range of -18 to 54°C (0 to 130°F). Performance specifications include ±1°C (±2°F) accuracy for temperature with 0.1°C (0.1°F) resolution, and ±2% RH accuracy for humidity with 0.1% RH resolution.

The unit features a user-selectable sample rate from 1 sec to 30 min. Memory capacity is rated at 8150 samples for temperature, humidity, and dew point, supporting data history storage of 2 hrs to 170 days depending on the sample rate. The system includes a battery backup using a 9V alkaline battery providing 25 hrs operation during power outage.

Alarm & Relay Specifications

  • Alarms: High/low temperature and humidity alarms, condensation alarm with audible/visual indication.
  • Relay Output: 5A/250V NO/NC dry contact for resistive load.
  • Alarm Delay: Up to 2 hrs, user-selectable.

Power & Connectivity

  • Power Supply: 12 to 24 Vac/Vdc (0.78W alarm active).
  • Interface: USB connection with free Windows software compatible with XP, Vista, 7, 8/10 (32-bit and 64-bit).

Configuration Options

The series consists of a base unit with an easy-to-read display and a remote sensor probe. The standard configuration includes a cable length of 4.6 m (15'). The sensor probe dimensions are 9.65 L x 2.79 cm dia (3.8 x 1.1") with a weight of 25 g (0.9 oz). The base unit measures 14 L x 11.4 W x 4.1 cm dia (5.5 x 4.5 x 1.6").

Configuration options and accessories include:

  • NIST Calibration Certificate: Available as an optional add-on.
  • Replacement Parts: Remote sensor probe (OM-THA2P), 115 Vac power adaptor (OM-THA2-ADAP), and 220 Vac power adaptor (OM-THA2-ADAP-220V).
  • Warranty: OMEGACARE extended warranty program available.

The unit supports user calibration for temperature and relative humidity. It comes complete with a user guide, Windows software on CD, USB interface cable, and 115 Vac power adaptor.

Key Product Differences

The series offers specific model variations based on included documentation or accessories:

  • OM-THA2-U: Standard temperature/humidity alarm unit.
  • OM-THA2-U-CAL-3-HU: Temperature/humidity alarm with NIST calibration certificate.
Rated 3 out of 5 by from Needs to be calibrated... Sent out for calibration to a third party because Omega E does not provide cal services for this particular unit. The unit was found out of +/-2% range. At 53.0 %RH read 49.1%RH. At 75.0 %RH read 70%RH.
Date published: 2018-11-29
  • y_2026, m_8, d_3, h_10
  • bvseo_bulk, prod_bvrr, vn_bulk_3.0.48
  • cp_1, bvpage1
  • co_hasreviews, tv_0, tr_1
  • loc_en_US, sid_OM-THA2-U, prod, sort_[SortEntry(order=HELPFULNESS, direction=DESCENDING), SortEntry(order=POSITIVE_FEEDBACK, direction=DESCENDING), SortEntry(order=SUBMISSION_TIME, direction=DESCENDING)]
  • clientName_omega
  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • CLOUD, getReviews, 9ms
  • REVIEWS, PRODUCT

My company doesn't have access to a PC with a CD drive. Can I install the provided software online instead?

Asked by: C3PO
Thank you for your question. We will require more information to help on this question, please email the DAS team at DAS@OMEGA.COM
Answered by: Application Engineer PV
Date published: 2023-09-26

Is there a way to communicate with this device in c# or do you have to use your datalogging software to log device data

Asked by: Sparkthrower
Thank you for your question. Unfortunately, you have to use the provided software, there is no custom programming language support available.
Answered by: Application Engineer PV
Date published: 2021-07-01
  • y_2026, m_8, d_3, h_10CST
  • bvseo_bulk, prod_bvqa, vn_bulk_3.0.48
  • cp_1, bvpage1
  • co_hasquestionsanswers, tq_2
  • loc_en_US, sid_OM-THA2-U, prod, sort_[SortEntry(order=NUM_ANSWERS, direction=DESCENDING)]
  • clientName_omega
  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • CLOUD, getContent, 29ms
  • QUESTIONS, PRODUCT
en-US
en
Save Configuration