CNI-CB120SB-K

Microprocessor-based Controller Self container Temperature controller

Choose a Variant

Thermocouple Type
Power Consumption
Control Output
Supply Voltage

$1,169.44 / each

Item# CNI-CB120SB-K

In Stock

Lead Time (If not in stock): 3 weeks

Product Specs

<< See all Product Models
Brand
Additional Features 1 12A (1440 W) Capacity
Commodity Code 9032.89.6075
Control Output 2 SPST Relay
Data Interface None
Display Type 3.5 Digit Display
ECCN EAR99
Height 203 mm
Input Type Thermocouple, RTD, Voltage, mA
Length 152 mm
Measurement Type Current, Temperature, Voltage
Number of Control Outputs 2
Number of Inputs 1
OkForExport true
Operating Temperature, Max 55 °C
Operating Temperature, Min 0 °C
Output Detail Two 15A Controlled Output Relays
Output Signal None
Power Consumption 3 W
Supply Power Type AC
Supply Voltage 120 Vac
Thermocouple Type K
Weight 4.53 kg
Country of Origin United States
See All Specs Show Less
Microprocessor-based Controller Self container Temperature controller CNI-CB120SB-K CNI-CB120SB-K

Accessories

Field Mountable M8 and M12 Connectors
$21.92 / each
2183 In Stock
Rated 3 out of 5 by from Blends well with my design I operate a press with this control. I only wish there were more than one input.
Date published: 2017-03-01
Rated 4 out of 5 by from Useful It has Been working fine so far. We use them in our test stands.
Date published: 2023-05-07
Rated 1 out of 5 by from Not safe, poorly engineered. Looking at the documentation and diagrams, this unit has no 3rd party approvals, and I see why. The documentation says it has devices rated 20amps in the manual, yet the rated output for the 120V version is 25 amps. Looking at wiring diagrams, control circuit fusing is in the wrong location, and incorrect style of fuses are used. Either someone needs to review and update the documentation, or the units need to be redesigned by someone who knows control panels.
Date published: 2018-07-17
  • y_2025, m_12, d_19, h_5
  • bvseo_bulk, prod_bvrr, vn_bulk_3.0.42
  • cp_1, bvpage1
  • co_hasreviews, tv_0, tr_3
  • loc_en_US, sid_CNI-CB120SB-K, prod, sort_[SortEntry(order=HELPFULNESS, direction=DESCENDING), SortEntry(order=POSITIVE_FEEDBACK, direction=DESCENDING), SortEntry(order=SUBMISSION_TIME, direction=DESCENDING)]
  • clientName_omega
  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • CLOUD, getReviews, 4ms
  • REVIEWS, PRODUCT
en-US
en
Save Configuration