Product Overview
- Accuracy ± 0.5 %
- Approvals CE, UKCA
- Burst Pressure 500 psi Maximum
- Configuration Configurable via Omega Link Smart Interface and SYNC configuration software
- Data Interface USB, Modbus, Wireless
- Digital Input VinHighThreshold = 2.2 VMAX, VinLowThreshold = 0.3 VMIN, VinMAX = 30 VDC
- Digital Output 2x Open Drain 100 mA max, VMAX = 30 VDC
- Enclosure Ratings IP50
- Internal Sensor Accuracy ± 1.5 °C
- Internal Temperature Resolution 0.1°C
- Measurement Type Pressure
- Number of Channels 1
- Number of I/O 2
- Operating Temperature, Max 85 °C
- Operating Temperature, Min -40 °C
- Measurement Pressure, Min 0 psi
- Pressure Resolution 0.1
- Process Connection Size 1/4 in
- Process Connection Type NPT Male
- Process Temperature, Max 80 °C
- Process Temperature, Min -10 °C
- Relative Humidity 95% RH, non-condensing
- Series ID SP-006-Series
- Software Compatible with Omega Enterprise Gateway and SYNC configuration software
- Supply Power Type DC
- Supply Voltage 2.8 to 3.3 Vdc
Supported Applications
The Omega SP-006-Series Smart Pressure Probe is a low-cost smart pressure sensor designed for monitoring and control of gas, liquid, and vapor pressures. The series functions as an edge controller with autonomous decision-making capabilities, featuring integrated alarm and control logic alongside secure authentication and password protection.
Operating Conditions & Performance
The SP-006-Series measures pressure in configurations ranging from 1 psi (6.89 kPa) to 250 psi (1724 kPa), available as Gauge or Absolute types. Accuracy is specified at ±0.5% full-scale with a resolution of 0.1. The device operates within an ambient temperature range of -10 to 80°C and carries an IP50 environmental rating.
Internal sensor monitoring provides temperature data across the same operating range (-10 to 80°C) with ±1.5°C accuracy and 0.1°C resolution. The probe is powered by a battery supply of 2.8 V DC - 3.3 V DC (two alkaline C cells when used with the IF-006 interface). Storage temperature limits are defined as -40 to 85°C at less than 95% RH, non-condensing.
Pressure ratings allow for an absolute maximum of 1.5 times full-scale for each range; a caution note specifies not to exceed 500 psi.
Configuration Options
The series features an all stainless-steel body and housing with wetted materials in Stainless Steel. The standard process connection is 1/4-18 NPT Male, though the series supports various other male and female pressure ports including 1/8-27 NPT, 1/4-18 NPT Female, BSPP 1/8 B, BSPP 1/4 B, 7/16-20 UNF, 9/16-18 UNF, and M12x1.5.
Electrical connectivity is provided via an M12 8-Pin Male Connector supporting the following functions:
- DIO 0 (Discrete I/O Signal 0)
- INTR (Interrupt Signal)
- SCL (I2C Clock Signal)
- SDA (I2C Data Signal)
- Shield Ground
- DIO 1 (Discrete I/O Signal 1)
- GND (Power Ground)
- 3.3VDD (Power Supply)
The probe includes two discrete open-drain digital outputs capable of driving relays or physical alarms, with a maximum current of 200 mA and V_MAX of 30 V DC. Digital inputs support thresholds up to 30 V DC.
Key Product Differences
The SP-006-Series is configurable via Omega Link Smart Interfaces using SYNC configuration software for selective data extraction, measurement traceability, local alarms, and adaptive transmission rates. The series supports storage of 10,000+ sample data points and events.
Connectivity options include:
- USB (IF-001): Wired USB Smart Interface.
- Modbus (IF-002): Wired RS485/Modbus Smart Interface.
- Wireless (IF-006): Long-range wireless capability available in 915 MHz (-NA) and 868 MHz (-EU) variants. The IF-006 must be paired with an Omega Link wireless gateway.
The series is compatible with the Omega Enterprise Gateway and SYNC configuration software. Accessories include shielded T-Splitters (M12.8-T-SPLIT), field install connectors, and dual M12-8 cables in 1m, 3m, and 5m lengths available as straight or right-angle terminators.