Need assistance? Call us: 1-800-663-4209
TX60
Smart and Programmable Linearized Transmitters
The TX60 series has been discontinued. Please see the TX86 as a possible alternative or contact our Data Acquisition Engineering department
- 2 Wire 4-20 mA Output
- TX62 TX64 Models for Thermocouple and RTDs
- TX63 TX65 Models for mV, mA, V, Resistance
- Input to Output Isolation
Product Overview
- Accuracy ± 0.05 %
- Accuracy Detail Transmitter Accuracy:±0.05% of the millivolt or Ω equivalent reading, or the accuracy from the table below, whichever is greater; plus ±0.05% of the span, if using a thermocouple sensor, allow a cold junction measurement error of ±0.5°C (±0.9°F), accuracy includes repeatability, hysteresis, load and ambient temperature Thermocouple Type: J: ±0.2°C K: ±0.2°C T: ±0.2°C E: ±0.2°C R: ±0.6°C S: ±0.6°C B: ±0.8°C N: ±0.2°C RTD Accuracy: ±0.1°C Voltage Accuracy: ±0.008 mV
- Additional Features 1 Programmable temperature transmitter
- Calibration Adjustment 100 % sensor range
- CMRR 120 dB
- Cold Junction Compensation ±0.5°C
- Diagnostics Every 3 seconds, self-checks for zero, span, cold junction, calibration references, malfunction and sensor failure
- Electrical Output 2-wire, 4 to 20 mA
- EMC Immunity Note RFI Effect: <0.5% rdg (SAMA PMC 33.1c test) 20 kHz to 1000 MHz, 10 V/meter
- Input Control Signal -15 to 160 mV
- Isolation 850 Vdc or peak ac
- Linearity Error ±0.05°C
- Load Resistance 250 Ω
- Long Term Stability < 0.05% of reading plus ±5 µA per year
- Operating Temperature, Max 75 °C
- Operating Temperature, Min -40 °C
- Output Signal Current
- Repeatability One-half of accuracy
- Resolution ±2.5 µA
- Response Time 0.25 sec; Update Time: 0.15 sec, digital, 1 sec
- Response Time Note Analog 0.25 second typical; digital 1 second, typical to 95% of final value, 5 seconds to stated accuracy (Response to Step Input)
- Reverse Voltage 42 Vdc applied with either polarity
- RTD Type 100 Ω Pt Sensor,120 Ω Ni Sensor
- Sensor Break Detection Analog, user settable to 21 mA, 3.9 mA or “OFF”, digital
- Series ID TX60
- Start Up Time <5 sec
- Storage Temperature, Max 85 °C
- Storage Temperature, Min -50 °C
- Supply Power Note Minimum supply voltage under load, Vs = 12 + R (load in kΩ) X 23 mA; for digital operation
- Supply Power Type DC
- Supply Voltage 12 to 42 Vdc
- Temperature Compensation Automatic compensation to 20°C/hour change, Self-correcting over operating temperature range
- Temperature Measurement Range J: -210 to 1200°C, K: -270 to 1372°C, T: -270 to 400°C, E: -270 to 1000°C, R: -50 to 1768°C, S: -50 to 1768°C, B: 43 to 1820°C, N: 0 to 1300°C, RTD: -200 to 850°C
- Thermocouple Type J, K, T, E, N, R, B, S
- Weight 340 g
The TX60 series has been discontinued. Please see the TX86 as a possible alternative or contact our Data Acquisition Engineering department.
The TX62 and TX64 programmable transmitters provide an isolated 4 to 20 mA signal linearized to temperature or process input.
The TX62 and TX64 programmable transmitters provide an isolated 4 to 20 mA signal linearized to temperature or process input.