TJ36-XCIB

Rugged Thermocouple Transition Joint Probes with Nextel® Insulation

Models In Stock
  • 304 SS and Inconel® 600 Sheaths in Stock
  • 1000 mm (40") Lead Length
  • 304 SS and Inconel® 600 sheaths. Additional Sheaths Available: 310 SS, 316 SS, 321 SS and Super OMEGACLAD™ XL
  • Nextel Ceramic Insulated Lead Wire Rated to 815°C (1500°F)
TJ36-XCIB
From $ 118.04
Models In Stock
Rugged Thermocouple Transition Joint Probes with Nextel® Insulation TJ36-XCIB TJ36-XCIB
loading all models

Can't find the right model?

Use our custom configurator to fine tune your product

Product Overview
  • Additional Features 2 Dual Elements
  • Number of Connectors N/A
  • Process Temperature, Max 920 °C
  • Process Temperature, Min 0 °C
  • Series ID TJ36-XCIB
  • Temperature Sensor Type Thermocouple

Supported Applications

The Omega TJ36-XCIB series consists of rugged thermocouple transition joint probes designed for harsh conditions. These sensors utilize Super OMEGACLAD® XL Compacted Mineral Insulation Cable with an Inconel® 600 braid over Nextel® lead wire to provide robust temperature measurement in demanding environments.

Operating Conditions & Performance

The series meets or exceeds IEC 584-1 and EN 60584-2 Tolerance Class 1. The transition joint design supports a process temperature up to 815°C (1500°F) for the lead wire, while junction temperatures vary by calibration type:

  • K Type: Up to 1204°C (2200°F)
  • J Type: Up to 721°C (1330°F)
  • T Type: Up to 371°C (700°F)

Upper temperature guidelines for the T/C junction also depend on sheath material and diameter. For example, K CHROMEGA®-ALOMEGA® probes with a Super OMEGACLAD® XL sheath at 4.78 mm (3/16 in) or 6.35 mm (1/4 in) support up to 1204°C (2200°F), whereas the same calibration with a 304 SS sheath supports up to 899°C (1650°F).

Configuration Options

The TJ36-XCIB series is configurable across multiple parameters including sensor type, sheath material, diameter, junction style, and probe length.

  • Sensor Types: K CHROMEGA®-ALOMEGA®, J IRON-CONSTANTAN, T COPPER-CONSTANTAN
  • Sheath Materials: 304 SS, Inconel® 600 (INC 600), Super OMEGACLAD® XL (XL)
  • Diameters: 1.59 mm (1/16 in) to 6.35 mm (1/4 in)
  • Junction Types: Grounded, Ungrounded, Exposed
  • Probe Lengths: Standard overall length is 1000 mm (40 in); stock lengths include 150 mm (6 in), 300 mm (12 in), and 450 mm (18 in)

The standard electrical connection features stripped leads. M8/M12 connectors are available as an option by adding specific codes to the model number.

Key Product Differences

Variants within the series differ primarily by calibration code, sheath material selection, and physical dimensions which dictate maximum operating temperatures. Model numbers follow the format TJ36------CC-XCIB.

Specific configurations include:

  • K Type with 304 SS sheath (1.59 mm): TJ36-CASS-116(*)-(**)-CC-XCIB, rated to 899°C (1650°F)
  • K Type with Inconel® 600 sheath (4.78 mm): TJ36-CAIN-316(*)-(**)-CC-XCIB, rated to 1149°C (2100°F)
  • J Type with 304 SS sheath (6.35 mm): TJ36-ICSS-14(*)-(**)-CC-XCIB, rated to 721°C (1330°F)
  • T Type with 304 SS sheath (4.78 mm): TJ36-CPSS-316(*)-(**)-CC-XCIB, rated to 371°C (700°F)

The series is Made in USA.

Rated 5 out of 5 by from Does the job. The company i work for uses these for process controls they last a long time and are very reliable.
Date published: 2016-04-14
Rated 5 out of 5 by from Best Thermocouples money can buy! These thermocouples are very well made, and very reliable!
Date published: 2026-07-16
Rated 4 out of 5 by from My top choice for temperature sensors. Omega is a direct manufacturer of many temperature sensors used by other equipment manufacturers, and it's much cheaper to work with Omega when sourcing replacement sensors. Omega is always my top choice for temperature sensors.
Date published: 2026-05-18
Rated 5 out of 5 by from Furnace Mapping K Type Thermocouples for use to monitor furnace temperature. Worked as expected for the furnace to map and monitor thermal gradients.
Date published: 2026-04-27
Rated 5 out of 5 by from High quality High quality thermocouple that just works right out of the box
Date published: 2025-12-04
Rated 5 out of 5 by from Great quality These are great and last for over a decade in our application.
Date published: 2025-11-30
Rated 5 out of 5 by from Just what we needed The website was easy to follow and get to what I needed. The item was in stock and shipped promptly. As soon as it arrived, we installed it and put it to work. It got our heat treating oven back to work with minimum downtime.
Date published: 2025-11-21
Rated 5 out of 5 by from Great wood-fired kiln thermocouples We fire our wood kiln to cone 15 and really torture these thermocouples and they hold up well.
Date published: 2025-08-25
  • y_2026, m_9, d_7, h_9
  • bvseo_bulk, prod_bvrr, vn_bulk_3.0.48
  • cp_1, bvpage1
  • co_hasreviews, tv_0, tr_38
  • loc_en_US, sid_TJ1-CAIN-IM15U-200-CC-XCIB-DUA, prod, sort_[SortEntry(order=HELPFULNESS, direction=DESCENDING), SortEntry(order=POSITIVE_FEEDBACK, direction=DESCENDING), SortEntry(order=SUBMISSION_TIME, direction=DESCENDING)]
  • clientName_omega
  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • CLOUD, getReviews, 5ms
  • REVIEWS, PRODUCT

What pressure are these thermocouples rated for?

Asked by: Ellie2022
Thank you for your inquiry Ellie2022. Unfortunately, the TJ36 series are not pressure rated.
Answered by: Application Engineer MC
Date published: 2024-05-19

Hi, What is the max temperature rating for the wire that connects the probe to the K-type connector? It looks like plastic shielding on the wire and I don't want to melt it.

Asked by: SLC1
Thank you for your inquiry. The max temperature the wire can handle is 260C (500F)
Answered by: AEMO
Date published: 2019-10-21

What length needs to be inserted into the process for an accurate reading with a 6inch probe?

Asked by: Peter00
Hi Peter, considering the thermocouple sensor is at the tip of the probe, it would be safe to assume 0.5-1 inch would be needed to get an accurate reading.
Answered by: AndrewA
Date published: 2020-09-14

Can these be attached to a 2.5mm jack for use with a wireless bbq style type thermometer?

Asked by: Schwonkhead
Hi Schwonkhead, If your thermometer accepts a type K thermocouple then possibly yes. You'll need to check the wireless thermometer input specifications. Best regards OMEGA
Answered by: AENwlk
Date published: 2022-12-01

Hello, Can this thermocouple be welded around section B? Also, is it able to withstand pressures to up to 500 psi? Thank you

Asked by: Appm
The B section is where the Thermocouple wire is attached to the extension wire and potted. A tack weld could probably be made with a minimal amount of heat being applied. Omega does not pressure rate the probes but they do get used often in elevated pressures as what your inquiry suggests. If you need a probe with a pressure rating then the only one Omega offers is the pipe plug probe series.
Answered by: ApplicationEngineerANB
Date published: 2024-02-02

Can I get this with a 10' lead?

Asked by: aric
Thank you for your inquiry. Yes we can make these as long as 50' using the CUSTOMIZE button.
Answered by: CB Engineer
Date published: 2020-07-26

I am looking for 2 stainless steel temperature probes to go into a 55 gallon drum that’s height  is 34 inches. I want to hook it to a controller to manage a heating blanket  to maintain a temperature between 68 to 75°F. What Would you recommend

Asked by: Deldoochy
This would need to be reviewed with a Temperature Engineer due to the complexity so please send an inquiry to temp@omega.com.
Answered by: ANB ENG
Date published: 2020-07-28

Question, What are the voltage outputs between 0 and the max reading

Asked by: Cummins2300
Thank you for your inquiry. The voltage output varies with different thermocouple types but it would be in mV. If you have any further questions, please email temp@dwyeromega.com or call 1-888-826-6342.
Answered by: NorwalkAE_SP
Date published: 2024-03-07
  • y_2026, m_9, d_7, h_9CST
  • bvseo_bulk, prod_bvqa, vn_bulk_3.0.48
  • cp_1, bvpage1
  • co_hasquestionsanswers, tq_14
  • loc_en_US, sid_TJ1-CAIN-IM15U-200-CC-XCIB-DUA, prod, sort_[SortEntry(order=NUM_ANSWERS, direction=DESCENDING)]
  • clientName_omega
  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • CLOUD, getContent, 38ms
  • QUESTIONS, PRODUCT
en-US
en
Save Configuration