Skip to search Skip to main content Skip to navigation

Need assistance? Call us: 1-800-663-4209

We noticed you are in , please visit your local site by clicking the below link for regional offers and support.

TJ36-GG

Rugged Thermocouple Transition Joint Probes with Fiberglass Insulated Cable

Models In Stock
  • Use of Fiberglass and Ceramic Insulation Allows the Transition Joint to be Used Up to 482°C (900°F)
  • 304 SS and Inconel 600
  • Additionnal Sheaths Available: 310 SS, 316 SS, 321 SS and Super OMEGACLAD™ XL
  • Manufactured Compacted Mineral Insulation Cable for Long Lasting, Drift-Free Performance in Harsh Conditions
TJ36-GG
From $ 90.83
Models In Stock
Rugged Thermocouple Transition Joint Probes with Fiberglass Insulated Cable TJ36-GG TJ36-GG
loading all models

Can't find the right model?

Use our custom configurator to fine tune your product

Product Overview
  • Number of Connectors N/A
  • Process Temperature, Max 900 °C
  • Process Temperature, Min 0 °C
  • Series ID TJ36-GG
  • Temperature Sensor Type Thermocouple

Supported Applications

The Omega TJ36 series consists of rugged thermocouple transition joint probes designed for temperature measurement in harsh conditions. These sensors feature a compact mineral-insulated cable construction with braided fiberglass insulation on the lead wire, providing durability and thermal protection.

Applications include environments requiring operation up to 482°C (900°F), enabled by the use of fiberglass and ceramic insulation materials within the probe assembly.

Operating Conditions & Performance

The series supports a measurement range from 260 °C (500 °F) to 1204 °C (2200 °F), with specific upper temperature guidelines varying by sheath material and diameter. The probes meet or exceed Special Limits of Error (SLE) and EN 60584-2 Tolerance Class 1 accuracy standards.

  • Process Temperature: Up to 482°C (900°F)
  • Accuracy: SLE (Special Limits of Error) and EN 60584-2 Tolerance Class 1
  • Sheath Diameters: 1.59 mm (1/16 in), 3.18 mm (1/8 in), 4.78 mm (3/16 in), and 6.35 mm (1/4 in)
  • Stem Length: Standard stem length is 152.4 mm (6 in) with a 38 mm (1.50 in) spring strain relief

The transition joint measures 27 mm (1.06 in). Overall probe lengths are available at 150 mm (6"), 300 mm (12"), and 450 mm (18"). The design incorporates a spring strain relief to prevent wire pinching.

Temperature Guidelines by Sheath Material

The maximum operating temperature varies based on the selected sheath material and diameter, as documented in the series specification table:

  • Type K (CHROMEGA®/ALOMEGA®) with 304 SS: Up to 899 °C (1650 °F)
  • Type K with Inconel® 600: Ranges from 921 °C (1690 °F) for 1.59 mm diameter up to 1149 °C (2100 °F) for larger diameters
  • Type K with Super OMEGACLAD® XL: Ranges from 1038 °C (1900 °F) up to 1204 °C (2200 °F)
  • Type J (IRON-CONSTANTAN) with 304 SS: Up to 721 °C (1330 °F)
  • Type T (COPPER-CONSTANTAN) with 304 SS: Up to 371 °C (700 °F)

Configuration Options

The TJ36 series is configurable across multiple parameters including thermocouple type, sheath material, junction configuration, and lead termination. The standard electrical connection features stripped lead terminations.

  • Thermocouple Types: Type K (CHROMEGA®/ALOMEGA®), Type J (IRON-CONSTANTAN), Type T (COPPER-CONSTANTAN)
  • Junction Configurations: Grounded, Exposed, or Ungrounded
  • Sheath Materials: 304 SS, Inconel® 600, and Super OMEGACLAD® XL are standard. Additional sheaths available include 310 SS, 316 SS, 321 SS, Hastelloy® X.
  • Connector Options: Optional M8/M12 connectors (male straight or right-angled) can be added to the model number for additional cost using suffixes "M8-S-M", "M12-S-M", "M8-R-M", or "M12-R-M".
  • Dual Element: Dual element configurations are available in specific variants (e.g., -DUAL).

The series is manufactured in the USA. The model number guide follows the format: TJ36-----CC.

Key Product Differences

Variants within the series differ primarily by thermocouple type, sheath material composition, and physical dimensions. The model number explicitly defines these distinctions:

  • Sheath Material Codes: CASS (304 SS), CAIN (Inconel® 600), CAXL (Super OMEGACLAD® XL)
  • Diameter Codes: 116 (1/16"), 18 (1/8"), 316 (3/16"), 14 (1/4")
  • Junction Type Indicators: G for Grounded, E for Exposed, U for Ungrounded

The series offers standard stripped lead terminations as the default configuration. Variants with M8 or M12 connectors are distinguished by specific suffixes added to the base model number.

Rated 5 out of 5 by from Does the job. The company i work for uses these for process controls they last a long time and are very reliable.
Date published: 2016-04-14
Rated 5 out of 5 by from Best Thermocouples money can buy! These thermocouples are very well made, and very reliable!
Date published: 2026-07-16
Rated 4 out of 5 by from My top choice for temperature sensors. Omega is a direct manufacturer of many temperature sensors used by other equipment manufacturers, and it's much cheaper to work with Omega when sourcing replacement sensors. Omega is always my top choice for temperature sensors.
Date published: 2026-05-18
Rated 5 out of 5 by from Furnace Mapping K Type Thermocouples for use to monitor furnace temperature. Worked as expected for the furnace to map and monitor thermal gradients.
Date published: 2026-04-27
Rated 5 out of 5 by from High quality High quality thermocouple that just works right out of the box
Date published: 2025-12-04
Rated 5 out of 5 by from Great quality These are great and last for over a decade in our application.
Date published: 2025-11-30
Rated 5 out of 5 by from Just what we needed The website was easy to follow and get to what I needed. The item was in stock and shipped promptly. As soon as it arrived, we installed it and put it to work. It got our heat treating oven back to work with minimum downtime.
Date published: 2025-11-21
Rated 5 out of 5 by from Great wood-fired kiln thermocouples We fire our wood kiln to cone 15 and really torture these thermocouples and they hold up well.
Date published: 2025-08-25
  • y_2026, m_8, d_10, h_10
  • bvseo_bulk, prod_bvrr, vn_bulk_3.0.48
  • cp_1, bvpage1
  • co_hasreviews, tv_0, tr_41
  • loc_en_US, sid_TJ120-CASS-116U-6-CC, prod, sort_[SortEntry(order=HELPFULNESS, direction=DESCENDING), SortEntry(order=POSITIVE_FEEDBACK, direction=DESCENDING), SortEntry(order=SUBMISSION_TIME, direction=DESCENDING)]
  • clientName_omega
  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • CLOUD, getReviews, 3ms
  • REVIEWS, PRODUCT

What pressure are these thermocouples rated for?

Asked by: Ellie2022
Thank you for your inquiry Ellie2022. To expand on my previous answer, the sealed metal sheath portion of probe is pressure rated for G or U junctions, but not for E since G and U can be used with a compression fitting. The TJ spring section is not pressure rated.
Answered by: Application Engineer MC
Date published: 2025-10-25

Hi, What is the max temperature rating for the wire that connects the probe to the K-type connector? It looks like plastic shielding on the wire and I don't want to melt it.

Asked by: SLC1
Thank you for your inquiry. The max temperature the wire can handle is 260C (500F)
Answered by: AEMO
Date published: 2019-10-21

What length needs to be inserted into the process for an accurate reading with a 6inch probe?

Asked by: Peter00
Hi Peter, considering the thermocouple sensor is at the tip of the probe, it would be safe to assume 0.5-1 inch would be needed to get an accurate reading.
Answered by: AndrewA
Date published: 2020-09-14

Can these be attached to a 2.5mm jack for use with a wireless bbq style type thermometer?

Asked by: Schwonkhead
Hi Schwonkhead, If your thermometer accepts a type K thermocouple then possibly yes. You'll need to check the wireless thermometer input specifications. Best regards OMEGA
Answered by: AENwlk
Date published: 2022-12-01

What is the output of this sensor? Voltage or resistance change? Thanks.

Asked by: Student
This sensor produces millivolt output however resistance also varies based on ohms law.
Answered by: Application Engineer RD
Date published: 2022-09-13

Hello, Can this thermocouple be welded around section B? Also, is it able to withstand pressures to up to 500 psi? Thank you

Asked by: Appm
The B section is where the Thermocouple wire is attached to the extension wire and potted. A tack weld could probably be made with a minimal amount of heat being applied. Omega does not pressure rate the probes but they do get used often in elevated pressures as what your inquiry suggests. If you need a probe with a pressure rating then the only one Omega offers is the pipe plug probe series.
Answered by: ApplicationEngineerANB
Date published: 2024-02-02

Can I get this with a 10' lead?

Asked by: aric
Thank you for your inquiry. Yes we can make these as long as 50' using the CUSTOMIZE button.
Answered by: CB Engineer
Date published: 2020-07-26

I am looking for 2 stainless steel temperature probes to go into a 55 gallon drum that’s height  is 34 inches. I want to hook it to a controller to manage a heating blanket  to maintain a temperature between 68 to 75°F. What Would you recommend

Asked by: Deldoochy
This would need to be reviewed with a Temperature Engineer due to the complexity so please send an inquiry to temp@omega.com.
Answered by: ANB ENG
Date published: 2020-07-28
  • y_2026, m_8, d_10, h_10CST
  • bvseo_bulk, prod_bvqa, vn_bulk_3.0.48
  • cp_1, bvpage1
  • co_hasquestionsanswers, tq_15
  • loc_en_US, sid_TJ120-CASS-116U-6-CC, prod, sort_[SortEntry(order=NUM_ANSWERS, direction=DESCENDING)]
  • clientName_omega
  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • CLOUD, getContent, 26ms
  • QUESTIONS, PRODUCT
en-US
en
Save Configuration