Skip to search Skip to main content Skip to navigation

1-800-663-4209 | Welcome to our new website, found an issue or bug? Please report it here

We noticed you are from . Visit your local site for regional offers and live support.

MFR0122-Humidistat

Relative Humidity Controller for Enclosures

MFR0122-Humidistat
From $ 170.37
Relative Humidity Controller for Enclosures MFR0122-Humidistat MFR0122-Humidistat
loading all models
Product Overview
  • Status Control false
  • Air Velocity, Max 50 ft/s
  • Applications Access and Parking Control Systems, Automatic Teller Machines(ATM’s), Display Panels, Electrical and Electronic Enclosures, Telecommunications Systems, Ticket Dispensers
  • Contact Resistance 10 MΩ
  • Contact Type Change-over
  • Electrical Connection Screw Terminal
  • Electrical Connection Note 3-pole terminal, 3 x AWG 14 max [2.5 mm² (0.1 in2 )]
  • Enclosure Ratings IP20
  • Form factor Benchtop
  • Height 67 mm
  • Hysteresis Approx. 4% RH @ 50% relative humidity
  • Length 38 mm
  • Mechanical Life 100,000 cycles
  • Mounting Clip for 35 mm (1.4") DIN rail (EN 50022)
  • Operating Temperature, Max 60 °C
  • Operating Temperature, Min 0 °C
  • Relative Humidity 35 to 95%
  • Storage Temperature, Max 80 °C
  • Storage Temperature, Min -20 °C
  • Supply Voltage 250 Vac
  • Switch Type 1 A SPDT
  • Switching Capacity, Max 5 A @ AC 230 V (resistive load) 1.0 A @ AC 230 V (inductive load at cos j = 0.8); DC 20 W
  • Switching Capacity, Min 100 mA @ AC/DC 20 V
  • Weight 60 g
  • Width 50 mm
  • Wire Gauge 14 AWG
  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • CLOUD, getReviews, 16ms
  • REVIEWS, PRODUCT
  • bvseo-msg: The resource to the URL or file is currently unavailable.;

Will the MFR0122 work to de-humidify ( turn on a make up air unit ) a wand-wash car wash bay? Do the contacts close on humidity rise? and switch on 24VAC?

Asked by: Humidor
Thank you for your inquiry. This product is designed to be installed in an enclosure to monitor the relative air humidity and control an electric heater to dehumidify the air within enclosure. It cannot be installed outdoors or in a location with direct exposure to water.
Answered by: Application Engineer JB
Date published: 2019-11-19
  • y_2025, m_6, d_3, h_11CST
  • bvseo_bulk, prod_bvqa, vn_bulk_3.0.42
  • cp_1, bvpage1
  • co_hasquestionsanswers, tq_1
  • loc_en_US, sid_MFR0122, prod, sort_[SortEntry(order=NUM_ANSWERS, direction=DESCENDING)]
  • clientName_omega
  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • CLOUD, getContent, 51ms
  • QUESTIONS, PRODUCT
en-US
en
Save Configuration