Skip to search Skip to main content Skip to navigation

Need assistance? Call us: 1-800-663-4209

We noticed you are in , please visit your local site by clicking the below link for regional offers and support.

Series-DRN4

PWM/Analog/Floating Point to Resistance Output Interface Device

  • Converts control signals to resistance output: DRN3.1 modules accept analog, pulse, floating point, and triac inputs and convert them into a proportional resistive output.
  • Ideal for legacy control upgrades: Directly replaces variable resistance controllers by simulating a slide wire or rotary potentiometer.
  • Flexible input compatibility: Supports 0-5 VDC, 0-10 VDC, 0-15 VDC, 0-20 mA, 4-20 mA, pulse, and floating point control signals.
  • Multiple resistance network options: Available resistor networks include 0-135 Ω, 0-270 Ω, 0-500 Ω, 0-1K Ω, 0-10K Ω, 0-15K Ω, and 0-20K Ω ranges.
  • Reliable fail-back operation: On-board fail-back relays allow the circuit to revert to the original controller signal if supply power is lost.
  • Built for actuator and sensor simulation: Well suited for electronic potentiometer applications, electric actuator control, and resistive sensor simulation.
  • No-wrap output protection: The resistance output stops at the selected minimum or maximum value instead of wrapping around, helping maintain predictable control.
  • Panel-friendly design: Compact snaptrack mounting, captive screw terminals, and optional DIN rail adapter support clean control-panel installation.
  • Durable interface performance: Form C relays, 256-step output resolution, RoHS2/WEEE compliance, and ACI’s two-year limited warranty provide dependable long-term use.
Series-DRN4
From $ 457.00
PWM/Analog/Floating Point to Resistance Output Interface Device Series-DRN4 Series-DRN4
loading all models
Product Overview
  • Approvals RoHS2, WEEE
  • Digital Output Note Digital Output Type: Form “C” Relays
  • Electrical Life 100,000 operation @ 1A
  • Height 1 in
  • Input Current 4 to 20 mA, 0 to 20 mA
  • Input Note Floating Point / Tri-State Input Signal Source: Relay, Contact Closure, Transistor, or Triac (Adapter Required); Floating Point / Tri-State Rates of Change: 55 seconds for full output span; Floating Point / Tri-State Input Signal Trigger Level: 5-24 VDC/VAC
  • Input Type Analog
  • Input Voltage Note 0 to 5 VDC
  • Length 2.4 in
  • Materials PVC
  • Mechanical Life 10 million operations
  • Mounting Mounts directly to ½” knockout on actuator housing
  • Operating Humidity 10 to 95% RH, non-condensing
  • Operating Temperature, Max 120 °F
  • Operating Temperature, Min 35 °F
  • Output Resistance 0 to 135 Ω
  • Pulse Input Note Input Pulse Signal Source: Relay Contact Closure, Transistor, Triac (Adapter Required); Input Pulse Signal Trigger Level: 5-24 VDC/VAC; O Time Between Pulses: 80 milliseconds
  • Pulse Measurement Range 55 sec
  • Resolution 32 steps
  • Series ID Series-DRN4
  • Storage Temperature, Max 150 °F
  • Storage Temperature, Min -20 °F
  • Supply Current 130 mA
  • Supply Voltage 24 Vac/Vdc
  • Switch Rating 1 A @ 30 Vdc / 125 Vac
  • Weight 0.43 lb
  • Width 3.8 in
  • Wire Gauge 18 AWG

Supported Applications

The ACI Series DRN4 is a resistive output motor actuator interface designed to accept various DDC system signals. The device functions as an electronic potentiometer, electric actuator control, and for resistive sensor simulation or motor pot replacement applications.

  • Electronic potentiometer
  • Electric Actuator control
  • Resistive Sensor Simulation
  • Motor Pot Replacement

Operating Conditions & Performance

The Series DRN4 operates within an ambient temperature range of 35 to 120°F (1.7 to 48.9°C) and a humidity range of 10 to 95% non-condensing. Storage is supported from -20 to 150°F (-28.9 to 65.5°C). The unit provides a resistive output of 0 to 135Ω (3 watts) with a resolution of 32 steps.

  • Supply Voltage: 24 VAC or 24 VDC, +/-10%
  • Supply Current: 130 mA maximum
  • Floating Point / Tri-State Rates of Change: 55 seconds for full output span

Configuration Options

The Series DRN4 accepts multiple input signal types field selectable by an 8-position DIP switch. The enclosure is constructed from Polyvinyl Chloride (PVC) with a UL94 V-0 flammability rating and mounts directly to a ½" knockout on the actuator housing.

Input Signal Configurations

  • Voltage: 0 to 5 VDC, 1 to 5 VDC, 0 to 10 VDC, or 2 to 10 VDC @ 100,000Ω
  • Current: 0-20 mA or 4 to 20 mA @ 250Ω
  • Pulse Source: Relay Contact Closure, Transistor, or Triac (Adapter Required)
  • Floating Point / Tri-State Input: Accepts two digital signals for increase and decrease; source includes Relay, Contact Closure, Transistor, or Triac (Adapter Required)

Outputs & Connections

  • Digital Output Type: Form "C" Relays with a contact rating of 1A @ 30 VDC / 125 VAC
  • Relay Electrical Life: 100,000 operation @ 1A; Mechanical Life: 10,000,000 operations
  • Electrical Connection: Color coded 18 AWG wire leads with spade connectors

Pulse Ranges by Model Version

  • DRN4 (Firmware 08000002.OBJ): 0.59 - 2.93s, 0.02 - 5.0s, or 0.1 - 25.5s
  • DRN4 VERSION #2 (Solidyne Firmware 08000101.OBJ): 0.023-6.0s

Key Product Differences

The series includes two primary variants distinguished by firmware and pulse range capabilities:

  • DRN4 (Item # 127200): Standard version supporting multiple selectable pulse ranges.
  • DRN4 VERSION #2 (Item # 127200): Configured for Solidyne applications with a specific pulse range of 0.023-6.0s.

Certain input configurations require accessories ordered separately, such as the Triac Adapter Kit or Transient Voltage Suppressor (ACI Part: 142583). A 1K Ohm 1/2 Watt resistor is included with all DRN4 units for Johnson Control triac inputs. The override button function does not operate in 1-5V or 0-5V settings.

  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • CLOUD, getReviews, 6ms
  • REVIEWS, PRODUCT
  • bvseo-msg: The resource to the URL or file is currently unavailable.;
  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • CLOUD, getContent, 7ms
  • QUESTIONS, PRODUCT
  • bvseo-msg: The resource to the URL or file is currently unavailable.;
en-US
en
Save Configuration