Need assistance? Call us: 1-800-663-4209
HHF143-Series
Precision Handheld Rotating Metal Vane Thermo-Anemometer Kit
- High Accuracy (± 1.0% of Reading)
- Low Speed Sensitivity
- Wide Temperature Range -20 to 100°C (-4 to 212°F)
- Temperature Measurement Option
HHF143-Series
From
$
1,720.42
Product Overview
- Accuracy ± 1 %
- Accuracy Detail ± 1.0% of reading ± 1-digit
- Additional Features 1 Volume Calculation, Temperature
- Battery life 150 hr
- Battery Size and Type Alkaline AA
- Cable Length 5 ft
- Certifications NIST Traceable Calibration
- Display Type Backlit LCD
- Enclosure Temperature, Max 50 °C
- Enclosure Temperature, Min 0 °C
- Form factor Handheld
- Height 6.5 in
- Length 3.25 in
- Number of Digits 4
- Process Temperature, Max 100 °C
- Process Temperature, Min -20 °C
- Resolution 1 FPM
- Series ID HHF143-Series
- Supply Power Note 150 hours Appx
- Temperature Accuracy ± 0.3 °C
- Temperature Sensor Type Thermocouple Type K or Thermistor
- Width 1.5 in
Supported Applications
The Omega HHF143 Series is a precision handheld rotating metal vane thermo-anemometer kit designed for measuring air velocity and temperature. Documented applications include indoor air quality, process control, flow hood monitoring, HVAC systems, aerospace development, industrial process airflow, and fluids research.
Operating Conditions & Performance
The series measures air velocity across two primary ranges depending on the probe size: 0.2 to 40.00 MPS (40 to 7800 FPM) for the HHF143B model and 1.5 to 35.00 MPS (300 to 6800 FPM) for the HHF143A model. Temperature measurement capability spans -20 to 100°C (-4 to 212°F). Accuracy is specified as ±1.0% of reading ±1-digit for air velocity and ±0.3°C + 0.2% of reading in °C for temperature.
Resolution is provided at 0.01 MPS or 1 FPM for air velocity, and 0.1°C or °F for temperature. The instrument features a response time of less than 1 second according to the manual documentation. Ambient operating conditions are rated from -40 to 50°C (-40 to 122°F), with storage temperatures supported between -40 to 70°C (-40 to 158°F). The device is designed for use in air and clean gases, capable of handling airstreams with varying humidity levels up to 95% RH non-condensing.
Key Performance Specifications
- Air Velocity Ranges: HHF143A: 0.2 to 40.00 MPS (40 to 7800 FPM); HHF143B: 1.5 to 35.00 MPS (300 to 6800 FPM)
- Temperature Range: -20 to 100°C (-4 to 212°F) using either air velocity probe head
- Air Velocity Accuracy: ±1.0% of reading ±1-digit
- Temperature Accuracy: ±0.3°C + 0.2% of reading in °C (example: ±0.5°F @ 68°F)
- Ambient Operating Temperature: -40 to 50°C (-40 to 122°F) per manual; 0 to 50°C (32 to 125°F) per data sheet
- Humidity Rating: Up to 95% RH non-condensing
Configuration Options
The HHF143 Series is configurable by probe diameter and optional output interfaces. The series supports two standard probe sizes: a 25 mm (1") vane for the HHF143A model and a 70 mm (2¾") vane for the HHF143B model. Wetted materials include stainless steel and nickel-plated brass.
Output options allow integration with external systems or data logging:
- Analog Voltage Output: Available as a 0 to 5 Vdc voltage output (add suffix "-V" to model number)
- Digital Communication: USB interface available via the "-USB" suffix
- Other Outputs: The manual references RS-232 and 4–20 mA outputs as optional configurations, though specific ordering codes for these are detailed in the model number guide.
The instrument is powered by three "AA" alkaline batteries (included). Additional accessories include a protective boot (add suffix "-PB"), replacement probe heads with temperature sensors and cables, and custom cable lengths. The kit includes extension rods (flexible, straight, and with handle) and comes complete with an NIST calibration certificate.
Key Product Differences
The series distinguishes between two primary model families based on probe diameter:
- HHF143A: Handheld thermo-anemometer equipped with a 25 mm (1") dia probe.
- HHF143B: Handheld thermo-anemometer equipped with a 70 mm (2¾") dia probe.
Variations are further defined by optional suffixes added to the base model number. The "-V" suffix denotes units configured for 0 to 5 Vdc voltage output, while the "-USB" suffix indicates inclusion of USB communications capabilities. A protective boot is available as an add-on option denoted by the "-PB" suffix.
Replacement parts are offered separately, including specific probe heads (HHF140A-RP-T for 25 mm and HHF140B-RP-T for 70 mm) which include temperature sensors. The series complies with CE, UKCA, RoHS standards, and includes NIST calibration.
PDFs & Manuals
Accessories
sensors
Show Ratings & Reviews