Skip to search Skip to main content Skip to navigation

1-800-663-4209 | Welcome to our new website, found an issue or bug? Please report it here

We noticed you are in , please visit your local site by clicking the below link for regional offers and support.

KW350

Item# KW350

In Stock

Lead Time (If not in stock): 0 week

Product Specs

<< See all Product Models
Brand
Accuracy 0.5 Class
Applications Building and Maintenance, Control Panel, Environmental Monitoring, Industrial and Manufacturing
Approvals BTL Certified, CE, UKCA, RoHS2, cULus Listed (File # E359521), Glow Wire Test (IEC 695-2-1) 960 °C, Halogen free (DIN/VDE 0472, Part 815)
Connection Note DIN rail mounted pre-labeled terminal blocks for voltage and CT connections pre-installed
Data Format 8 data bits:no parity:1 stop bit
Display Type LCD
Enclosure Material Flame retardant polycarbonate
Enclosure Ratings IP67, UL Type 12, UL Type 13, UL Type 4, UL Type 4X, UL Type 6, UL Type 6p
Frequency 50/60 Hz
Fuse Rating 600 VAC/2A
Height 7.01 in
Input_Current Note 150% of current sensor rating (mV CT’s) to maintain accuracy. Up to 6000 Amps w/ Rogowski Coils
Insulation Note Electrical Insulation: Totally Insulated
Isolation 2000 Vac
Length 11.81 in
Load Current, Max 5 A
Load Voltage, Max 30 V
Measurement Type Single Phase, 3 Phase – Four Wire (WYE), 3 Phase – Three Wire (Delta)
Mounting IEC 35mm DIN Rail (Standard)
Network and Communications BACnet Device Instance Number: 1 (Default); Field adjustable from 1 to 4194303; ; Max Station: 127 MS/TP Masters (MAC Addresses is 0 to 127)
Number of Channels Note Voltage Channels: 400 Volts AC (L-N), 690 VAC (L-L), 50/60 Hz
Number of Inputs 3
Operating Distance, Max 1200 m
Operating Humidity 5 to 95% RH, non-condensing
Operating Temperature, Max 158 °F
Operating Temperature, Min -13 °F
Output Detail Pulse Output: Two-wire pulse train, Isolation Voltage 2500 VAC, 5~60 VDC Load Voltage, 10 mA Max Load Current, Pulse Width 20~100ms, Pulse Constant 1~60,000
Relay Output 250 Vac
Sampling Rate 3.84kHz @ 60 Hz; 3.2kHz @ 50 Hz
Security Password Protected to access Settings. Sealed and Tamper Proof Cover.
Series ID KW350
Software AcuRev 1310 Utility Software, Windows Based; (USB-RS485 converter is required to connect to computer)
Storage Temperature, Max 185 °F
Storage Temperature, Min -40 °F
Supply Power Note Energy Pulse Power Supply: External 24 VDC Power Supply (Required) Note: 1K Ohm External Current Limiting Resistor (Recommended)
Supply Voltage 100 to 415 Vac, 100 to 300 Vdc
Termination 120 to 300 Ω
Update Rate Accumulated Parameter Update Rate: 1 sec ; Real Time Parameter Update Rate: 200 ms
Voltage Measurement Range 100 to 400 Vac (L-N), 100 to 690 Vac (L-L)
Weight 3.8 lb
Width 11.81 in
Wire Gauge 22 to 14 AWG
See All Specs Show Less
Power Meter KW350 KW350
  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • CLOUD, getReviews, 4ms
  • REVIEWS, PRODUCT
  • bvseo-msg: The resource to the URL or file is currently unavailable.;
en-US
en
Save Configuration