Product Specs

<< See all Product Models
Brand
Accuracy 0.5 Class
Applications Building and Maintenance, Control Panel, Environmental Monitoring, Industrial and Manufacturing, Refrigeration Equipment
Approvals UL 508A, EN62208
Baud Rate 1200 to 115200
Compliance Note UL 746C 5-inch flame test
Connection Note DIN rail mounted pre-labeled terminal blocks for voltage connection pre-installed
Control Output Alarm
Data Format 8 data bits:no parity:1 stop bit
Data Interface Note RS-485 Serial, Dual Ethernet (KW1850-P1-D-W Only), Wireless Network Card (KW1850-P1-D-W Only)
Display Type LCD
Enclosure Material Flame retardant polycarbonate
Enclosure Ratings IP66, NEMA Type 4X
Frequency 45/65Hz
Frequency Note Pulse Frequency (MAX):100Hz, 50% Duty Cycle
Fuse Rating 600 VAC/2A
Height 7.01 in
Impedance Input 2MΩ/Phase
Inductive Loads <0.2VA
Input Control Signal 15 to 30 Vdc
Input Current 2 mA
Input Note Digital Inputs / Type: 18 Digital Inputs for Water and Gas Metering Pulse Counting / Dry Node; Acceptable CT Inputs: 333mV or Rogowski Coil (cannot mix CT’s);
Isolation 4000 Vac
Length 11.81 in
Load Current, Max 3 A
Load Voltage, Max 30 V
Materials Polycarbonate
Measurement Type Single Phase, 3 Phase – Four Wire (WYE), 3 Phase – Three Wire (Delta)
Mounting ANSI C39.1 (4" Round) or an IEC 92mm DIN (Square) form; IEC 35mm DIN Standard
Network and Communications Modbus Address Range:1 to 247 (The default is 1)
Number of Inputs 18
Operating Distance, Max 1200 m
Operating Humidity 5 to 95% RH, non-condensing
Operating Temperature, Max 158 °F
Operating Temperature, Min -13 °F
Output Detail Ten limit alarms configured for peak demand, current, or power quality; Auxiliary Power Output: 15VDC, 1W; Pulse Output: Two-wire pulse train, Isolation Voltage 2500VAC, 0-30 VDC Load Voltage, 10mA Max Load Current, Pulse Width 20~100ms (80ms Default), Pulse Constant 1~60,000 (50000 Default) IMP/kWh
Power Consumption 5 W
Relay Output 250 Vac
Response Time 2 ms
Security Password Protected to access Settings. Sealed and Tamper Proof Cover
Series ID KW1850
Software Accuview Utility Software, Windows Based. USB-RS485 converter is required to connect to computer for KW1850-P1-D-S only
Storage Temperature, Max 185 °F
Storage Temperature, Min -40 °F
Supply Voltage 100 to 415 Vac, 100 to 300 Vdc
Volt-Amperes Burden <0.2VA
Voltage Measurement Range 100 to 400 Vac (L-N), 100 to 690 Vac (L-L), 100 to 400 Vac rms (1 phase)
Weight 8 lb
Width 11.81 in
Wire Gauge 22 to 16 AWG
Working Life Multi-Tariff Time of Use (TOU): 4 tariffs (sharp, peak, normal, valley), 14 schedules, 14 segments, weekends and 10-year holiday settings
See All Specs Show Less