Product Overview
  • Accuracy Class A
  • Accuracy Detail Class A (± 0.15+.002*
  • Insulation Resistance >50 MΩ @ 50 Vdc
  • Insulation Resistance Note Greater than 50 Megohms at 50 Vdc. at 25°C (77°F)
  • Lead Material Nickle Plated Copper
  • Long Term Stability 0.05°C (0.02% of resistance) per 5 years, -50 to 300°C, 0.25°C per year to 540°C
  • Self Heating Effect >15 mW/°C
  • Sensing Element RTD
  • Series ID RTDCAP
  • Temperature Sensor Type RTD
  • Wire Gauge 28 AWG

Supported Applications

The Omega RTDCAP Series Platinum RTD Capsules are ready-to-use sensors designed for reliable rugged embedment, insertion, or probe assembly. These encapsulated elements feature insulated lead wires welded and anchored internally to provide a compact sensing solution.

Operating Conditions & Performance

The series utilizes International grade thin film platinum sensing elements with an alpha coefficient of 0.00385 Ω/Ω/°C per IEC 60751. Interchangeability and accuracy are rated Class A (±0.15+0.002*|t|°C) between -50 and 300°C, with Class B accuracy above and below these temperatures.

Operating temperature ranges vary by lead material:

  • -200 to 260°C (-320 to 500°F) for TFE leads
  • -200 to 350°C (-320 to 660°F) for Polyimide leads
  • -75 to 510°C (-100 to 950°F) for Fiberglass leads
  • -50 to 200°C (-60 to 390°F) for Moisture Resistant models

Standard sensors and encapsulation materials are rated up to 540°C (1000°F). Time constants in water at 3/Second range from 0.5 seconds for the 0.086 diameter capsule to 1.5 seconds for the 0.187 diameter.

Configuration Options

The RTDCAP series is configurable across resistance, wire count, dimensions, and materials:

  • Sensing Element Resistance: Available in 100 Ω or 1 kΩ (Ice Point: 100.00±0.06Ω or 1000.0±0.6Ω at 0°C).
  • Wire Configurations: Offered in 2-, 3-, or 4-wire configurations.
  • Diameters and Lengths: Tip diameters range from 0.086 to 0.125 inches with standard lead lengths of 1 m (40").
  • Housing Materials: Alumina, Polyimide, or Fiberglass encapsulation.
  • Lead Insulations: Nickel-Coated Copper insulated with 28 AWG Fiberglass, TFE, or Polyimide.
  • Special Options: Moisture-resistant models feature a 300 psi seal and are available in specific configurations.

Electrical connections consist of insulated lead wires welded and anchored internally. The series supports self-heating applications with maximum currents of 5 mA for 100 Ω elements and 2 mA for 1 kΩ elements, while recommended current for temperature sensing is 1 mA maximum.

Key Product Differences

Variants within the RTDCAP series are distinguished by their specific combination of resistance value (100A vs. 1KA), wire count (indicated in model codes as -1-, -2-, or -3- for 2, 3, and 4-wire respectively), capsule diameter (e.g., A086, P098, A125), lead material type (K for Polyimide/Kapton®, T for TFE/PTFE, F for Fiberglass), and length code. Note that 3- and 4-wire sensors can be modified by the customer for 2- and 3-wire applications by cutting off unneeded lead wires.

  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • CLOUD, getReviews, 4ms
  • REVIEWS, PRODUCT
  • bvseo-msg: The resource to the URL or file is currently unavailable.;

Can I trim the leads short without negatively affecting the performance?

Asked by: MattK
Trimming the leads shorter will not affect the RTD's performance.
Answered by: ApplicationEngineerANB
Date published: 2020-04-23

Does it matter what method I use to terminate these?

Asked by: MattK
The RTDCAP series would be terminated in an uncompensated three terminal connector if the lead needs to be extended. It also can be directly connected to the screw terminals on instruments accepting RTD's.
Answered by: ApplicationEngineerANB
Date published: 2020-04-23

Hi, Would this be suitable to insert this inside a plastic pipe in which water is flowing to measure the temperature of water? I mean is immersing it inside a flowing water ok?

Asked by: Nima1994
Thank you for the inquiry. These are not suitable for immersion applications. Please consider the following for this type of application. https://www.omega.com/en-us/temperature-measurement/temperature-wire-sensors/hsrtd/p/HSRTD-3-100-1-10-3M Best regards, OMEGA
Answered by: NorwalkAE_RS
Date published: 2024-07-19

What is the recommended minimun hole size for thr probe in steel(0.098"Ø or any other for that matter)? Is thermal paste rcommended? In oilly conditions, sealing off seneor with high temp RTV recommened?

Asked by: LeadTech
The hole should be drilled so the sensor can be easily be inserted and removed and Thermal paste will enhance the Heat transfer. Make sure the pastes temperature rating is acceptable for the application. Using High Temperature RTV is okay as well to keep oil from seeping in to the drilled out cavity.
Answered by: Application Engineer AB
Date published: 2021-06-08

I temperature sensing in robot end of arm tooling. Is there high flex cable available for RTDs or can I use any cable?

Asked by: MattK
Thank you for your interest in our product We do not have a high flex RTD cable. Repeated cable flexing will cause wire breakage
Answered by: SAT_SAE
Date published: 2020-04-24
  • y_2026, m_8, d_8, h_9CST
  • bvseo_bulk, prod_bvqa, vn_bulk_3.0.48
  • cp_1, bvpage1
  • co_hasquestionsanswers, tq_5
  • loc_en_US, sid_RTDCAP-100A-1-A086-060-K-40, prod, sort_[SortEntry(order=NUM_ANSWERS, direction=DESCENDING)]
  • clientName_omega
  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • CLOUD, getContent, 25ms
  • QUESTIONS, PRODUCT
en-US
en
Save Configuration