Need assistance? Call us: 1-800-663-4209
Series-PFT
Paddlewheel Flowmeters for Liquid Monitoring, Brass/316 SS, 4-20 mA Output
- Long product life even in applications with particulate due to bearings and shaft that offer excellent wear protection
- Use in irrigation applications with weatherproof and submersible ratings
- Save time and inventory with one unit that is adjustable over a large pipe size range
- Application versatility with a variety of wetted material selections
- Reduce need for additional external components with integral 4-20 mA output
- Eliminate concerns regarding magnetic material in flow due to sensor technology, which uses inductive sensing and no magnets
Can't find the right model?
Use our custom configurator to fine tune your product
Product Overview
- Electrical Connection Cable
- Enclosure Ratings IP67
- Linear Flow Rate, Max 25 ft/s
- Linear Flow Rate, Min 1.2 ft/s
- Linearity ± 1.0%
- Operating Temperature, Max 212 °F
- Operating Temperature, Min -40 °F
- Power Consumption 40 mA
- Pressure Limits Up to 400 psi
- Pressure Limits Note (27.6 bar) @ 100°F (37.8°C), 325 psig (22.4 bar) @ 212°F (100°C).
- Process Connection Size 1 1/2 in
- Repeatability ± 0.5%
- Series ID Series-PFT
- Supply Power Type DC
- Supply Voltage 10 to 35 Vdc
- Weight 3 lb
- Wire Gauge 22 AWG
Supported Applications
The Dwyer Series PFT is an insertion paddlewheel flow sensor designed to monitor liquid flow rates in pipes ranging from 1-1/2 to 40˝ (38.1 to 1016 mm). The series utilizes a single size-adjustable sensor with inductive, non-magnetic sensing of impeller blades, enabling low-flow rate monitoring and eliminating concerns regarding magnetic material in the process media. Documented service is specified for water-based fluids.
Operating Conditions & Performance
The Series PFT operates within a flow velocity range of 1.2 to 25 ft/s (0.37 to 7.62 m/s). Process temperature limits are -40 to 212°F (-40 to 100°C), with pressure ratings of 400 psig (27.6 bar) @ 100°F (37.8°C) and 325 psig (22.4 bar) @ 212°F (100°C). Performance specifications include linearity of ±1.0% of full range and repeatability of ±0.5% of full range.
Installation requirements specify mounting the sensor at an angle between 30° to 150° off vertical on horizontal runs, with a straight run of at least 10 pipe diameters upstream and 5 pipe diameters downstream. The impeller shaft must be located 10% inside the pipe ID.
Configuration Options
The series offers configurable options across mounting styles, body materials, output signals, wetted parts, and electrical connections to accommodate specific installation needs.
- Housing & Body Materials: Brass or 316 SS. Enclosure rating is NEMA 6P (IP67); brass units are IP67 only.
- Mounting Styles: Insertion and hot-tap insertion styles are available. Process connections include standard 1-1/2˝ male NPT or BSPT, with optional 2˝ male NPT or BSPT. Isolation valve options are selectable for the 1-1/2˝ connection.
- Output Signals:
- Pulse: NPN open collector square wave output rated 60 V @ 50 mA maximum; frequency range 3.2 to 200 Hz with a pulse width of 2.5 msec ±25%.
- Analog: 4-20 mA linear transmitter where 4 mA equals 0 ft/s and 20 mA equals 25 ft/s.
- Two-wire pulse option available (600 μA / 40 mA configuration).
- Wetted Materials: Impeller is 316 SS. Shaft options include Tungsten carbide standard or 316 SS optional. Bearings are PTFE standard.
- O-Ring Options: FKM fluoroelastomer (standard), Silicone (FDA approved), or Buna-N.
- Electrical Connection: Standard cable is 22 AWG shielded UL type PTLC rated 105°C, 20´ (6.1 m) long with a cable gland; extendable up to 2000´ (609 m). An optional UL listed burial-rated cable (18 GA, 4 ft / 1.2 m) is available.
- Approvals: CE certified per CENELEC EN 55011: 2006, CENELEC EN 61326-1: 2006, IEC 61000-4 series standards (2 through 6), and the 2004/108/EC EMC Directive.
Key Product Differences
The Series PFT model number structure defines specific configurations. The style code distinguishes between Insertion ('I') and Hot-tap insertion ('H'). Output codes differentiate the 600UA/40 MA pulse output ('D') from the Analog 4-20 mA transmitter ('A'). Body material is designated as Brass ('B') or 316 SST ('S'). Mounting options range from standard NPT and BSPT threads to hot-tap configurations with or without valves. Wetted material codes specify either a Tungsten-carbide shaft/316 SS impeller combination (code '1') or an all-316 SS shaft and impeller configuration (code '2'). Electrical connection options include the standard shielded wire ('S') or burial-rated cable ('B'). A stainless steel tag option is available as a suffix.
PDFs & Manuals
Accessories
installation hardware