Skip to search Skip to main content Skip to navigation

1-800-663-4209 | Welcome to our new website, found an issue or bug? Please report it here

We noticed you are in , please visit your local site by clicking the below link for regional offers and support.

Series-CLT

4-20 mA Continuous Level Transmitter, 316 SS, 72 in, for Gas/Oil Use

  • Loop-powered 4–20 mA or voltage output provides continuous liquid level monitoring
  • Configurable up to 72 in (183 cm) for tanks requiring full-range level indication
  • 316 SS or Buna-N float options match pressure, fluid type, and chemical compatibility
  • Rated to 300 psi and 230 °F with vertical mount and sealed junction-box connection
Series-CLT
From $ 0.00
4-20 mA Continuous Level Transmitter, 316 SS, 72 in, for Gas/Oil Use Series-CLT Series-CLT
loading all models

Can't find the right model?

Use our custom configurator to fine tune your product

Product Overview

The Series CLT Continuous Level Transmitter is engineered for precision, custom-configured tank level monitoring in industrial applications including oil & gas, hydrocarbon storage, low-specific-gravity fluids, chemical feed, and general liquid storage. With selectable outputs (4-20 mA current or proportional voltage) and broad material options, it adapts to demanding installations requiring continuous rather than discrete high/low switching.

At the heart of the CLT is a float-and-reed-switch assembly contained within a sealed hollow stem. As the float ascends or descends with liquid level, it actuates reed switches which, in conjunction with a resistor network, provide a voltage or current output proportional to the level reading. 

Installation is straightforward: the unit can be supplied in lengths up to 72″ overall (with up to 68″ indication length), with user-specified distances from bottom mount to float stop, and float spacing to suit tank geometry. Available in either ½″ NPT, 1-1/4″ NPT, 2″ NPT or 3″ 150# flange mounting (depending on construction) to match process connections. 

Material options allow tailoring for fluid type and system condition: Choose stems/floats in 316 stainless steel for higher pressure or corrosive media (up to 300 psig), or Buna-N floats with brass stems for less demanding services (up to 150 psig). Temperature ratings likewise vary with material: e.g., Buna-N float water service up to 180 °F, or with oil service -40 °F to 230 °F. 

Electrical interface is user-friendly: current output units require 10-40 VDC and feature a junction box rated NEMA 4 (IP56). Voltage output models require 10-30 VDC and provide free leads. Loop resistance is rated up to 1.4 kΩ. 

Whether monitoring fluid levels in storage tanks, fuel oil sumps, hydraulic reservoirs or chemical process vessels, the CLT’s continuous output delivers actionable real-time data for control systems, alarms or records. Its flexible configuration, robust construction and industrial credentials make it a strong choice where full-range liquid level indication is needed instead of only high/low detection.

  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • CLOUD, getReviews, 4ms
  • REVIEWS, PRODUCT
  • bvseo-msg: The resource to the URL or file is currently unavailable.;
  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • CLOUD, getContent, 14ms
  • QUESTIONS, PRODUCT
  • bvseo-msg: The resource to the URL or file is currently unavailable.;
EXAMPLE CLT V S 5 F3 20.25 02.00 25.75 Series CLT-VS5F3-20.25-02.00-25.75 Continuous Level Transmitter, voltage output, 316SS, 3" 150# SS flange, 316SS float, 20.25" indication length, 2.00" distance from bottom of mounting connection to upper float stop, 27.75" overall length.
CONSTRUCTION CLT               Continuous Level Transmitter
OUTPUT   V
C
            Voltage, proportional signal of 0 to supply voltage
4-20 mA (Junction box provided)
STEM AND
CONNECTION MATERIAL
    B
S
          Brass with Beryllium copper stops
316 SS with SS ARMCO PH-15-7MO stops
CONNECTION TYPE       1
2
3
4
5
        1/2" NPT
1-1/4" NPT
2" NPT
3" 150# Flange, carbon steel (max. press. 150 psi [10.3 bar])
3" 150# Flange, 316 SS (max. press. 150 psi [10.3 bar])
FLOAT TYPE                 Material Min. s.g. Max. Press. psi (bar) Float Factor in (mm)
        F1
F2
F3
      Buna-N
Buna-N
316 SS
0.55
0.55
0.75
150 (10.3)
150 (10.3)
300 (20.7)
2.0 (50.8)
2.5 (63.5)
3.5 (52.4)
INDICATION LENGTH           00.00     Length that the unit sends an output for level. Maximum is 68" (173 cm)
TOP FLOAT STOP
"C" DIMENSION
            00.00   Distance from bottom of mounting connection to upper float stop. Minimum is 1/4" (6.4 mm)
OVERALL LENGTH "B"               00.00 To calculate overall length, add indication length, top float stop dimension "C", and float factor. Maximum length is 72" (1.82 m)
en-US
en
Save Configuration