Need assistance? Call us: 1-800-663-4209
Series-3100MP
3100MP Smart Pressure Transmitter for Flow/Level, HART, Hazardous Locations
Models In Stock
- Completely configurable using zero/span button (no calibrator required)
- Rangeability (100:1)
- Multiplanar
- Fits standard manifold valves
- Automatic sensor temperature compensation
- Easy installation
Series-3100MP
From
$
2,932.40
Models In Stock
Can't find the right model?
Use our custom configurator to fine tune your product
Product Overview
- Accuracy ± 0.075 %
- Accuracy Detail ± 0.075% FS (@ 20°C)
- Burst Pressure 10,000 psi Maximum
- Compliance Note CE, FM, ATEX option available (consult factory)
- Damping Time 0.25 to 60 s
- Electrical Connection 1/2 in NPT female Conduit with Screw Terminal block
- Electrical Output 4 to 20 mA, HART
- Enclosure Ratings Hazardous Location Rated, IP66, NEMA Type 4X
- Long Term Stability ± 0.125% FSO/year
- Loop Resistance Operation: 0 to 1500 Ω, HART® Communication: 250 to 500 Ω
- Materials, Wetted 316 Stainless Steel
- Media Compatibility Fuel gases, HVAC / room air, Inert / non-reactive gases, Steam, Hydrogen, Nitrogen, Oxygen
- Output Detail HART® Communication
- Output Signal Current, HART
- Measurement Pressure Type Differential
- Process Connection Size 1/4 in
- Process Connection Type NPT Female
- Process Temperature, Max 120 °C
- Process Temperature, Min -40 °C
- Response Time 0.12 s
- Series ID Series-3100MP
- Supply Power Type DC
- Supply Voltage 11.9 to 45 Vdc
- Thermal Effects ± 0.125% span/32°C
- Weight 3.9 kg
Supported Applications
The Dwyer Mercoid® Series 3100 is a microprocessor-based smart differential pressure transmitter optimized for draft measurement, flow, and level applications. The series features digital communication capabilities allowing configuration via push buttons or HART® Communication using a host, handheld communicator (HHT), or PC Configurator.
Documented application contexts include:
- Draft measurement
- Flow monitoring
- Level applications
- Hazardous locations requiring explosion-proof ratings for Class I, Div I, Groups A, B, C and D
The transmitter is compatible with gases, steam, liquids, or vapors.
Operating Conditions & Performance
The Series 3100 utilizes a capacitance sensor with software compensation for thermal effects. Key performance specifications include:
- Accuracy: ±0.075% FS (@ 20°C)
- Response Time: 0.12 seconds
- Burst Pressure: 10,000 psi
- Pressure Rating Range: -14.5 to 2000 psi
- Process Temperature: -40 to 248°F (-40 to 120°C)
- Ambient Operating Temperature (Without LCD): -40 to 185°F (-40 to 85°C); (With LCD module: -22 to 176°F / -30 to 80°C)
- Storage Temperature: -40 to 185°F (-40 to 85°C) without LCD; -22 to 176°F (-30 to 80°C) with LCD
- Humidity Rating (Manual): 5% – 98% RH at 104°F (40°C)
The enclosure is rated NEMA 4X (IP66) and explosion-proof. The transmitter supports a power supply of 11.9 to 45 VDC with an output signal of 4 to 20 mA / HART® Communication.
Measurement Ranges
The series offers multiple calibrated spans depending on the model configuration:
- 0 to 6 in w.c. (Calibrated Span: 0.6 to 30 in w.c.)
- 0 to 30 in w.c.
- 0 to 150 in w.c. (Calibrated Span: 1.5 to 150 in w.c.)
- 0 to 750 in w.c. (Calibrated Span: 7.5 to 750 in w.c.)
- 0 to 100 psi (Calibrated Span: 1 to 100 psi)
- 0 to 300 psi (Calibrated Span: 3 to 300 psi)
- 0 to 1000 psi
The transmitter provides a rangeability of up to 100:1.
Configuration Options
The Series 3100 is configurable across several dimensions including display options, process connections, and approvals. The standard wetted material is 316L SS stainless steel.
Housing & Display Options
- Standard Housing: Metal enclosure (Series 3100MP)
- LCD Option: A 5-digit LCD display is available on specific models, indicated by the "-LCD" suffix in model numbers.
- Note: Ambient operating temperature limits differ between units with and without the LCD module.
Approvals & Certifications
- Fm Approved (FM)
- HART® Communication Foundation
- Ce 0344 / CE
- AteX approved
- Note: A 316 SS housing is available only with WP approval.
Electrical & Process Connections
- Standard Electrical Connection: Two 1/2" female NPT conduit, screw terminal block.
- Load Resistance: 0 to 1500 Ω (HART® Communication requires 250 to 500 Ω).
- Process Connection: Standard models feature a 1/4" female NPT connection. Flanged connections are available via accessories.
Calibration & Configuration Features
The transmitter supports configuration of Range, Zero/Span, Unit, Tag, Dampening Time (0 to 60 seconds), Transfer Function, and DA Trim without a field calibrator. Custom calibration is available upon consultation with the factory.
- Custom Units: Supports in w.c., ft in w.c., mm in w.c., in Hg, psig, g/cm², kg/cm², MPa, Pa, kPa, bar, mbar, Torr, Atm, and mm Hg.
- Engineering Units: Volumetric flow (US gal/s, US gpm, l/min, ft³/h, etc.), Mass flow (kg/hr, lb/day, metric ton/hr), and Volume units are programmable if engineering unit mode is selected.
Accessories & Mounting
- A-630: Stainless steel angle type bracket with SS bolts
- A-631: Stainless steel flat type bracket with SS bolts
- BBV-1F: Flanged 3-valve block manifold
- BBV-22F: Flanged 5-valve block manifold
- DevCom2000: HART® Communication Protocol Software
- NIST Calibration: Available as an option.
Key Product Differences
The Series 3100 includes the Series-3100MP and Series-3100D families. The primary distinction between these series is physical dimensions:
- Series 3100MP Dimensions: Height: 7-31/32 [202.50], Width: 4-13/32 [112.00], Depth: 3-25/64 [86.00].
- Series 3100D Dimensions: Height: 7-37/64 [192.50], Width: 4-13/32 [112.00], Depth: 3-25/64 [86.00].
Both series share identical measurement ranges, accuracy specifications (±0.075% FS), and approval ratings within the documented model charts.
LCD vs. Non-LCD Models
Variants are distinguished by the presence of an LCD display:
- Non-LCD Models (e.g., 3100MP-2-FM-1-1): Do not include a local digital readout.
- LCD Models (e.g., 3100MP-2-FM-1-1-LCD): Include a 5-digit display for viewing Unit, %, mA, or Engineering units. These models have reduced ambient operating temperature limits (-22 to 176°F / -30 to 80°C) compared to non-LCD versions.
PDFs & Manuals